The proposal outlines the investigation of the magnetic resonance (MR) examination parameters that can be used to rapidly provide high quality angiographic images and quantitative flow data of intra- and extra-cranial blood vessels in conjunction with conventional brain imaging. These imaging techniques will then be tested in a clinical setting to verify more physiologic accuracy using intraarterial angiography and doppler ultrasound as objective measures of accuracy. The experiments will address time-of-flight MR angiography with respect to: 1) Optimization of vessel signal and contrast by pulse sequence design to maximize flow related enhancement (orientation, repetition time (TR), flip angle) and minimize motion induced phase dispersion (voxel size, refoccusing techniques and echo-time (TE) reduction). 2) Improvements in spatial resolution in the presence of data sampling and field of view constraints via new reconstruction techniques and optimized sequences. 3) Artifact reduction and isolation of vascular territories by implementing saturation pulses. 4) Physiological monitoring/flow quantification via phase analysis utilizing Doppler ultrasound as a measure of accuracy in patients. 5) Verification of morphologic accuracy and anatomic fidelity using conventional intraarterial angiography as a standard of comparison for both individual 2D and 3D projections. 6) Clinical trials in circumstances of cerebrovascular disease not readily amenable to presently available diagnostic techniques. While parenchymal MR changes are commonly used in clinical practice, application of flow effects remain limited. Research in this area will provide a better, practical understanding of MR's potential as a routine vascular imaging modality. The ultimate goal is the development of a reliable, cost-effective and non-invasive clinical exam providing accurate vascular images and flow data in conjunction with routine MR with minimal or no increase in patient exam time (and thus expense).

Agency
National Institute of Health (NIH)
Institute
National Heart, Lung, and Blood Institute (NHLBI)
Type
Research Project (R01)
Project #
1R01HL043812-01A1
Application #
3362570
Study Section
Diagnostic Radiology Study Section (RNM)
Project Start
1990-08-01
Project End
1993-07-31
Budget Start
1990-08-01
Budget End
1991-07-31
Support Year
1
Fiscal Year
1990
Total Cost
Indirect Cost
Name
Cleveland Clinic Lerner
Department
Type
DUNS #
017730458
City
Cleveland
State
OH
Country
United States
Zip Code
44195
Obuchowski, N A (2001) Can electronic medical images replace hard-copy film? Defining and testing the equivalence of diagnostic tests. Stat Med 20:2845-63
Obuchowski, N A; Lieber, M L; Magdenic, M et al. (1999) Small but quantifiable patient preference for MRA versus catheter angiography. Stroke 30:2247-8
Perl 2nd, J; Tkach, J A; Porras-Jimenez, M et al. (1999) Hemorrhage detected using MR imaging in the setting of acute stroke: an in vivo model. AJNR Am J Neuroradiol 20:1863-70
Obuchowski, N A (1997) Nonparametric analysis of clustered ROC curve data. Biometrics 53:567-78
Obuchowski, N A; Modic, M T; Magdinec, M et al. (1997) Assessment of the efficacy of noninvasive screening for patients with asymptomatic neck bruits. Stroke 28:1330-9
Ding, X; Tkach, J; Ruggieri, P et al. (1997) Improvement of spiral MRI with the measured k-space trajectory. J Magn Reson Imaging 7:938-40
Tkach, J A; Ding, X; Ruggieri, P M et al. (1997) Segmented three-dimensional echo-planar flow imaging of the cervical carotid arteries. AJNR Am J Neuroradiol 18:1339-47
Ruggieri, P M; Poulos, N; Masaryk, T J et al. (1994) Occult intracranial aneurysms in polycystic kidney disease: screening with MR angiography. Radiology 191:33-9
Ding, X; Tkach, J A; Ruggieri, P R et al. (1994) Sequential three-dimensional time-of-flight MR angiography of the carotid arteries: value of variable excitation and postprocessing in reducing venetian blind artifact. AJR Am J Roentgenol 163:683-8
Tkach, J A; Ruggieri, P M; Dillinger, J J et al. (1993) Three-dimensional time-of-flight MR angiography with a specialized gradient head coil. J Magn Reson Imaging 3:365-75

Showing the most recent 10 out of 16 publications