Lung cancer is one of the leading causes of death in the United States, surpassing breast, prostate, colon, and cervical cancers combined. One of the keys to improving the prognosis of lung cancer is early detection of small solitary lung nodules in chest radiographs, a task highly limited by the presence of anatomical variations in the image and by perceptual visualization processes. This project proposes a new method, Bi-plane Correlation Imaging (BC1), for improved detection of subtle lung nodules. The method involves the utilization of angular information in conjunction with digital acquisition and computer-assisted diagnosis (CAD) to cost-effectively reduce the degrading influence of anatomical variations with little or no increase in the patient dose. In BCI, two digital images of the chest are acquired within a short time interval from slightly different posterior projections. The image data are incorporated into an enhanced CAD algorithm in which nodules present in the thoracic cavity are detected by examining the geometrical correlation of the detected signals in the two views. Angular information minimizes the undesirable influence of anatomical noise by identifying and positively reinforcing the nodule signals, while CAD provides a complete search of the image data. The expected high sensitivity/specificity of the method has the potential to change the current state of practice, perhaps leading to a preventive lung cancer screening program for high-risk populations. The project focuses on implementation and clinical evaluation of BCI. Initially, steps will be taken to streamline the optimum acquisition and processing methods for BCI using phantom images. A dedicated imaging system will then be developed capable of high-speed bi-plane imaging of the chest. The system will be used to acquire bi-plane paired digital radiographs from 150 high-risk human subjects with confirmed lung nodules and 75 normals. The data will be processed according to an optimized BCI scheme based on the spatial correlation of CAD-identified lesions in the two views. A graphical user interface will be developed for the diagnostic evaluation of the method. A method and a graphical user interface will also be developed for stereoscopic presentation of bi-plane images. The comparative performance of single image and dual image detection of lung nodules in the collected database with and without the BCI and stereoscopic display will be evaluated. The findings will be used to substantiate the capability of BCI for improving the early detection of lung nodules and to optimize its performance on actual clinical cases.

Agency
National Institute of Health (NIH)
Institute
National Cancer Institute (NCI)
Type
Research Project (R01)
Project #
5R01CA109074-04
Application #
7266296
Study Section
Diagnostic Imaging Study Section (DMG)
Program Officer
Menkens, Anne E
Project Start
2004-09-24
Project End
2010-06-30
Budget Start
2007-07-11
Budget End
2010-06-30
Support Year
4
Fiscal Year
2007
Total Cost
$269,406
Indirect Cost
Name
Duke University
Department
Radiation-Diagnostic/Oncology
Type
Schools of Medicine
DUNS #
044387793
City
Durham
State
NC
Country
United States
Zip Code
27705
Samei, Ehsan; Majdi-Nasab, Nariman; Dobbins 3rd, James T et al. (2012) Biplane correlation imaging: a feasibility study based on phantom and human data. J Digit Imaging 25:137-47
Samei, Ehsan; Ranger, Nicole T; MacKenzie, Alistair et al. (2009) Effective DQE (eDQE) and speed of digital radiographic systems: an experimental methodology. Med Phys 36:3806-17
Chawla, Amarpreet S; Boyce, Sarah; Washington, Lacey et al. (2009) Design and Development of a New Multi-Projection X-Ray System for Chest Imaging. IEEE Trans Nucl Sci 56:36-45
Chawla, Amarpreet S; Samei, Ehsan; Saunders, Robert S et al. (2008) A mathematical model platform for optimizing a multiprojection breast imaging system. Med Phys 35:1337-45
Samei, Ehsan; Ranger, Nicole T; MacKenzie, Alistair et al. (2008) Detector or system? Extending the concept of detective quantum efficiency to characterize the performance of digital radiographic imaging systems. Radiology 249:926-37
Chawla, Amarpreet S; Samei, Ehsan; Saunders, Robert et al. (2007) Effect of dose reduction on the detection of mammographic lesions: a mathematical observer model analysis. Med Phys 34:3385-98
Samei, Ehsan; Stebbins, Stanton A; Dobbins 3rd, James T et al. (2007) Multiprojection correlation imaging for improved detection of pulmonary nodules. AJR Am J Roentgenol 188:1239-45
Ranger, Nicole T; Samei, Ehsan; Dobbins 3rd, James T et al. (2007) Assessment of detective quantum efficiency: intercomparison of a recently introduced international standard with prior methods. Radiology 243:785-95
Dobbins 3rd, James T; Samei, Ehsan; Ranger, Nicole T et al. (2006) Intercomparison of methods for image quality characterization. II. Noise power spectrum. Med Phys 33:1466-75
Samei, Ehsan; Ranger, Nicole T; Dobbins 3rd, James T et al. (2006) Intercomparison of methods for image quality characterization. I. Modulation transfer function. Med Phys 33:1454-65