The proposed study is a direct outgrowth of the research carried out over the past six years using a neonatal piglet model. Our research strongly indicates that the advantage of Magnetoencephalography (MEG) over Electroencephalography (EEG) should be clearest in an area that has thus far received little attention in non-invasive studies of brain functions, i.e. in the area of human neonatal brain research. Unlike the adults, the skull of the infants has fontanels and sutures which may be abnormally large in pathological cases. Our previous and ongoing studies imply that these openings should highly distort EEG, but not MEG signals. Moreover, the size of the fontanels and sutures as well as thickness of the scalp and skull change with age. These factors confer advantages to MEG, since it is insensitive to the skull, and by the same token to the scalp as well. In addition, the infant's skull and scalp are thin (2 mm for skull and 1 mm for scalp at birth). This makes it possible to measure the cortical activity with an exquisite sensitivity and spatial resolution at a distance of 3-4 mm from the brain surface using a special MEG sensor such as the microSQUID available in our laboratory and the babySQUID being developed by us with an SBIR phase I support. We will compare MEG and EEG in our piglet model in order to help develop the application of MEG in assessing brain functions of infants in both health and disease. The scalp and skull appear to be """"""""transparent"""""""" to MEG signals since the signals above the scalp, skull and cortex are very similar unlike EEG. EEG signals are clearly distorted by defects in the skull such as a hole mimicking the fontanel in infants. Experimental and theoretical studies will be carried out to provide understanding of how the distortion is produced, and how the skull and scalp differentially attenuate EEG signals produced by sources at different depths. The insensitivity of MEG to skull defects will be quantitatively assessed by comparing the somatic evoked magnetic field (SEF) on the scalp and cortex, and (2) by evaluating how well the cortical SEF can be predicted from scalp SEF. The sensitivity of MEG measurements will be evaluated in a developmental study, by measuring the signal-to-noise ratio of SEFs as a function of age, so that the results can be used to extrapolate the signals expected from human infants using the babySQUID. Our ongoing study has shown that the sensitivity of the microSQUID is sufficiently high to measure the synchronized population spikes due to thalamocortical axonal terminals and excitatory cortical neurons. It is undoubtedly extremely important if such signals can be seen in infants. Thus, we will solidify this finding. The spatial resolution will be evaluated by obtaining an estimate of the current distribution in the cortex with a simple technique and the estimated active areas will be verified with intracortical recordings. The current imaging technique will be also used to test whether it can reveal a mass lesion in the cortex as a relatively silent area and the surrounding penumbra as an area of hyperexcitability in a current image of spontaneous activity over the cortex. We hope to use these results as the basis for planning an infant study which will be started as soon as the babySQUID becomes available.

Agency
National Institute of Health (NIH)
Institute
National Institute of Neurological Disorders and Stroke (NINDS)
Type
Research Project (R01)
Project #
2R01NS030968-07A1
Application #
6328294
Study Section
Special Emphasis Panel (ZRG1-BDCN-1 (01))
Program Officer
Heetderks, William J
Project Start
1993-08-01
Project End
2005-05-31
Budget Start
2001-06-01
Budget End
2002-05-31
Support Year
7
Fiscal Year
2001
Total Cost
$306,693
Indirect Cost
Name
University of New Mexico
Department
Neurology
Type
Schools of Medicine
DUNS #
829868723
City
Albuquerque
State
NM
Country
United States
Zip Code
87131
Murakami, Shingo; Okada, Yoshio (2015) Invariance in current dipole moment density across brain structures and species: physiological constraint for neuroimaging. Neuroimage 111:49-58
Tanosaki, Masato; Ishibashi, Hideaki; Zhang, Tongsheng et al. (2014) Effective connectivity maps in the swine somatosensory cortex estimated from electrocorticography and validated with intracortical local field potential measurements. Brain Connect 4:100-11
Zhang, Tongsheng; Okada, Yoshio (2006) Recursive artifact windowed-single tone extraction method (RAW-STEM) as periodic noise filter for electrophysiological signals with interfering transients. J Neurosci Methods 155:308-18
Mun-Bryce, Sheila; Roberts, Lisa; Bartolo, Anton et al. (2006) Transhemispheric depolarizations persist in the intracerebral hemorrhage swine brain following corpus callosal transection. Brain Res 1073-1074:481-90
Flemming, Lars; Wang, Yaozhi; Caprihan, Arvind et al. (2005) Evaluation of the distortion of EEG signals caused by a hole in the skull mimicking the fontanel in the skull of human neonates. Clin Neurophysiol 116:1141-52
Wang, Yaozhi; Hosler, Gregory; Zhang, Tongsheng et al. (2005) Effects of temporary bilateral ligation of the internal carotid arteries on the low- and high-frequency somatic evoked potentials in the swine. Clin Neurophysiol 116:2420-8
Ikeda, Hiroaki; Wang, Yaozhi; Okada, Yoshio C (2005) Origins of the somatic N20 and high-frequency oscillations evoked by trigeminal stimulation in the piglets. Clin Neurophysiol 116:827-41
Okada, Y; Ikeda, I; Zhang, T et al. (2005) High-frequency signals (> 400 hz): a new window in electrophysiological analysis of the somatosensory system. Clin EEG Neurosci 36:285-92
Mun-Bryce, Sheila; Wilkerson, Arika; Pacheco, Bernadette et al. (2004) Depressed cortical excitability and elevated matrix metalloproteinases in remote brain regions following intracerebral hemorrhage. Brain Res 1026:227-34
Mun-Bryce, Sheila; Roberts, Lisa J M; Hunt, W Curtis et al. (2004) Acute changes in cortical excitability in the cortex contralateral to focal intracerebral hemorrhage in the swine. Brain Res 1026:218-26

Showing the most recent 10 out of 20 publications