Idiopathic Respiratory Distress Syndrome (IRDS) remains the major cause of neonatal death in the United States. Many biochemical assay techniques have been developed using amniotic fluid collected from the gravid uterus to indicate whether RDS would develop if delivery occurred immediately after measurement. Several of these biochemical assay techniques have excellent sensitivity and specificity for determining the occurrence of RDS postpartum, but their value for prediction of future dates of maturation or potential to respond to glucocorticoid treatment is quite limited. In addition, amniocentesis, central to all the assay techniques, is an invasive procedure of moderate risk. We propose to examine the use of noninvasive diagnostic ultrasound as an in utero, predictive test of the occurrence of RDS following delivery. Preliminary work on fetal sheep under ideal experimental conditions indicates a strong correlation between quantitative and visual analysis of backscattered ultrasound and the fetal lung's morphological and functional maturity. To demonstrate the applicability of the technique in the real world of the clinic we will modify the methods of the preliminary studies. We will acquire B-mode echograms both on multiformat films for visual analysis and in video format for quantitative analysis of the ratio of lung to liver mean backscattered amplitude. In addition, backscattered radio frequency (rf) ultrasound will be acquired in digital format. Computer processing of the digital data will yield quantitative estimations of fetal organ attenuation and backscatterer size distribution that are insensitive to overlying tissues or scanner TGC settings. Ultrasonic fetal lung measures from both visual and quantitative analysis will be correlated to morphological and functional lung maturity in neonates.

Agency
National Institute of Health (NIH)
Institute
Eunice Kennedy Shriver National Institute of Child Health & Human Development (NICHD)
Type
Research Project (R01)
Project #
5R01HD017243-03
Application #
3314252
Study Section
Diagnostic Radiology Study Section (RNM)
Project Start
1983-04-01
Project End
1986-03-31
Budget Start
1985-04-01
Budget End
1986-03-31
Support Year
3
Fiscal Year
1985
Total Cost
Indirect Cost
Name
University of Michigan Ann Arbor
Department
Type
Schools of Medicine
DUNS #
791277940
City
Ann Arbor
State
MI
Country
United States
Zip Code
48109
Carson, P L; Chiang, E H; Rubin, J M et al. (1991) Pre- to postnatal reduction in ultrasound attenuation coefficient of the liver. Invest Radiol 26:8-12
Adler, R S; Rubin, J M; Bland, P H et al. (1990) Quantitative tissue motion analysis of digitized M-mode images: gestational differences of fetal lung. Ultrasound Med Biol 16:561-9
Carson, P L; Meyer, C R; Chiang, E H et al. (1990) Ultrasound attenuation coefficient in the fetal liver as a function of gestational age. Ultrasound Med Biol 16:399-407
Carson, P L; Rubin, J M; Chiang, E H (1989) Fetal depth and ultrasound path lengths through overlying tissues. Ultrasound Med Biol 15:629-39
Adler, R; Rubin, J M; Bland, P et al. (1989) Characterization of transmitted motion in fetal lung: quantitative analysis. Med Phys 16:333-7
Carson, P L; Rubin, J M; Chiang, E H (1989) Constant soft tissue distance model in pregnancy. Ultrasound Med Biol 15 Suppl 1:27-9
Rubin, J M; Carson, P L; Meyer, C R (1988) Anisotropic ultrasonic backscatter from the renal cortex. Ultrasound Med Biol 14:507-11
Koral, K F; Dupuy, M E; Meyer, C R (1985) Fast envelope detection for thinned display of finely digitized ultrasound scans. IEEE Trans Biomed Eng 32:637-8