The long term objective of this research is to provide a Ventricular Assist Device (VAD) designed specifically for infants, who require mechanical circulatory support of left, right, or both ventricles. The use of VADs in adults has become a viable means of support in end stage heart disease, as a bridge-to-transplant, and more recently as destination therapy. However, the only devices currently available for infants are either limited in support duration (typically 1 month) or carry significant thromboembolic and bleeding risks. The specific objective of this project is to perform pre-clinical testing of the Pen State Infant VAD. The Penn State Infant VAD is a pulsatile pneumatically-actuated pump with a 12-14 ml stroke volume. The device has demonstrated low thrombogenicity in pilot animal studies, in part due to the custom Bjork-Shiley monostrut valves, as used in the Thoratec adult VAD. The monostrut valve does not exhibit the recirculation regions found behind the leaflets in polymer trileaflet valves. We have also developed an innovative approach to cannulae design, which has been a shortcoming in current pediatric VADs, and which is critical to reducing thromboembolic risk, especially in infants and in those with congenital anatomic variability. The primary objective of this project is to perform pre-clinical testing (in vivo and in vitro) of the enn State Infant VAD and new cannulae system, leading to a clinical trial. A secondary objective is to investigate the mechanisms of thrombus formation, thromboembolism in a VAD system, by testing of the Infant VAD over a wider range of pump flow and anticoagulation states than would normally be required for regulatory approval, using multiple measures of coagulation, platelet function, renal function, and explant analyses. This objective represents an opportunity to contribute to the broader field of circulatory support device development and the design of animal testing protocols, especially in regards to anticoagulation approaches.
The specific aims are: 1) to perform pre-clinical testing in animals to assess thrombogenicity of the Infant VAD system utilizing the 15-25 kg lamb model in 60 day chronic studies, 2) to assess the thrombogenic potential of the Infant VAD system in weaning mode, in which the VAD flowrate is reduced, and 3) to demonstrate reliability of 0.80 with 80% confidence for a six-month system design, with testing to demonstrate device reliability by sustained operation for periods at least twice as long as the intended use (i.e. one year).

Public Health Relevance

A Ventricular Assist Device (VAD) is being developed to provide circulatory support in infants who are awaiting heart transplantation or who need time to recover their heart function. The VAD will utilize innovative cannulae designs to provide both left and right heart support with minimal thromboembolic risk. Under this project, the Infant VAD will undergo pre-clinical animal testing and durability testing.

Agency
National Institute of Health (NIH)
Institute
National Heart, Lung, and Blood Institute (NHLBI)
Type
Research Project (R01)
Project #
5R01HL108123-03
Application #
8681498
Study Section
Bioengineering, Technology and Surgical Sciences Study Section (BTSS)
Program Officer
Baldwin, Tim
Project Start
2012-07-02
Project End
2016-06-30
Budget Start
2014-07-01
Budget End
2015-06-30
Support Year
3
Fiscal Year
2014
Total Cost
Indirect Cost
Name
Pennsylvania State University
Department
Surgery
Type
Schools of Medicine
DUNS #
City
Hershey
State
PA
Country
United States
Zip Code
17033
Good, Bryan C; Weiss, William J; Deutsch, Steven et al. (2017) Asynchronous Pumping of a Pulsatile Ventricular Assist Device in a Pediatric Anastomosis Model. World J Pediatr Congenit Heart Surg 8:511-519
Caimi, Alessandro; Sturla, Francesco; Good, Bryan et al. (2017) Toward the Virtual Benchmarking of Pneumatic Ventricular Assist Devices: Application of a Novel Fluid-Structure Interaction-Based Strategy to the Penn State 12 cc Device. J Biomech Eng 139:
Good, Bryan C; Deutsch, Steven; Manning, Keefe B (2016) Continuous and Pulsatile Pediatric Ventricular Assist Device Hemodynamics with a Viscoelastic Blood Model. Cardiovasc Eng Technol 7:23-43
Good, Bryan C; Deutsch, Steven; Manning, Keefe B (2016) Hemodynamics in a Pediatric Ascending Aorta Using a Viscoelastic Pediatric Blood Model. Ann Biomed Eng 44:1019-35
Cooper, Timothy K (2015) Letter to the Editor regarding the article ""Left ventricular assist devices: a kidney's perspective"". Heart Fail Rev 20:751-2