The broad, long term objective of the proposed grant is to develop an integrated multimodal intravascular imaging system that combines intravascular optical coherence tomography (OCT), ultrasound (US), and phase-resolved acoustic radiation force optical coherence elastography (ARF-OCE). The multimodal intravascular imaging system is unique in that it combines the advantages of the high spatial resolution of OCT, the broad imaging depth of US, and the biomechanical contrast of ARF-OCE. Visualizing plaques to help understand the progression of disease and to aid in diagnosis and treatment is highly desirable. Both in vitro and in vivo studies have shown that fatty tissue has a higher strain than fibrous plaques and that vulnerable plaques are in high strain areas surrounded by low strain areas. More recent studies have pointed to the vulnerability and the risk of rupturing of plaques being related to the stress on the fibrous cap, the cap thickness, arterial remodeling, and the composition of the plaques. Therefore, it is important to measure the biomechanical properties of the artery tissue to monitor the atherosclerosis to reduce the rupture proneness of an artery and to correlate with clinical symptoms and inflammation markers. The combined multimodal vascular imaging system will permit cross-sectional visualization of vasculature with high spatial resolution, broad imaging depth, and high biomechanical sensitivity, which is not possible by any of these technologies alone. The integrated OCT/US/ARF-OCE will provide the physician with a powerful tool for imaging, diagnosing, and managing vulnerable plaques. Furthermore, this multi-modal imaging strategy in a single system permits the use of a single disposable guide wire and catheter, thereby reducing costs to hospitals and patients, and improving prognosis by early detection.
The specific aims are: (1) Design and develop an integrated intravascular OCT/US/ARF-OCE imaging probe, (2) Design and develop an integrated intravascular OCT/US/ARF-OCE system, (3) Develop algorithms for image reconstruction and biomechanical property determination, (4) Image cardiovascular plaques in rabbits and porcine animal models using an integrated OCT/US/ARF-OCE system, and (5) Demonstrate clinical applications of the integrated multimodal imaging system in pilot in vivo human subject studies. The proposed research is expected to have significant impact in the earlier detection, prevention, and treatment of cardiovascular diseases. PHS 398

Public Health Relevance

Despite significant advance in medicine, cardiovascular diseases remain the number one killer in America. We propose to develop an integrated multimodal intravascular imaging system that combines high resolution of optical coherence tomography, deep tissue penetration of ultrasound imaging, and biomechanical contrast of optical coherence elastography. The integrated imaging system will permit cross-sectional visualization of vascular artery with high spatial resolution, broad imaging depth, and high biomechanical sensitivity not possible with any of these technologies alone. The proposed research is expected to have significant impact in the earlier detection, prevention, and treatment of cardiovascular diseases. PHS 398

Agency
National Institute of Health (NIH)
Institute
National Heart, Lung, and Blood Institute (NHLBI)
Type
Research Project (R01)
Project #
5R01HL125084-06
Application #
8913262
Study Section
Biomedical Imaging Technology Study Section (BMIT)
Program Officer
Danthi, Narasimhan
Project Start
2014-08-15
Project End
2018-04-30
Budget Start
2015-05-01
Budget End
2016-04-30
Support Year
6
Fiscal Year
2015
Total Cost
$664,990
Indirect Cost
$158,376
Name
University of California Irvine
Department
Biomedical Engineering
Type
Schools of Engineering
DUNS #
046705849
City
Irvine
State
CA
Country
United States
Zip Code
92697
Li, Yan; Chen, Zhongping (2018) Multimodal Intravascular Photoacoustic and Ultrasound Imaging. Biomed Eng Lett 8:193-201
Li, Yan; Sudol, Neha T; Miao, Yusi et al. (2018) 1.7 micron optical coherence tomography for vaginal tissue characterization in vivo. Lasers Surg Med :
Yang, Qiang; Miao, Yusi; Huo, Tiancheng et al. (2018) Deep imaging in highly scattering media by combining reflection matrix measurement with Bessel-like beam based optical coherence tomography. Appl Phys Lett 113:011106
Qu, Yueqiao; He, Youmin; Saidi, Arya et al. (2018) In Vivo Elasticity Mapping of Posterior Ocular Layers Using Acoustic Radiation Force Optical Coherence Elastography. Invest Ophthalmol Vis Sci 59:455-461
Moon, Sucbei; Qu, Yueqiao; Chen, Zhongping (2018) Characterization of spectral-domain OCT with autocorrelation interference response for axial resolution performance. Opt Express 26:7253-7269
Miao, Yusi; Jing, Joseph C; Desai, Vineet et al. (2018) Automated 3D segmentation of methyl isocyanate-exposed rat trachea using an ultra-thin, fully fiber optic optical coherence endoscopic probe. Sci Rep 8:8713
Moon, Sucbei; Chen, Zhongping (2018) Phase-stability optimization of swept-source optical coherence tomography. Biomed Opt Express 9:5280-5295
Yu, Mingyue; Li, Yang; Ma, Teng et al. (2017) Intravascular Ultrasound Imaging With Virtual Source Synthetic Aperture Focusing and Coherence Factor Weighting. IEEE Trans Med Imaging 36:2171-2178
Zhu, Jiang; Zhang, Buyun; Qi, Li et al. (2017) Quantitative angle-insensitive flow measurement using relative standard deviation OCT. Appl Phys Lett 111:181101
Li, Yan; Jing, Joseph; Heidari, Emon et al. (2017) Intravascular Optical Coherence Tomography for Characterization of Atherosclerosis with a 1.7 Micron Swept-Source Laser. Sci Rep 7:14525

Showing the most recent 10 out of 35 publications