It is widely believed that computer-aided detection (CAD) schemes will eventually provide useful prescreening tools or """"""""second opinions"""""""" in radiology, to improve efficiency and accuracy in the detection of breast cancer-particularly subtle cancers at early stages in clinical screening environments. Existing CAD schemes typically provide their outputs by marking (cueing) suspicious locations on images for the reader's attention. Recent evidence, however, suggests that such cues can have detrimental effects when prompts are presented before readers have an opportunity to form unbiased impressions about the case findings. Current CAD schemes treat single images in isolation, whereas clinical mammograms obtain two separate views of both breasts (4 images). This project uses prospective interpretations of clinical mammograms to study the interface between a CAD system and the physician. Reader-performance studies will measure and compare radiologists' accuracy in detecting and localizing breast cancers, both with and without CAD cues, applying a concurrent analysis of performance that improves the statistical estimates of detection accuracy. Study 1 will use single-view mammograms to compare two different protocols for presenting CAD cues to readers, either prior to the case interpretation or only after an initial umprompted reading of each case. This study will investigate four different simulated CAD schemes that vary both the fractions of actual lesions prompted and the cueing rates for false-positive prompts. Study 2 will evaluate CAD prompting for prospective interpretations of complete, two-view mammograms (4-images). It will also investigate augmented CAD cues that code information about correlations between the two ipsilateral projections.

Agency
National Institute of Health (NIH)
Institute
National Cancer Institute (NCI)
Type
Research Project (R01)
Project #
5R01CA079754-03
Application #
6376955
Study Section
Special Emphasis Panel (ZRG1-DMG (02))
Program Officer
Liu, Guoying
Project Start
1999-07-01
Project End
2003-04-30
Budget Start
2001-05-01
Budget End
2002-04-30
Support Year
3
Fiscal Year
2001
Total Cost
$324,852
Indirect Cost
Name
University of Pittsburgh
Department
Radiation-Diagnostic/Oncology
Type
Schools of Medicine
DUNS #
053785812
City
Pittsburgh
State
PA
Country
United States
Zip Code
15213
Mello-Thoms, Claudia; Hardesty, Lara; Sumkin, Jules et al. (2005) Effects of lesion conspicuity on visual search in mammogram reading. Acad Radiol 12:830-40
Zheng, Bin; Chakraborty, Dev P; Rockette, Howard E et al. (2005) A comparison of two data analyses from two observer performance studies using Jackknife ROC and JAFROC. Med Phys 32:1031-4
Zheng, Bin; Swensson, Richard G; Golla, Sara et al. (2004) Detection and classification performance levels of mammographic masses under different computer-aided detection cueing environments. Acad Radiol 11:398-406
Mello-Thoms, Claudia (2003) Perception of breast cancer: eye-position analysis of mammogram interpretation. Acad Radiol 10:4-12
Mello-Thoms, Claudia; Dunn, Stanley M; Nodine, Calvin F et al. (2003) The perception of breast cancers--a spatial frequency analysis of what differentiates missed from reported cancers. IEEE Trans Med Imaging 22:1297-306
Mello-Thoms, Claudia; Dunn, Stanley; Nodine, Calvin F et al. (2002) The perception of breast cancer: what differentiates missed from reported cancers in mammography? Acad Radiol 9:1004-12
Swensson, R G; King, J L; Gur, D (2001) A constrained formulation for the receiver operating characteristic (ROC) curve based on probability summation. Med Phys 28:1597-609
Swensson, R G; King, J L; Good, W F et al. (2000) Observer variation and the performance accuracy gained by averaging ratings of abnormality. Med Phys 27:1920-33