Non-invasive glucose monitoring is desired to reduce the pain of blood sampling, which is an important step toward improved control of blood glucose for diabetics. Poor control results in debilitating complications, but the bother associated with testing typically leads to low patient compliance with recommended monitoring frequencies. The concept of implantable fluorescent sensors that can be monitored transdermally would be an attractive solution to the problem, but many obstacles to practical use have been identified. This work aims to use polyelectrolyte microcapsules to overcome drawbacks of previously proposed systems. Methods for fabricating these structures have been developed over the past few years, with precision control over mechanical and chemical properties, thus, """"""""tuning"""""""" of the structures to fit different applications may be possible. Recent work has produced fundamental knowledge on the properties of these nanostructured capsules, yet there has been little reported by way of practical application. Since biomedical applications have not been pursued, no work has been done to assess the biocompatibility of the materials used. An interdisciplinary research team will evaluate the potential for polyelectrolyte microcapsules to function as carriers for fluorescence sensing chemistry using an integrative approach to sensor design that considers material, chemical, optical, and biological properties. The work will clarify basic questions regarding the process of encapsulation, then use these data to engineer sensor properties that will possess clinically relevant response characteristics. The stability of the structures will be assessed over time in increasingly physiological conditions, and methods to overcome problems with fouling and enzyme degradation will be identified to allow progress to continue. Finally, the biocompatibility of the materials used will be studied from molecule to device level, in vitro and in vivo, to determine baseline host response and risk factors for device failure.

Agency
National Institute of Health (NIH)
Institute
National Institute of Biomedical Imaging and Bioengineering (NIBIB)
Type
Research Project (R01)
Project #
5R01EB000739-03
Application #
6779792
Study Section
Special Emphasis Panel (ZRG1-SSS-F (02))
Program Officer
Moy, Peter
Project Start
2002-09-30
Project End
2007-08-31
Budget Start
2004-09-01
Budget End
2005-08-31
Support Year
3
Fiscal Year
2004
Total Cost
$259,189
Indirect Cost
Name
Louisiana Tech University
Department
Biomedical Engineering
Type
Schools of Engineering
DUNS #
069746725
City
Ruston
State
LA
Country
United States
Zip Code
71272
Long, Ruiqi; McShane, Mike (2012) High-throughput spectral system for interrogation of dermally-implanted luminescent sensors. Conf Proc IEEE Eng Med Biol Soc 2012:2351-4
Long, Ruiqi; McShane, Mike (2012) Design of an optical system for interrogation of implanted luminescent sensors and verification with silicone skin phantoms. IEEE Trans Biomed Eng 59:2459-65
Chaudhary, Ayesha; Harma, Harri; Hanninen, Pekka et al. (2011) Glucose response of near-infrared alginate-based microsphere sensors under dynamic reversible conditions. Diabetes Technol Ther 13:827-35
Collier, Bradley B; Singh, Saurabh; McShane, Mike (2011) Microparticle ratiometric oxygen sensors utilizing near-infrared emitting quantum dots. Analyst 136:962-7
Singh, Saurabh; McShane, Mike (2011) Role of porosity in tuning the response range of microsphere-based glucose sensors. Biosens Bioelectron 26:2478-83
Chaudhary, Ayesha; McShane, Michael J; Srivastava, Rohit (2010) Glucose response of dissolved-core alginate microspheres: towards a continuous glucose biosensor. Analyst 135:2620-8
Long, Ruiqi; McShane, Mike (2010) High-efficiency optical systems for interrogation of dermally-implanted sensors. Conf Proc IEEE Eng Med Biol Soc 2010:1033-6
Park, Jaebum; McShane, Michael J (2010) Dual-function nanofilm coatings with diffusion control and protein resistance. ACS Appl Mater Interfaces 2:991-7
Long, Ruiqi; McShane, Mike (2010) Three-dimensional, multiwavelength Monte Carlo simulations of dermally implantable luminescent sensors. J Biomed Opt 15:027011
Singh, Saurabh; McShane, Mike (2010) Enhancing the longevity of microparticle-based glucose sensors towards 1 month continuous operation. Biosens Bioelectron 25:1075-81

Showing the most recent 10 out of 47 publications