Stereotactic body radiation therapy (SBRT) has become an effective treatment paradigm for early stage non- small cell lung cancer (NSCLC) patients. The success of lung SBRT is determined by the accuracy of target localization as well as sparing of critical normal structures. Intrafraction verification is critical for lung SBRT due to its tight PTV margin, high fractional dse with small fraction number, and long treatment time. Purdie et al showed that lung tumor intrafraction motion increases with treatment time, and can be over 1cm for SBRT. Zhao et al reported a maximal drop of PTV coverage from 95% to 78% in lung SBRT using 5mm margin due to intrafraction motion. The accuracy of using kV fluoroscopy and MV cine imaging for intrafraction verification is limited especially for small tumors due to overlaying structures in 2 images. Conventional CBCT also has limited application for intrafraction verification due to large scanning angle, long acquisition time, high imaging dose and limited mechanical clearance. By far, neither 3D nor 4D volumetric x-ray imaging techniques are available for target verification on-the-fly during actual treatment delivery. This research plan proposes to develop a Limited-angle Intrafraction Verification (LIVE) system for fast 4D verification during arc treatment delivery or in between 3D/IMRT beams. The long term goal of the LIVE system is to improve the tumor control and reduce normal tissue toxicity for lung SBRT by substantially reducing the treatment errors caused by intrafraction motion and improving the accuracy of ART.
The specific aims of the proposal are: 1) Build the LIVE system by developing novel image acquisition, sorting, kV-MV aggregation and reconstruction techniques. 2) Optimize the accuracy, efficiency and imaging dose of LIVE through respiratory motion modeling, novel acceleration strategies, and XCAT and Monte Carlo (MC) simulation. 3) Evaluate the LIVE system for IGRT and ART. LIVE creatively combined a number of new technologies being developed for fast intrafraction verification: 1) limited-angle kV-MV image acquisition; 2) automatic projection sorting based on Fourier Transformation of projections; 3) kV-MV aggregation using linear fitting, virtual mono-energetic and dual CT techniques; 4) 4D- and phase-matched digital tomosynthesis (DTS) and prior knowledge based CBCT reconstruction methods; 5) respiratory motion modeling; 6) adaptive reconstruction strategy; and 7) new acceleration strategies. Parameters of the LIVE system, including beam energy, fluence, kV-MV imaging sequence, number of kV-MV projections, and scan angle will be optimized for different tumor sizes and locations through 4D digital extended cardiac-torso phantom (XCAT) and Monte Carlo (MC) simulation. MC will also be used to evaluate the imaging dose. The effectiveness of LIVE system for IGRT and ART applications will be quantitatively evaluated through phantom studies using the CIRS dynamic thorax motion phantom and patient studies using lung patient CBCT and MV cine image data collected in a retrospective study.

Public Health Relevance

The LIVE system can substantially reduce the treatment errors and improve the accuracy of dose delivery estimation in lung SBRT, which paves the road to further margin reduction and dose escalation. As a result, LIVE can potentially improve the tumor local control and reduce the normal tissue toxicity for all patients under lung SBRT treatments. Last but not least, the LIVE system also has great potential for intrafraction verification of stereotactic treatments of other clinical sites, including liver, prostate, breast, brain, and spine.

Agency
National Institute of Health (NIH)
Institute
National Cancer Institute (NCI)
Type
Research Project (R01)
Project #
1R01CA184173-01A1
Application #
8818761
Study Section
Radiation Therapeutics and Biology Study Section (RTB)
Program Officer
Deye, James
Project Start
2014-12-08
Project End
2018-11-30
Budget Start
2014-12-08
Budget End
2015-11-30
Support Year
1
Fiscal Year
2015
Total Cost
$341,822
Indirect Cost
$124,748
Name
Duke University
Department
Radiation-Diagnostic/Oncology
Type
Schools of Medicine
DUNS #
044387793
City
Durham
State
NC
Country
United States
Zip Code
27705
Harris, Wendy; Wang, Chunhao; Yin, Fang-Fang et al. (2018) A Novel method to generate on-board 4D MRI using prior 4D MRI and on-board kV projections from a conventional LINAC for target localization in liver SBRT. Med Phys 45:3238-3245
Zhang, Yawei; Deng, Xinchen; Yin, Fang-Fang et al. (2018) Image acquisition optimization of a limited-angle intrafraction verification (LIVE) system for lung radiotherapy. Med Phys 45:340-351
Dubey, Abhishek; Iliopoulos, Alexandros-Stavros; Sun, Xiaobai et al. (2018) Iterative inversion of deformation vector fields with feedback control. Med Phys 45:3147-3160
Gao, Hao; Zhang, Yawei; Ren, Lei et al. (2018) Principal component reconstruction (PCR) for cine CBCT with motion learning from 2D fluoroscopy. Med Phys 45:167-177
Chen, Yingxuan; Yin, Fang-Fang; Zhang, Yawei et al. (2018) Low dose CBCT reconstruction via prior contour based total variation (PCTV) regularization: a feasibility study. Phys Med Biol 63:085014
Wang, Chunhao; Yin, Fang-Fang; Segars, W P et al. (2017) Development of a Computerized 4-D MRI Phantom for Liver Motion Study. Technol Cancer Res Treat :1533034617723753
Zhang, Lei; Zhang, Yawei; Zhang, You et al. (2017) Markerless Four-Dimensional-Cone Beam Computed Tomography Projection-Phase Sorting Using Prior Knowledge and Patient Motion Modeling: A Feasibility Study. Cancer Transl Med 3:185-193
Harris, Wendy; Zhang, You; Yin, Fang-Fang et al. (2017) Estimating 4D-CBCT from prior information and extremely limited angle projections using structural PCA and weighted free-form deformation for lung radiotherapy. Med Phys 44:1089-1104
Harris, Wendy; Yin, Fang-Fang; Wang, Chunhao et al. (2017) Accelerating volumetric cine MRI (VC-MRI) using undersampling for real-time 3D target localization/tracking in radiation therapy: a feasibility study. Phys Med Biol 63:01NT01
Zhang, You; Ren, Lei; Vergalasova, Irina et al. (2017) Clinical Study of Orthogonal-View Phase-Matched Digital Tomosynthesis for Lung Tumor Localization. Technol Cancer Res Treat :1533034617705716

Showing the most recent 10 out of 16 publications