Long term objective: validate and provide new quantitative echocardiographic methods for the study of global and regional ventricular disease.
Aim 1 : To develop valid and precise measures of left ventricular volume mass, and endocardial surface area in infarcted and normal formalin-fixed and isolated ejecting hearts, intact animals, and man with a minimum of global geometric assumption. This will be accomplished by means of a spark-gap transducer locating system in concert with a two-dimensional echocardiographic contouring system, both developed in this laboratory. The result will be three-dimensional reconstruction of multiple two-dimensional echocardiographic images. For ventricular mass in intact dogs and patients, comparison will be made against the actual mass of the excised ventricle. Patients will consist of those undergoing cardiac transplantation; the mass of the explanted ventricle will be readily determined after surgery. The ability to obtain volume, mass and surface area in this way should provide numerous applications to the study of disease states resulting in regional deformation or dysfunction - such as coronary artery disease - where the utility of methods which rely on major global geometric assumptions would be limited.
Aim 2 : To extend and validate an existing computer system for automatic tracking of two-dimensional echocardiograms in animals and man. This will be done by a combination of cross-correlation mapping and edge-tracking techniques. Validation in animals will include images obtained in vitro and in vivo followed by clinical validation. Evaluation and validation of the accuracy and speed of automatic contouring will be made in four steps. 1) alignment accuracy and calibration; 2) formalin-fixed dog and pig hearts to provide echocardiograms from which left ventricular cavity and muscle volume can be measured and quantified; 3) studies using isolated supported ejecting dog hearts to compare both manual and automatically contoured echocardiographic data with absolute frame-by-frame volume data determined accurately with a volumetric chamber apparatus, in both infarcted and non-infarcted ventricles; 4) clinical echocardiograms of varying quality will be used to compare manual and automatic contouring techniques. Finally, we will implement the automatic contouring system for use in three-dimensional echocardiographic reconstruction (Aim 1). This system when validated will enable rapid highly consistent analysis of endocardial and epicardial contours, and allow automated acquisition of data necessary for analysis of regional wall motion, thickening, volume, and endocardial surface area.

Agency
National Institute of Health (NIH)
Institute
National Heart, Lung, and Blood Institute (NHLBI)
Type
Research Project (R01)
Project #
1R01HL033385-01A1
Application #
3345242
Study Section
Cardiovascular Study Section (CVA)
Project Start
1985-09-30
Project End
1988-09-29
Budget Start
1985-09-30
Budget End
1986-09-29
Support Year
1
Fiscal Year
1985
Total Cost
Indirect Cost
Name
Johns Hopkins University
Department
Type
Schools of Medicine
DUNS #
045911138
City
Baltimore
State
MD
Country
United States
Zip Code
21218
Rogers Jr, W J; Shapiro, E P; Weiss, J L et al. (1991) Quantification of and correction for left ventricular systolic long-axis shortening by magnetic resonance tissue tagging and slice isolation. Circulation 84:721-31
Buchalter, M B; Weiss, J L; Rogers, W J et al. (1990) Noninvasive quantification of left ventricular rotational deformation in normal humans using magnetic resonance imaging myocardial tagging. Circulation 81:1236-44
Weiss, J L; Shapiro, E P; Buchalter, M B et al. (1990) Magnetic resonance imaging as a noninvasive standard for the quantitative evaluation of left ventricular mass, ischemia, and infarction. Ann N Y Acad Sci 601:95-106
Beyar, R; Shapiro, E P; Graves, W L et al. (1990) Quantification and validation of left ventricular wall thickening by a three-dimensional volume element magnetic resonance imaging approach. Circulation 81:297-307
Weiss, J L (1990) Echocardiography as an aid in understanding the electrocardiographic changes of left ventricular hypertrophy, ischemia, and infarction. Ann N Y Acad Sci 601:61-6
Azhari, H; Sideman, S; Weiss, J L et al. (1990) Three-dimensional mapping of acute ischemic regions using MRI: wall thickening versus motion analysis. Am J Physiol 259:H1492-503
Grill, H P; Brinker, J A; Taube, J C et al. (1990) Contrast echocardiographic mapping of collateralized myocardium in humans before and after coronary angioplasty. J Am Coll Cardiol 16:1594-600
Marino, P N; Kass, D A; Becker, L C et al. (1989) Influence of site of regional ischemia on nonischemic thickening in anesthetized dogs. Am J Physiol 256:H1417-25
Humphrey, L S; Topol, E J; Rosenfeld, G I et al. (1988) Immediate enhancement of left ventricular relaxation by coronary artery bypass grafting: intraoperative assessment. Circulation 77:886-96