Integrated Approaches to close the loop in Type 1 diabetes. The RFA 08-012 emphasizes closing the loop in type 1 diabetes mellitus (T1DM), an endeavor that will depend on developing physiological models that will evaluate the reasons for glycemic variability using state of the art technologic approaches so that continuous subcutaneous insulin infusion (CSII) algorithms are better informed. The physiology studies need to be directed towards understanding the impact of variability introduced by circadian and intra-individual differences in post prandial insulin action, variability in the timing and rate of appearance of ingested carbohydrates into the systemic circulation and variability introduced by changes in physical activity. Using innovative specific activity clamps to minimize non steady state errors, we have recently developed and validated a triple tracer technique to measure post prandial peripheral and hepatic insulin action and rate of appearance of meal derived glucose. We have also developed and validated tools (eg., accelerometers, physical activity monitoring systems) to accurately capture daily physical activity. In this context, and utilizing the above techniques, the following specific aims will be addressed: 1) We will determine whether circadian pattern of post prandial insulin action and meal glucose appearance occurs in T1DM and the extent to which it differs from nondiabetic healthy subjects. We will also take this opportunity to further develop and validate a novel single tracer method to measure post prandial glucose kinetics. 2) We will explore if gastric emptying rate can predict post prandial meal glucose appearance, insulin action and 24 hour glucose variability in T1DM. To do so, we will screen for abnormalities in gastric emptying then use the tripe tracer method (or single tracer model if validated in aim 1) to determine if asymptomatic changes in gastric emptying are accompanied by changes in the timing and systemic rate appearance of ingested glucose and if so, the extent to which changes in the pattern of meal appearance predict post prandial hyperglycemia and glucose variability as measured using CGM parameters. This is an important variable to consider since abnormal gastric motility is frequently observed in asymptomatic individuals with T1DM. 3) We will evaluate the impact of low and moderate intensity physical activity on glucose variability, post prandial meal glucose appearance and insulin action in T1DM. To do so, we will assess the impact of low and moderate intensity exercise (measured by accelerometers) on glucose variability using CGM parameters (high and low blood glucose indices), meal glucose appearance and post prandial insulin action. We will take this opportunity to further modify tracer technique if necessary to clamp specific activity in order to accurately estimate insulin action in the post prandial state. Summary and Significance: Glucose variability and frequent hypoglycemia are major factors that limit optimal subcutaneous insulin delivery in T1DM. In this application, we propose to utilize and further innovate existing cutting edge techniques to develop a physiological model whereby daily variations in post prandial insulin action, gastric motility and physical activity captured with precise physical activity monitoring systems, e.g., accelerometers, are integrated to facilitate development of a model predictive control algorithm of individualized """"""""closed loop system"""""""" of insulin delivery.

Public Health Relevance

The insulin pump and the glucose sensor have had limited impact on control of blood sugar and quality of life in type 1 diabetes mellitus (T1DM). This is because of limited knowledge of the effects of daily variation in efficiency of insulin action, stomach emptying capacity and physical activity on daily fluctuations in blood sugar in T1DM. Using innovative and cutting edge technologies, we will investigate the effects of all of these factors on sugar metabolism and fluctuations in blood sugar in people with T1DM on the insulin pump and glucose sensor and simultaneously initiate the use of new technology such as highly accurate accelerometers to capture physical activity. We believe that information obtained from our research will result in the development of a first generation endocrine artificial pancreas.

Agency
National Institute of Health (NIH)
Institute
National Institute of Diabetes and Digestive and Kidney Diseases (NIDDK)
Type
Research Project (R01)
Project #
5R01DK085516-03
Application #
8136077
Study Section
Special Emphasis Panel (ZDK1-GRB-2 (O2))
Program Officer
Arreaza-Rubin, Guillermo
Project Start
2009-09-30
Project End
2014-08-31
Budget Start
2011-09-01
Budget End
2012-08-31
Support Year
3
Fiscal Year
2011
Total Cost
$631,882
Indirect Cost
Name
Mayo Clinic, Rochester
Department
Type
DUNS #
006471700
City
Rochester
State
MN
Country
United States
Zip Code
55905
Basu, Ananda; Joshi, Nisha; Miles, John et al. (2018) Paradigm Shifts in Nocturnal Glucose Control in Type 2 Diabetes. J Clin Endocrinol Metab 103:3801-3809
Ozaslan, Basak; Patek, Stephen D; Grabman, Jesse H et al. (2018) Body Mass Index Effect on Differing Responses to Psychological Stress in Blood Glucose Dynamics in Patients With Type 1 Diabetes. J Diabetes Sci Technol 12:657-664
Cramer, Angela M; Scalzo, Patricia; Bach, Sarah M et al. (2017) Patient- and Provider-Centered Design of an Outpatient Diabetes Technology Clinic. J Diabetes Sci Technol 11:499-505
Brown, Sue A; Breton, Marc D; Anderson, Stacey M et al. (2017) Overnight Closed-Loop Control Improves Glycemic Control in a Multicenter Study of Adults With Type 1 Diabetes. J Clin Endocrinol Metab 102:3674-3682
Gonder-Frederick, Linda A; Grabman, Jesse H; Kovatchev, Boris et al. (2016) Is Psychological Stress a Factor for Incorporation Into Future Closed-Loop Systems? J Diabetes Sci Technol 10:640-6
Cartee, Amanda K; Owens, Lisa A; Lahr, Brian D et al. (2016) Incidence of Type 1 Diabetes Is Not Increasing in a Population-Based Cohort in Olmsted County, Minnesota, USA. Mayo Clin Proc 91:1066-73
Dadlani, Vikash; Kudva, Yogish C (2016) Continuous Glucose Monitor Use and Accuracy in Hospitalized Patients. Diabetes Technol Ther 18:449-51
Cobelli, Claudio; Schiavon, Michele; Dalla Man, Chiara et al. (2016) Interstitial Fluid Glucose Is Not Just a Shifted-in-Time but a Distorted Mirror of Blood Glucose: Insight from an In Silico Study. Diabetes Technol Ther 18:505-11
Basu, Ananda; Veettil, Sona; Dyer, Roy et al. (2016) Direct Evidence of Acetaminophen Interference with Subcutaneous Glucose Sensing in Humans: A Pilot Study. Diabetes Technol Ther 18 Suppl 2:S243-7
Dadlani, Vikash; Kudva, Yogish C (2016) Role of Automation/Technology in Day-to-Day Diabetes Care. Diabetes Technol Ther 18:273-5

Showing the most recent 10 out of 41 publications