Atomic spectrometric methods of analysis are the most commonly used techniques for determining the elemental composition of samples in biomedicine, biochemistry, pharmaceutical science, forensic studies, and in other fields. Unfortunately, existing methods of atomic analysis fall short of meeting the modern needs of these fields in a number of important respects. Prominent among these shortcomings are inadequate sensitivity, speed, and elemental coverage. Also, for many applications the required sample size is excessive, precision is inadequate, and accuracy is dependent on the overall composition of a sample or on the ability of an analyst to match samples and standards closely. In this proposal, a plan of investigation is outlined to continue studies that were begun under NIH sponsorship. In these investigations, a new kind of atomic spectrometric instrument is to be designed, constructed, and tested on real samples. Arguments are first put forward to show that the best source for atomic spectrometry is a tandem one that is assembled from two otherwise independent devices. A first source is assigned the function of accepting a sample of the substance to be analyzed and decomposing it as quantitatively as possible into its constituent atoms. These atoms are then directed into a second source, chosen for its ability to ionize these atoms for subsequent analysis by mass spectrometry. Because each of the two sources is given a specific task, it can be selected for its ability to perform that task; furthermore, its operating conditions can be optimized for that purpose. The result is higher sensitivity, reduced background and sample-dependent errors, and better precision. The time-of- flight mass spectrometer (TOFMS) into which the atomic ions are to be sent is also unusual. Unlike conventional mass spectrometers used for atomic analysis, the TOFMS can produce a complete atomic mass spectrum in as little as 50 microseconds, so it is well suited for analyzing transient or tiny samples. Also, because all the ions measured by the TOFMS are extracted from the tandem source at a single instant in time, that ion population represents a """"""""snapshot"""""""" of the ions in the source. Consequently, ion signals can be ratioed or normalized to improve precision further. Lastly, the new system is expected to be especially powerful when employed with laser ablation for microsampling. Even a single laser shot is projected to yield high-sensitivity elemental analyses or isotope ratios, enabling spatial resolution to be achieved in biological samples and microliter-volume sample solutions to be analyzed rapidly.

Agency
National Institute of Health (NIH)
Institute
National Institute of General Medical Sciences (NIGMS)
Type
Research Project (R01)
Project #
5R01GM053560-03
Application #
2655004
Study Section
Metallobiochemistry Study Section (BMT)
Project Start
1996-02-01
Project End
2000-01-31
Budget Start
1998-02-01
Budget End
2000-01-31
Support Year
3
Fiscal Year
1998
Total Cost
Indirect Cost
Name
Indiana University Bloomington
Department
Chemistry
Type
Schools of Arts and Sciences
DUNS #
006046700
City
Bloomington
State
IN
Country
United States
Zip Code
47401
Mahoney, P P; Ray, S J; Li, G et al. (1999) Preliminary investigation of electrothermal vaporization sample introduction for inductively coupled plasma time-of-flight mass spectrometry. Anal Chem 71:1378-83
Potyrailo, R A; Ruddy, V P; Hieftje, G M (1999) Use of analyte-modulated modal power distribution in multimode optical fibers for simultaneous single-wavelength evanescent-wave refractometry and spectrometry. Anal Chem 71:4956-64
Potyrailo, R A; Hieftje, G M (1998) Optical time-of-flight chemical detection: absorption-modulated fluorescence for spatially resolved analyte mapping in a bidirectional distributed fiber-optic sensor. Anal Chem 70:3407-12
Potyrailo, R A; Hobbs, S E; Hieftje, G M (1998) Near-ultraviolet evanescent-wave absorption sensor based on a multimode optical fiber. Anal Chem 70:1639-45
Pack, B W; Broekaert, J A; Guzowski, J P et al. (1998) Determination of halogenated hydrocarbons by helium microwave plasma torch time-of-flight mass spectrometry coupled to gas chromatography. Anal Chem 70:3957-63
Potyrailo, R A; Hieftje, G M (1998) Optical time-of-flight chemical detection: spatially resolved analyte mapping with extended-length continuous chemically modified optical fibers. Anal Chem 70:1453-61
Potyrailo, R A; Conrad, R C; Ellington, A D et al. (1998) Adapting selected nucleic acid ligands (aptamers) to biosensors. Anal Chem 70:3419-25
Burden, D L; Hieftje, G M (1998) Cerenkov radiation as a UV and visible light source for time-resolved fluorescence. Anal Chem 70:3426-33
Burden, D L; Hobbs, S E; Hieftje, G M (1997) Fluorescence lifetime measurement via a radionuclide-scintillation light source and analog cross correlation. Anal Chem 69:1936-41
Burgoyne, T W; Hieftje, G M; Hites, R A (1997) Space charge evaluation in a plasma-source mass spectrograph. Anal Chem 69:485-9

Showing the most recent 10 out of 11 publications