In many instances, for example vascular prosthesis, it is the long- term performance of polymeric biomaterials that will determine their clinical usefulness. Advances in the development of improved biomaterials and in the understanding of the mechanisms of arti- ficial surface-induced thrombogenesis must include the assessment of those factors which influence long-term biocompatibility. We propose to use a chronic canine ex vivo shunt technique developed in our laboratory to investigate the influence of polymeric material surface and bulk properties on long-term blood compatibility. Data obtained in the chronic model, will be correlated with that previously obtained for similar materials used in our acute canine ex vivo experiments. As an adjunct to thrombogenicity (platelet activation, platelet deposition etc.) as a description of blood compatibility, we will use the chronic model in studies where patency/failure is the endpoint determinant of biocompatibility. Various flow rates and durations of exposure to blood contact will be used to test material performance in conditions which are possibly more clinically relevant. Chronic ex vivo experiments will provide information on the desorption and exchange of radiolabeled plasma proteins on polymer surfaces over periods in excess of the two hour limit imposed by the acute model. The role of passivating proteins (e.g. albumin and transferrin) in long-term blood exposure will be explored. The effect of endothelial cell seeding on the long-term biocompatibility of polymeric materials will be evaluated in terms of thromboresistance and patency/failure rates in the chronic ex vivo model. These studies will be correlated with in vitro studies of polymer surface-protein-endothelial cell interactions. The biodegradation of polymer surfaces that may occur during long-term blood contact, will be evaluated by post implant bulk and surface characterization techniques such as Gel permeation chromatography, dynamic mechanical testing. Fourier Transform Infrared Spectroscopy with attenuated total Reflectance (FTIRATR), scanning electron microscopy, and x-ray photoelectron spectroscopy. In vitro studies using single and multi-component enzyme mixtures and lipid/enzyme mixtures will attempt to elucidate the pathways involved in the biodegradation of medical grade polymers and modified polyurethanes. These studies will lead to a better understanding of the mechanisms involved in artificial surface-induced thrombogenesis and will aid in the design of biocompatible polymeric materials.

Agency
National Institute of Health (NIH)
Institute
National Heart, Lung, and Blood Institute (NHLBI)
Type
Research Project (R01)
Project #
2R01HL024046-09
Application #
3337475
Study Section
Surgery and Bioengineering Study Section (SB)
Project Start
1979-05-01
Project End
1993-06-30
Budget Start
1988-07-01
Budget End
1989-06-30
Support Year
9
Fiscal Year
1988
Total Cost
Indirect Cost
Name
University of Wisconsin Madison
Department
Type
DUNS #
161202122
City
Madison
State
WI
Country
United States
Zip Code
53715
Silver, J H; Lin, J C; Lim, F et al. (1999) Surface properties and hemocompatibility of alkyl-siloxane monolayers supported on silicone rubber: effect of alkyl chain length and ionic functionality. Biomaterials 20:1533-43
Lim, F; Cooper, S L (1995) Effect of sulphonate incorporation on in vitro leucocyte adhesion to polyurethanes. Biomaterials 16:457-66
Silver, J H; Hergenrother, R W; Lin, J C et al. (1995) Surface and blood-contacting properties of alkylsiloxane monolayers supported on silicone rubber. J Biomed Mater Res 29:535-48
Silver, J H; Myers, C W; Lim, F et al. (1994) Effect of polyol molecular weight on the physical properties and haemocompatibility of polyurethanes containing polyethylene oxide macroglycols. Biomaterials 15:695-704
Hergenrother, R W; Yu, X H; Cooper, S L (1994) Blood-contacting properties of polydimethylsiloxane polyurea-urethanes. Biomaterials 15:635-40
Lim, F; Yang, C Z; Cooper, S L (1994) Synthesis, characterization and ex vivo evaluation of polydimethylsiloxane polyurea-urethanes. Biomaterials 15:408-16
Lin, H B; Sun, W; Mosher, D F et al. (1994) Synthesis, surface, and cell-adhesion properties of polyurethanes containing covalently grafted RGD-peptides. J Biomed Mater Res 28:329-42
Lim, F; Yu, X H; Cooper, S L (1993) Effects of oligoethylene oxide monoalkyl(aryl) alcohol ether grafting on the surface properties and blood compatibility of a polyurethane. Biomaterials 14:537-45
Silver, J H; Marchant, J W; Cooper, S L (1993) Effect of polyol type on the physical properties and thrombogenicity of sulfonate-containing polyurethanes. J Biomed Mater Res 27:1443-57
Silver, J H; Lewis, K B; Ratner, B D et al. (1993) Effect of polyol type on the surface structure of sulfonate-containing polyurethanes. J Biomed Mater Res 27:735-45

Showing the most recent 10 out of 51 publications