The annual incidence of pediatric heart failure due to congenital heart disease (CHD) is 1 to 2 cases per 1000 births. Whereas 10,000 to 14,000 children are hospitalized annually in the United States waiting for a new heart, only 444 transplants were performed in 2016, illustrating the drastic shortage of donor hearts. The only long- term treatment alternative to a heart transplant is the implantation of a ventricular assist device (VAD), a pump that helps the failing heart to pump blood until a new heart is available. However, these VADs are too large to be fully implantable in children under 4 years of age; therefore, these VADs are placed externally near the abdomen, with tubes running through the skin. These tubes can lead to infection, and they prevent the children from leaving the hospital for the duration of pump support, which can exceed 1 year. Additionally, the survival rate of patients weighing less than 5 kg with the currently available VADs is dismal; more than 60% of these children die after VAD implantation, stroke being the most common cause of death. Therefore, there is a need to design a safer, fully implantable pediatric VAD to improve the survival of both infants and young children. This VAD also needs to be adjustable with the child?s growth and development, meaning that it must provide higher blood flow and pressure as the child grows. The objective of this study is to develop the first fully implantable VAD (NeoVAD) for infants and young children, which would help the failing heart until a suitable donor heart is available.
In Aim 1, development of a miniature magnetic levitation system to eliminate mechanical wear and optimize the pump performance is proposed, which will provide a long-term circulatory support. The hemodynamic performance of the NeoVAD in steady-state flow environments at different physiological operating points will be investigated in Aim 2. Finally, in Aim 3, systemic hemocompatibility and hemodynamic performance of the NeoVAD will be evaluated by in vitro and large-animal studies. This pump, after implantation, would allow pediatric heart failure patients to return to a near-normal life outside the hospital. This research will give new insights into designing a pump that can support the failing heart for a wide range of patients, from infants to children weighing up to 20 kg. This wide range of support would eliminate the need to change VADs or undergo multiple heart transplants as the child grows, both of which are risky procedures. Also, this research will include an in-depth study of pump-blood interaction across the patient age range, allowing us to study how blood shear stress is affected by changes in blood flow rate and pressure as the child grows. This study will enable us to design the first safe, fully implantable VAD for young children, which would reduce the risk of stroke, bleeding, and infection and improve their chances of survival. We expect that with the implanted NeoVAD, pediatric CHD patients can live a near-normal life outside the hospital, which would be a significant improvement in their quality of life.

Public Health Relevance

Nearly 10,000 to 14,000 children with congenital heart disease are hospitalized annually in the United States waiting for a new heart, while only a very small percentage of the children can have heart transplantation because of the drastic shortage of the suitable donors. The purpose of this study is to develop the first fully implantable circulatory support device pump (NeoVAD) that is small enough to implant into the chest of infants and small children; this device would help the failing heart until a heart transplant is available. Thus, this device will slow down heart failure progression in the pediatric congenital heart disease patients and enable them to return to a near-normal life.

Agency
National Institute of Health (NIH)
Institute
National Heart, Lung, and Blood Institute (NHLBI)
Type
Research Project (R01)
Project #
1R01HL153538-01
Application #
10029559
Study Section
Bioengineering, Technology and Surgical Sciences Study Section (BTSS)
Program Officer
Burns, Kristin
Project Start
2020-08-01
Project End
2024-06-30
Budget Start
2020-08-01
Budget End
2021-06-30
Support Year
1
Fiscal Year
2020
Total Cost
Indirect Cost
Name
Texas Heart Institute
Department
Type
DUNS #
086987831
City
Houston
State
TX
Country
United States
Zip Code
77225