Defibrillation is the only therapy available for victims of sudden cardiac death. However, high energy deflbrillation shocks may result in myocardial dysfunction and damage. A rising number of ICD malfunctions in recent years is associated with the failure of high-voltage components. We propose to develop a novel approach to defibrillation, which may result in a 20-fold reduction in delivered energy. Presently, implantable cardioverter-defibrillators terminate ventricular tachycardia (VT) by low-energy anti-tachycardia pacing (ATP). A high energy defibrillation shock is applied only when ATP fails. We hypothesize that ATP fails in cases of anatomically defined reentrant VT pinned to scars, areas of fibroses, because scars stabilize the reentry. We propose to convert anchored reentry into a functionally defined (unpinned) arrhythmia by a properly timed low-energy unpinning shock. We further hypothesize that following unpinning, VT can be terminated by anti-repinning pacing (ARP) which will prevent its degeneration into ventricular fibrillation (VF). We will use state-of-the art panoramic imaging with voltage-sensitive dye, multielectrode mapping, and bidomain modeling to pursue the following Specific Aims in rabbit and canine models of infarction: 1. To investigate the role of small scale endocardial structural heterogeneity in anchoring reentrant arrhythmias and their unpinning in the rabbit isolated right ventricle. Based on the elucidated biophysical mechanisms, to optimize unpinning and VT termination by an ARP protocol;2. To investigate the role of global structural and functional heterogeneity in anchoring reentrant arrhythmias and their unpinning in isolated preparations and intact rabbit hearts with myocardial infarction. Based on the elucidated biophysical mechanisms, to optimize sensing, unpinning, and VT termination by ARP protocol;3. Using open-chest epicardial mapping, to demonstrate the feasibility of unpinning and ARP termination of VT in canines with 4-day myocardial infarction. To optimize sensing, unpinning and ARP protocols. This research will lead to the development of a novel defibrillation strategy, which will reduce the number of applications of high-energy shocks, replacing them with low-energy unpinning shocks and ARP. This energy reduction will improve the life time and reliability of implantable devices and will reduce the side-effects of defibrillation. It is also likely to reduce the number of ICD malfunctions and reimplantations.

Agency
National Institute of Health (NIH)
Institute
National Heart, Lung, and Blood Institute (NHLBI)
Type
Research Project (R01)
Project #
5R01HL067322-07
Application #
7617126
Study Section
Special Emphasis Panel (ZRG1-CVS-A (02))
Program Officer
Lathrop, David A
Project Start
2001-08-06
Project End
2011-04-30
Budget Start
2009-05-01
Budget End
2010-04-30
Support Year
7
Fiscal Year
2009
Total Cost
$476,796
Indirect Cost
Name
Washington University
Department
Biomedical Engineering
Type
Schools of Engineering
DUNS #
068552207
City
Saint Louis
State
MO
Country
United States
Zip Code
63130
Janardhan, Ajit H; Gutbrod, Sarah R; Li, Wenwen et al. (2014) Multistage electrotherapy delivered through chronically-implanted leads terminates atrial fibrillation with lower energy than a single biphasic shock. J Am Coll Cardiol 63:40-8
Glukhov, Alexey V; Fedorov, Vadim V; Kalish, Paul W et al. (2012) Conduction remodeling in human end-stage nonischemic left ventricular cardiomyopathy. Circulation 125:1835-47
Lou, Qing; Li, Wenwen; Efimov, Igor R (2012) The role of dynamic instability and wavelength in arrhythmia maintenance as revealed by panoramic imaging with blebbistatin vs. 2,3-butanedione monoxime. Am J Physiol Heart Circ Physiol 302:H262-9
Laughner, Jacob I; Zhang, Song; Li, Hao et al. (2012) Mapping cardiac surface mechanics with structured light imaging. Am J Physiol Heart Circ Physiol 303:H712-20
Janardhan, Ajit H; Li, Wenwen; Fedorov, Vadim V et al. (2012) A novel low-energy electrotherapy that terminates ventricular tachycardia with lower energy than a biphasic shock when antitachycardia pacing fails. J Am Coll Cardiol 60:2393-8
Laughner, Jacob I; Ng, Fu Siong; Sulkin, Matthew S et al. (2012) Processing and analysis of cardiac optical mapping data obtained with potentiometric dyes. Am J Physiol Heart Circ Physiol 303:H753-65
Rantner, Lukas J; Arevalo, Hermenegild J; Constantino, Jason L et al. (2012) Three-dimensional mechanisms of increased vulnerability to electric shocks in myocardial infarction: altered virtual electrode polarizations and conduction delay in the peri-infarct zone. J Physiol 590:4537-51
Laughner, Jacob I; Sulkin, Matthew S; Wu, Ziqi et al. (2012) Three potential mechanisms for failure of high intensity focused ultrasound ablation in cardiac tissue. Circ Arrhythm Electrophysiol 5:409-16
Bordas, R; Gillow, K; Lou, Q et al. (2011) Rabbit-specific ventricular model of cardiac electrophysiological function including specialized conduction system. Prog Biophys Mol Biol 107:90-100
Lou, Qing; Fedorov, Vadim V; Glukhov, Alexey V et al. (2011) Transmural heterogeneity and remodeling of ventricular excitation-contraction coupling in human heart failure. Circulation 123:1881-90

Showing the most recent 10 out of 94 publications