Objective: The overall objective is to develop a field-emission x-ray source with high spatial coherence, and a phase-contrast imaging technique for clinical applications. Challenges: Current phase-contrast x-ray techniques generally require highly monochromatic, synchrotron-based, plane-wave radiation and sophisticated x-ray optics, so their clinical application is limited. Theoretical analysis and experimental studies have demonstrated the clinical feasibility of in-line phase-contrast imaging using a small, yet very bright x-ray source. However, these requirements cannot be met by the conventional sources. A novel field-emission x-ray source is therefore proposed. Methods: Cutting-edge nanotechnology will be applied to fabricate a super tip for the electron gun of the x-ray source. The super tip will be integrated with a miniature vacuum pump and an ion mirror to avoid contamination and the ion bombardment of the electron emitter. The anticipated end product is an x-ray source with a small focal spot (less than 0.025 mm), and at the same time, a high tube current (greater than 25mA), thus providing high spatial coherence. The field-emission x-ray source developed in the early phase of this project will be used to facilitate a new phase contrast imaging technique. The innovative system design is based on the in-line holography principle, acquiring phase contrast under large attenuation (a common clinical condition); therefore has the following clinically friendly features: (1) The source-to-detector distance of the system is no more than 1 meter; (2) the relative phase-contrast factor is up to 0.015 at 20 Ip/mm; (3) the detector quantum efficiency, radiation dose, and exposure time of the phase-contrast system are equivalent to that of the current state-of-art systems; and (4) the contrast-detail detectability is significantly improved due to the edge enhancement introduced by phase-contrast. Comprehensive measurements will be conducted to characterize the performance of the proposed system under clinical conditions. That includes objective measurements of resolution, contrast and quantum efficiency, and observer-based subjective measurements. The end product of the proposed research is a prototype phase-contrast imaging system for clinical applications. Summary: The proposed research, with its innovative field emission source and a new in-line x-ray imaging system, overcomes the major technical """"""""roadblocks"""""""" in clinical applications of phase-contrast x-ray imaging.

Agency
National Institute of Health (NIH)
Institute
National Cancer Institute (NCI)
Type
Research Project (R01)
Project #
5R01CA104773-04
Application #
7117673
Study Section
Diagnostic Imaging Study Section (DMG)
Program Officer
Farahani, Keyvan
Project Start
2003-09-30
Project End
2009-08-31
Budget Start
2006-09-01
Budget End
2009-08-31
Support Year
4
Fiscal Year
2006
Total Cost
$398,929
Indirect Cost
Name
University of Oklahoma Norman
Department
Engineering (All Types)
Type
Schools of Engineering
DUNS #
848348348
City
Norman
State
OK
Country
United States
Zip Code
73019
Donovan, Molly; Zhang, Da; Liu, Hong (2009) Step by step analysis toward optimal MTF algorithm using an edge test device. J Xray Sci Technol 17:1-15
Zhang, Da; Donovan, Molly; Fajardo, Laurie L et al. (2008) Preliminary feasibility study of an in-line phase contrast X-ray imaging prototype. IEEE Trans Biomed Eng 55:2249-57
Da, Zhang; Donovan, Molly; Wu, Xizeng et al. (2008) A convenient alignment approach for x-ray imaging experiments based on laser positioning devices. Med Phys 35:4907-10
Gnyawali, Surya C; Chen, Yicho; Wu, Feng et al. (2008) Temperature measurement on tissue surface during laser irradiation. Med Biol Eng Comput 46:159-68
Wu, Xizeng; Liu, Hong (2007) Clarification of aspects in in-line phase-sensitive x-ray imaging. Med Phys 34:737-43
Wang, Xingwei; Li, Shibo; Liu, Hong et al. (2006) A computer-aided method to expedite the evaluation of prognosis for childhood acute lymphoblastic leukemia. Technol Cancer Res Treat 5:429-36
Chen, Wei R; Huang, Zheng; Korbelik, Mladen et al. (2006) Photoimmunotherapy for cancer treatment. J Environ Pathol Toxicol Oncol 25:281-91
Wu, Xizeng; Liu, Hong; Yan, Aimin (2005) X-ray phase-attenuation duality and phase retrieval. Opt Lett 30:379-81
Tang, David; Li, Yuhua; Wong, Jessica et al. (2005) Characteristics of a charged-coupled-device-based optical mapping system for the study of cardiac arrhythmias. J Biomed Opt 10:024009
Wu, Xizeng; Liu, Hong (2005) Phase-space formulation for phase-contrast x-ray imaging. Appl Opt 44:5847-54

Showing the most recent 10 out of 12 publications