Interactive, Image-Guided Surgery (IIGS) is a technique in which the three-dimensional position of any surgical instrument is tracked and that position is displayed on preoperatively obtained tomograms. The research proposed in this project is to extend beyond the initial application of IIGS, intracranial neurosurgery, and to expand the image information provided to the surgeon. The extension of this process will be to spinal surgeries. In order to apply IIGS techniques to spinal applications new forms of registration and display will have to be developed. Inherent in this process will be the development of automatic and semi-automatic segmentation techniques for structures in and about the spine. Intracranial IIGS has led to reduced damage to healthy tissue, smaller incisions, more complete resections and reduced time of surgery. Given the huge number of spinal surgeries relative to intracranial surgeries, if IIGS can provide the same advantages to spinal surgery as it does to intracranial surgeries, the rewards to health care would be enormous. The proposed expansion of the image information includes both vascular and realtime imaging formats. The vascular images will include both conventional projection angiograms and tomographic vascular images such as MRA and CTA. By using realtime imaging techniques such as endoscopy and B- Mode ultrasound in conjunction with tomographic image sets, the advantages of each may be preserved and the drawbacks to each mitigated.

Agency
National Institute of Health (NIH)
Institute
National Institute of General Medical Sciences (NIGMS)
Type
Research Project (R01)
Project #
5R01GM052798-02
Application #
2378297
Study Section
Surgery and Bioengineering Study Section (SB)
Project Start
1996-03-01
Project End
1999-02-28
Budget Start
1997-03-01
Budget End
1998-02-28
Support Year
2
Fiscal Year
1997
Total Cost
Indirect Cost
Name
Vanderbilt University Medical Center
Department
Biomedical Engineering
Type
Schools of Engineering
DUNS #
004413456
City
Nashville
State
TN
Country
United States
Zip Code
37212
Muratore, Diane M; Russ, Jeannette Herring; Dawant, Benoit M et al. (2002) Three-dimensional image registration of phantom vertebrae for image-guided surgery: a preliminary study. Comput Aided Surg 7:342-52
Stefansic, James D; Bass, W Andrew; Hartmann, Steven L et al. (2002) Design and implementation of a PC-based image-guided surgical system. Comput Methods Programs Biomed 69:211-24
Muratore, D M; Galloway, R L (2001) Beam calibration without a phantom for creating a 3-D freehand ultrasound system. Ultrasound Med Biol 27:1557-66
Stefansic, J D; Herline, A J; Shyr, Y et al. (2000) Registration of physical space to laparoscopic image space for use in minimally invasive hepatic surgery. IEEE Trans Med Imaging 19:1012-23
Herline, A J; Stefansic, J D; Debelak, J P et al. (1999) Image-guided surgery: preliminary feasibility studies of frameless stereotactic liver surgery. Arch Surg 134:644-9;discussion 649-50