Cardiovascular disease is the leading cause of death in both men and women in the United States. Over 16 million Americans have coronary heart disease (CHD), causing about 0.5 million deaths each year. The most common CHD is coronary artery disease which is mainly caused by atherosclerosis. Clinical evidence in recent years shows that noncalcified plaques (NCPs) are more vulnerable to rupture than calcified plaques. Plaque rupture and the thrombosis that follows is the main cause of acute myocardial infarction. Multidetector coronary CT angiography (cCTA) has the potential to help clinicians in early detection and in quantification of NCPs. cCTA may thus be useful for CHD detection, risk stratification, monitoring, and evaluation of the effectiveness of risk reduction treatment. However, many of these potential applications have not been utilized clinically. The goal of this project is to develop a computer-aided detection (CADe) system to serve as a second reader for assisting clinicians in detection and quantification of NCPs in cCTA exams.
Our specific aims are to (1) develop machine learning methods for detection of NCPs causing stenosis and/or positive remodeling along coronary arteries, and (2) evaluate the effect of CADe on radiologists'detection of NCPs on cCTA by observer ROC study. To achieve these aims, we will collect a database of cCTA cases for training and testing the CADe system, define the search space by designing 3D multiscale coronary artery response enhancement, segmentation, and dynamic balloon vessel tracking methods, develop a unique vessel- stitching method to automatically identify the best-quality phase for each individual artery segment from all available phases in prospectively or retrospectively gated cCTA exams, develop innovative vessel-sector- profile analysis and vessel lumen analysis to detect NCPs that cause stenosis or positive remodeling, estimate the total NCP volume, and explore calibration method to quantify plaque density by phantom studies. To demonstrate the usefulness of CADe, a preclinical reader study will be conducted to compare radiologists'detection accuracy of NCPs with and without CADe. The major innovations of this project include (1) being the first CADe system to automatically detect non-calcified plaques including those cause positive remodeling or stenosis in cCTA, (2) development of new machine learning techniques including the vessel-stitching method, vessel-sector-profile analysis, multiscale enhancement response, and dynamic balloon tracking specifically suited for coronary arterial trees, and (3) conducting the first ROC study to evaluate the effect of CADe on radiologists'detection of NCPs.

Public Health Relevance

Cardiovascular disease is the leading cause of death in both men and women in the United States. If the proposed CADe system is successfully developed, it will (1) provide an accurate, efficient, and consistent tool to assist clinicians in detecting and quantifying non-calcified plaques (NCP) including those causing positive remodeling and/or stenosis for an individual patient, (2) help clinicians estimate the total NCP burden and study its significance, in analogy to that of the total calcium score, which may lead to improved clinical management of the vulnerable plaques, and (3) accelerate studies to develop new treatment options of coronary heart disease by providing a monitoring tool of treatment response. The proposed CADe system can thus serve as a foundation for these broader future applications and improve the efficacy of cCTA. Improved detection and management of NCPs may reduce the risk of myocardial infarctions and will have strong and long-lasting impact on health care.

Agency
National Institute of Health (NIH)
Institute
National Heart, Lung, and Blood Institute (NHLBI)
Type
Research Project (R01)
Project #
5R01HL106545-03
Application #
8392109
Study Section
Biomedical Imaging Technology Study Section (BMIT)
Program Officer
Danthi, Narasimhan
Project Start
2010-12-15
Project End
2014-11-30
Budget Start
2012-12-01
Budget End
2013-11-30
Support Year
3
Fiscal Year
2013
Total Cost
$552,793
Indirect Cost
$190,351
Name
University of Michigan Ann Arbor
Department
Radiation-Diagnostic/Oncology
Type
Schools of Medicine
DUNS #
073133571
City
Ann Arbor
State
MI
Country
United States
Zip Code
48109
Hadjiiski, Lubomir; Liu, Jordan; Chan, Heang-Ping et al. (2016) Best-Quality Vessel Identification Using Vessel Quality Measure in Multiple-Phase Coronary CT Angiography. Comput Math Methods Med 2016:1835297
Zhou, Chuan; Chan, Heang-Ping; Hadjiiski, Lubomir M et al. (2016) Coronary artery analysis: Computer-assisted selection of best-quality segments in multiple-phase coronary CT angiography. Med Phys 43:5268
Wei, Jun; Zhou, Chuan; Chan, Heang-Ping et al. (2014) Computerized detection of noncalcified plaques in coronary CT angiography: evaluation of topological soft gradient prescreening method and luminal analysis. Med Phys 41:081901
Zhou, Chuan; Chan, Heang-Ping; Chughtai, Aamer et al. (2014) Computerized analysis of coronary artery disease: performance evaluation of segmentation and tracking of coronary arteries in CT angiograms. Med Phys 41:081912
Hadjiiski, Lubomir; Zhou, Chuan; Chan, Heang-Ping et al. (2014) Coronary CT angiography (cCTA): automated registration of coronary arterial trees from multiple phases. Phys Med Biol 59:4661-80
Zhou, Chuan; Chan, Heang-Ping; Chughtai, Aamer et al. (2012) Automated coronary artery tree extraction in coronary CT angiography using a multiscale enhancement and dynamic balloon tracking (MSCAR-DBT) method. Comput Med Imaging Graph 36:1-10