The long-term goal of this project is to develop an advanced mu/SPECT/CT molecular imaging technology including a state-of-the-art innovative mu/SPECT system and accurate quantitative pinhole and multi-pinhole SPECT imaging techniques that provide ultra-high-resolution down to approximately 0.5 mm and detection efficiency on the order of 2 cps/mu/Ci. To evaluate the novel fSPECT/CT technology, we propose to perform simulations as well as experimental phantom and small animal imaging studies. To respond to the main concern of the reviewers that the previous proposal was too diffuse, we have refocused the research by redesigning the mu/SPECT system configuration with a fixed-angled detector assembly without going through the prototype stage, constructing the unique 'angled detector module assembly' with the latest high performance but robust detector technologies, eliminating the longitudinal tomography study using planar multi-pinhole imaging with standard gamma camera system, deleting two small animal imaging studies to focus on the most important application to imaging of plaques in mice, and switching to a simpler transgenic mouse model with stable and unstable plaques. Also, the proposal is strengthened by additional preliminary data from multi-pinhole image reconstruction, Monte Carlo simulation of pinhole SPECT data, and plaque imaging in transgenic mice using 99mTc Hynic-Annexin V. The team of investigators is streamlined with 2 groups of investigators and 3 key consultants with relevant areas of expertise. The revised specific aims are: (1) to develop a state-of-the-art 'angled' detector module and single and multiple pinhole collimation and an x-ray imaging device for use in the mu/SPECT/CT systems in Aim #5, (2) to develop simulation software for 3D SPECT imaging that models performance characteristics of the scintillation camera modules, design parameters of single and multiple pinhole collimator, and the SPECT system geometry and configuration, (3) to develop 3D quantitative SPECT image reconstruction methods for single and multiple pinhole SPECT with correction of attenuation, scatter and collimator response for accurate absolute quantitation of radioactivity in vivo, (4) to develop simple, accurate and robust calibration methods for single and multi-pinhole SPECT systems, (5) to develop a prototype mu/SPECT/CT system that includes two angled detector assemblies developed in Aim #1 and an existing mu/CT system that will be mounted on a commercial grade CT gantry, and (6) to evaluate the pinhole SPECT imaging techniques and the mu/SPECT/CT system in imaging stable and vulnerable plaques in a transgenic mouse model using 99mTc labeled Annexin-V.

Agency
National Institute of Health (NIH)
Institute
National Institute of Biomedical Imaging and Bioengineering (NIBIB)
Type
Research Project (R01)
Project #
5R01EB001558-04
Application #
7275971
Study Section
Special Emphasis Panel (ZRG1-SBIB-F (02))
Program Officer
Haller, John W
Project Start
2004-09-30
Project End
2011-04-30
Budget Start
2007-09-01
Budget End
2011-04-30
Support Year
4
Fiscal Year
2007
Total Cost
$475,121
Indirect Cost
Name
Johns Hopkins University
Department
Radiation-Diagnostic/Oncology
Type
Schools of Medicine
DUNS #
001910777
City
Baltimore
State
MD
Country
United States
Zip Code
21218
Mok, Greta S P; Yu, Jianhua; Du, Yong et al. (2012) Evaluation of a multi-pinhole collimator for imaging small animals with different sizes. Mol Imaging Biol 14:60-9
Mok, Greta S P; Tsui, Benjamin M W; Beekman, Freek J (2011) The effects of object activity distribution on multiplexing multi-pinhole SPECT. Phys Med Biol 56:2635-50
de Kemp, Robert A; Epstein, Frederick H; Catana, Ciprian et al. (2010) Small-animal molecular imaging methods. J Nucl Med 51 Suppl 1:18S-32S
Mok, Greta S P; Du, Yong; Wang, Yuchuan et al. (2010) Development and validation of a Monte Carlo simulation tool for multi-pinhole SPECT. Mol Imaging Biol 12:295-304
Tsui, Benjamin M W; Kraitchman, Dara L (2009) Recent advances in small-animal cardiovascular imaging. J Nucl Med 50:667-70
Xu, Jingyan; Mahesh, Mahadevappa; Tsui, Benjamin M W (2009) Is iterative reconstruction ready for MDCT? J Am Coll Radiol 6:274-6
Chen, Chia-Lin; Wang, Yuchuan; Lee, Jason J S et al. (2009) Toward quantitative small animal pinhole SPECT: assessment of quantitation accuracy prior to image compensations. Mol Imaging Biol 11:195-203
Mok, Greta S P; Wang, Yuchuan; Tsui, Benjamin M W (2009) Quantification of the Multiplexing Effects in Multi-Pinhole Small Animal SPECT: A Simulation Study. IEEE Trans Nucl Sci 56:2636-2643
Chen, Chia-Lin; Wang, Yuchuan; Lee, Jason J S et al. (2008) Integration of SimSET photon history generator in GATE for efficient Monte Carlo simulations of pinhole SPECT. Med Phys 35:3278-84
Gabrielson, Kathleen L; Mok, Greta S P; Nimmagadda, Srihdar et al. (2008) Detection of dose response in chronic doxorubicin-mediated cell death with cardiac technetium 99m annexin V single-photon emission computed tomography. Mol Imaging 7:132-8

Showing the most recent 10 out of 11 publications