The research is a continuation of research begun three years ago. The goal was to improve digital subtraction angiographic (DSA) image quality by incorporating classical tomographic imaging principles along with those of DSA. To a large extent, that goal has been realized except in the area of coronary angiography, where progress has been delayed due to the unexpectedly slow delivery of a moving focal spot x-ray tube. Yet progress in that area has been good. All other components of the real-time coronary artery tomography device (""""""""Tomotron"""""""" system) have been fabricated and bench-tested successfully. It is proposed that our previous efforts be continued in four areas whose combined goal is to establish tomographic angiography as a useful and practically implementable clinical tool. First, optimum arteriographic image quality will be achieved by employing 3-D reconstruction algorithms specifically designed for reconstructing dilute vascular beds from limited angle projection data. Second, true 3-D volume reconstruction, free from the limitations that attend limited angle geometry, will be explored by developing a prototype volume CT scanner using a conventional intensifier and colled CCD array as the detector. Third, a unique, simple, real-time caligraphic display system adapted specifically for viewing 3-D vascular anatomy will be developed and tested. Lastly, the Tomotron system will be assembled and tested both on phantoms and animals. Optimization of imaging performance using this system will be a primary goal.

Agency
National Institute of Health (NIH)
Institute
National Heart, Lung, and Blood Institute (NHLBI)
Type
Research Project (R01)
Project #
5R01HL031984-05
Application #
3343164
Study Section
Radiation Study Section (RAD)
Project Start
1984-04-01
Project End
1989-06-30
Budget Start
1988-04-01
Budget End
1989-06-30
Support Year
5
Fiscal Year
1988
Total Cost
Indirect Cost
Name
University of Utah
Department
Type
Schools of Medicine
DUNS #
City
Salt Lake City
State
UT
Country
United States
Zip Code
84112
Ning, R; Kruger, R A (1996) Image intensifier-based computed tomography volume scanner for angiography. Acad Radiol 3:344-50
Plenkovich, D (1989) Electronic scanning-slit fluorography. Acta Radiol Suppl 373:1-48
Plenkovich, D; Kruger, R A; Sorenson, J A (1987) Electronic scanning-slit fluorography: design and performance of a prototype unit. Med Phys 14:49-55
Plenkovich, D; Sorenson, J A; Kruger, R A (1986) Scatter rejection by electronic collimation. Med Phys 13:158-63
deVries, N; Miller, F J; Wojtowycz, M M et al. (1985) Tomographic digital subtraction angiography: initial clinical studies using tomosynthesis. Work in progress. Radiology 157:239-41