This is an application for competitive renewal of an R01 whose focus is the detection of myocardial viability and infarction by contrast-enhanced MRI. The past four years of funding have supported a series of basic science studies focused primarily on the relationship of """"""""delayed hyperenhancement"""""""" to myocardial necrosis and scar. These studies formed the basis for clinical studies of """"""""delayed enhancement"""""""" which demonstrated the technique can be used to predict recovery of contractile function following revascularization and that it can be used to detect subendocardial human infarcts which are routinely missed by existing diagnostic techniques. On the basis of our work and that of other groups, the """"""""delayed enhancement"""""""" technique is now being used at growing number of medical institutions and was recently recognized in a survey by the Society of Cardiovascular Magnetic Resonance as """"""""the most important clinical application of cardiovascular magnetic resonance"""""""" (see Figure 1). Despite these successes, however, recent data also demonstrate that the """"""""delayed enhancement"""""""" technique can underestimate or overestimate the true spatial extent of myocardial viability and infarction depending on how the imaging protocol is performed (see Figure 2). This issue limits widespread use of the technique for clinical diagnosis, limits its use as an end-point for multicenter clinical trials, and limits its use as a tool for the study of new physiology.
In Specific Aim 1 we propose to establish how in vivo measurements of the transmural extent of infarction and total infarct size are affected by the imaging protocol and, by comparison to the """"""""gold standard"""""""" of histologic examination, to define guidelines which can be used to assure accurate, reproducible measurements at multiple institutions using the """"""""traditional"""""""" segmented IR-FLASH pulse sequence.
In Specific Aim 2 we propose to develop entirely new MRI pulse sequences which, as demonstrated in our """"""""Preliminary Studies"""""""", address clinically-relevant limitations of segmented IR-FLASH. We then propose (Aim 3) to test the hypothesis that the standardized techniques established by Aims 1 and 2 can be used to better define myocardial infarct size than any existing technique. If this hypothesis proves correct, the use of MRI """"""""delayed enhancement"""""""" as the end-point for clinical trials will significantly reduce the number of patients needed to evaluate new therapies. The overall goal of these studies is to establish the foundation for widespread use of the """"""""delayed enhancement"""""""" technique for both routine clinical diagnosis and multi-center clinical investigation.

Agency
National Institute of Health (NIH)
Institute
National Heart, Lung, and Blood Institute (NHLBI)
Type
Research Project (R01)
Project #
2R01HL063268-06A2
Application #
6873234
Study Section
Medical Imaging Study Section (MEDI)
Program Officer
Liang, Isabella Y
Project Start
1999-07-01
Project End
2008-11-30
Budget Start
2004-12-15
Budget End
2005-11-30
Support Year
6
Fiscal Year
2005
Total Cost
$346,500
Indirect Cost
Name
Duke University
Department
Internal Medicine/Medicine
Type
Schools of Medicine
DUNS #
044387793
City
Durham
State
NC
Country
United States
Zip Code
27705
Mendoza, Dorinna D; Kochar, Minisha; Devereux, Richard B et al. (2011) Impact of image analysis methodology on diagnostic and surgical classification of patients with thoracic aortic aneurysms. Ann Thorac Surg 92:904-12
Weinsaft, Jonathan W; Kim, Han W; Crowley, Anna Lisa et al. (2011) LV thrombus detection by routine echocardiography: insights into performance characteristics using delayed enhancement CMR. JACC Cardiovasc Imaging 4:702-12
Patel, Manesh R; Cawley, Peter J; Heitner, John F et al. (2009) Detection of myocardial damage in patients with sarcoidosis. Circulation 120:1969-77
Kim, Han W; Klem, Igor; Shah, Dipan J et al. (2009) Unrecognized non-Q-wave myocardial infarction: prevalence and prognostic significance in patients with suspected coronary disease. PLoS Med 6:e1000057
Thomson, Louise E J; Crowley, Anna Lisa; Heitner, John F et al. (2008) Direct en face imaging of secundum atrial septal defects by velocity-encoded cardiovascular magnetic resonance in patients evaluated for possible transcatheter closure. Circ Cardiovasc Imaging 1:31-40
Klem, Igor; Greulich, Simon; Heitner, John F et al. (2008) Value of cardiovascular magnetic resonance stress perfusion testing for the detection of coronary artery disease in women. JACC Cardiovasc Imaging 1:436-45
Weinsaft, Jonathan W; Kim, Han W; Shah, Dipan J et al. (2008) Detection of left ventricular thrombus by delayed-enhancement cardiovascular magnetic resonance prevalence and markers in patients with systolic dysfunction. J Am Coll Cardiol 52:148-57
Sievers, Burkhard; Elliott, Michael D; Hurwitz, Lynne M et al. (2007) Rapid detection of myocardial infarction by subsecond, free-breathing delayed contrast-enhancement cardiovascular magnetic resonance. Circulation 115:236-44
Wagner, Anja; Mahrholdt, Heiko; Thomson, Louise et al. (2006) Effects of time, dose, and inversion time for acute myocardial infarct size measurements based on magnetic resonance imaging-delayed contrast enhancement. J Am Coll Cardiol 47:2027-33
Klem, Igor; Heitner, John F; Shah, Dipan J et al. (2006) Improved detection of coronary artery disease by stress perfusion cardiovascular magnetic resonance with the use of delayed enhancement infarction imaging. J Am Coll Cardiol 47:1630-8

Showing the most recent 10 out of 33 publications