Maintaining adequate oxygenation for neonates who need ventilatory support is essential for optimal health outcomes in this vulnerable group. To avoid oxygen toxicity, neonates are aggressively weaned from the ventilator. Neonates on ventilators are more sensitive to stimuli and frequently develop desaturation episodes, apnea, and bradycardia. They are at greater risk of hypoxemia, in part because of their high fetal hemoglobin level. Accurate and continuous oxygen saturation (SO2) status is crucial.
The aims of this study are: 1. to examine the effects of using fiberoptic umbilical catheters to monitor arterial and venous SO2 (SaO2 and SvO2) on ventilatory weaning and oxygenation complications including hyperoxemia and hypoxemia; 2. to validate bedside monitoring of SaO2, SvO2, and pulse oximetry (SpO2) by examining: a.) the effect of fetal hemoglobin on the accuracy of SO2 monitoring, using a gold standard co-oximeter, and b.) the association between SO2 and oxygen tension values in neonates; 3. to examine the effects of ventilatory weaning on SO2 readings and vagal tone as measured by ECG R-R intervals. Neonates who need an umbilical arterial catheter (UAC) and an umbilical venous catheter (UVC) will be randomly assigned to the fiberoptic group (n=120) or the control group (n=120) based on five prenatal and five birth characteristics using the minimization method. Ventilatory support and oxygenation complications will be followed. The fiberoptic group will be monitored on SaO2 and SvO2 through fiberoptic catheters, in addition to SpO2. These measurements will be validated at 4-hour intervals against a co-oximeter, taking into account the effects of fetal hemoglobin on SO2. A bedside computer will be used to continuously record SaO2, SvO2, SpO2, and ECG R-R intervals. Using a computerized coding system, a data collector along with a video camera will continuously record bedside care events including each ventilatory weaning attempt. This study will determine whether SaO2 and SvO2 monitoring will improve the success of ventilatory weaning and reduce oxygenation complications. In addition, the study will examine oxygen utilization and hemodynamic function when neonates adapt to extrauterine life during ventilatory support.

Agency
National Institute of Health (NIH)
Institute
National Institute of Nursing Research (NINR)
Type
Research Project (R01)
Project #
7R01NR004447-02
Application #
2801600
Study Section
Nursing Research Study Section (NURS)
Program Officer
Sigmon, Hilary D
Project Start
1998-04-01
Project End
2002-03-31
Budget Start
1998-07-15
Budget End
1999-03-31
Support Year
2
Fiscal Year
1998
Total Cost
Indirect Cost
Name
Oregon Health and Science University
Department
Other Health Professions
Type
Schools of Nursing
DUNS #
009584210
City
Portland
State
OR
Country
United States
Zip Code
97239
Shiao, Shyang-Yun Pamela K; Ahn, Chul W; Akazawa, Kouhei (2007) Second-order interactions with the treatment groups in controlled clinical trials. Comput Methods Programs Biomed 86:10-6
Shiao, Shyang-Yun Pamela K; Ou, Ching-Nan (2007) Validation of oxygen saturation monitoring in neonates. Am J Crit Care 16:168-78
Shiao, Shyang-Yun Pamela K; Ou, Ching-Nan (2006) Accurate measurements of fetal hemoglobin for neonates with different gestational ages. Hemoglobin 30:419-35
Shiao, Shyang-Yun Pamela K; Ou, Ching-Nan; Pierantoni, Hector (2006) The measurement of accurate fetal hemoglobin and related oxygen saturation by the hemoximeter. Clin Chim Acta 374:75-80
Shiao, Shyang-Yun Pamela K (2005) Effects of fetal hemoglobin on accurate measurements of oxygen saturation in neonates. J Perinat Neonatal Nurs 19:348-61
Shiao, Shyang-Yun Pamela K; Andrews, Claire M; Helmreich, Rebecca Jo (2005) Maternal race/ethnicity and predictors of pregnancy and infant outcomes. Biol Res Nurs 7:55-66
Shiao, Shyang-Un Pamela (2002) Functional versus fractional oxygen saturation readings: bias and agreement using simulated solutions and adult blood. Biol Res Nurs 3:210-21