Feeding by a nasogastric/orogastric (NG/OG) tube is preferred when the gastrointestinal system is functional and the need for assisted feeding is expected to be short-term. It is estimated that approximately one million enteral tubes are placed in adults and children in the United States annually. Preliminary studies in children show that between 21% and 44% of these tubes are placed incorrectly. When tubes are out of place, children can be seriously harmed, causing increased morbidity and occasionally death. Tube placement in children is especially understudied. Increasing the safety of NG/OG feeding in this population requires knowledge development in three areas---predicting the insertion distance for correct tube placement, determining tube position, and maintaining correct tube positioning. The proposed study addresses the first two of these knowledge needs. Goals are to determine the best method to predict the insertion distance for placing NG/OG tubes and to determine the best clinical methods of testing the location of NG/OG tubes once they are inserted. In addition, because the CO2 monitor has not been adequately tested previously, this study will provide critical preliminary information about this method. The sample will be 300 hospitalized children equal to or more than 100 months of age requiring gastric tubes. Subjects will have their tubes placed using one of three randomly assigned insertion-length predictors: age-related, height-based; nose-earxiphoid; or nose-ear midumbilicus. Immediately after insertion the position of the tube will be tested for unsuspected misplacement into the respiratory tree by measuring carbon dioxide (CO2) levels within the tube. Next pH and bilirubin levels of tube aspirate will be measured to detect gastric or intestinal location. Actual tube location will then be determined by abdominal radiograph to assess the adequacy of both the insertion length predictors and placement locating methods. Logistic regression will be used to compare the proportions of unsuspected misplacements among the insertion-length predictors and to compare the accuracies among the placement-locating methods. Results from this study will increase the safety of using gastric tubes in young children.

Agency
National Institute of Health (NIH)
Institute
National Institute of Nursing Research (NINR)
Type
Research Project (R01)
Project #
5R01NR008111-02
Application #
6937686
Study Section
Special Emphasis Panel (ZRG1-NSCF (01))
Program Officer
Jett, Kathleen
Project Start
2004-09-01
Project End
2009-05-31
Budget Start
2005-06-01
Budget End
2006-05-31
Support Year
2
Fiscal Year
2005
Total Cost
$260,580
Indirect Cost
Name
Indiana University-Purdue University at Indianapolis
Department
Other Health Professions
Type
Schools of Nursing
DUNS #
603007902
City
Indianapolis
State
IN
Country
United States
Zip Code
46202
Ellett, Marsha L Cirgin; Cohen, Mervyn D; Croffie, Joseph M B et al. (2014) Comparing bedside methods of determining placement of gastric tubes in children. J Spec Pediatr Nurs 19:68-79
Ellett, Marsha L Cirgin; Cohen, Mervyn D; Perkins, Susan M et al. (2012) Comparing methods of determining insertion length for placing gastric tubes in children 1 month to 17 years of age. J Spec Pediatr Nurs 17:19-32
Cirgin Ellett, Marsha L; Cohen, Mervyn D; Perkins, Susan M et al. (2011) Predicting the insertion length for gastric tube placement in neonates. J Obstet Gynecol Neonatal Nurs 40:412-21
Crisp, Cheryl L (2006) Esophageal nasogastric tube misplacement in an infant following laser supraglottoplasty. J Pediatr Nurs 21:454-5
Ellett, Marsha L Cirgin; Croffie, Joseph M B; Cohen, Mervyn D et al. (2005) Gastric tube placement in young children. Clin Nurs Res 14:238-52