Cancer biologists are currently exploring the role that in vivo imaging may play in studying small animal models of cancer. Imaging technologies can be used to visualize and measure morphology, physiology, metabolism, as well as specific molecular targets and processes. The non-invasive nature of imaging permits multiple studies within a single experimental subject and also provides a natural bridge into the clinical environment. Positron Emission Tomography (PET) is one of the imaging modalities under consideration, and in recent years, our group, and others, have developed high-resolution small animal PET scanners for this purpose. Several of these small animal PET systems are now being used in cancer applications including basic studies of tumor biology, new probes for tumor detection and in vivo monitoring of therapeutic effect. MicroPET II is a second generation small animal PET scanner designed to achieve 1 mm (1 pL) spatial resolution in vivo with a sensitivity of - 2%. This compares with 1.8 mm (8 pL) resolution and 0.5% sensitivity in the initial prototype microPET. In this proposal, a rigorous evaluation of this new instrument will performed, and data corrections implemented to ensure that accurate quantification is achieved in vivo. Three important issues in small animal PET imaging also will be addressed: i) How reproducible are in vivo microPET measurements? ii) What are the limits of detection for microPET imaging? iii) Can the blood input function be obtained non-invasively in the mouse by rapid dynamic imaging? Finally, the high spatial resolution of microPET II will be used to examine the degrading effects of positron range in longer-lived radionuclides that are of interest for molecular imaging (for example 1-1 24, Br-76) but which emit medium to high energy positrons. MicroPET II is designed to be a powerful new tool for cancer researchers. The careful evaluation of this system along with the implementation of quantitative imaging and studies of reproducibility, detection sensitivity and positron range effects, will lay a firm foundation on which to base future studies in mouse models of cancer using microPET II and other similar small animal PET systems.

Agency
National Institute of Health (NIH)
Institute
National Institute of Biomedical Imaging and Bioengineering (NIBIB)
Type
Research Project (R01)
Project #
9R01EB000561-08
Application #
6543607
Study Section
Diagnostic Imaging Study Section (DMG)
Program Officer
Pastel, Mary
Project Start
1996-09-01
Project End
2005-08-31
Budget Start
2002-09-01
Budget End
2003-08-31
Support Year
8
Fiscal Year
2002
Total Cost
$319,657
Indirect Cost
Name
University of California Davis
Department
Biomedical Engineering
Type
Schools of Engineering
DUNS #
094878337
City
Davis
State
CA
Country
United States
Zip Code
95618
Stickel, Jennifer R; Qi, Jinyi; Cherry, Simon R (2007) Fabrication and characterization of a 0.5-mm lutetium oxyorthosilicate detector array for high-resolution PET applications. J Nucl Med 48:115-21
Abbey, Craig K; Borowsky, Alexander D; Gregg, Jeffery P et al. (2006) Preclinical imaging of mammary intraepithelial neoplasia with positron emission tomography. J Mammary Gland Biol Neoplasia 11:137-49
Yang, Yongfeng; Dokhale, Purushottam A; Silverman, Robert W et al. (2006) Depth of interaction resolution measurements for a high resolution PET detector using position sensitive avalanche photodiodes. Phys Med Biol 51:2131-42
Cardiff, Robert D; Anver, Miriam R; Boivin, Gregory P et al. (2006) Precancer in mice: animal models used to understand, prevent, and treat human precancers. Toxicol Pathol 34:699-707
Yang, Yongfeng; Rendig, Stephen; Siegel, Stefan et al. (2005) Cardiac PET imaging in mice with simultaneous cardiac and respiratory gating. Phys Med Biol 50:2979-89
Judenhofer, Martin S; Pichler, Bernd J; Cherry, Simon R (2005) Evaluation of high performance data acquisition boards for simultaneous sampling of fast signals from PET detectors. Phys Med Biol 50:29-44
Yang, Yongfeng; Tai, Yuan-Chuan; Siegel, Stefan et al. (2004) Optimization and performance evaluation of the microPET II scanner for in vivo small-animal imaging. Phys Med Biol 49:2527-45
Abbey, Craig K; Borowsky, Alexander D; McGoldrick, Erik T et al. (2004) In vivo positron-emission tomography imaging of progression and transformation in a mouse model of mammary neoplasia. Proc Natl Acad Sci U S A 101:11438-43
Tai, Yuan-Chuan; Chatziioannou, Arion F; Yang, Yongfeng et al. (2003) MicroPET II: design, development and initial performance of an improved microPET scanner for small-animal imaging. Phys Med Biol 48:1519-37
Rubins, Daniel J; Melega, William P; Lacan, Goran et al. (2003) Development and evaluation of an automated atlas-based image analysis method for microPET studies of the rat brain. Neuroimage 20:2100-18