The overall aims of this project are to provide a comprehensive and quantitative description of water diffusion in human brain which can be used to explain the variations in water diffusion that occur in normal and pathological conditions and that produce contrast in diffusion weighted MR images. There is now compelling evidence that water diffusion variations are of general interest and importance in a variety of normal and disease conditions.
We aim specifically to understand the basis for the changes that occur in diffusion weighted imaging studies of stroke, seizure and neuronal activation.
We aim to perform a series of exhaustive measurements of water diffusion properties in normal human brains. These studies will make use of the efficiency for collecting complete sets of data of advanced echo planar imaging techniques in humans to obtain measurements of the apparent diffusion coefficient (ADC) of tissue water, the degree to which diffusion is restricted, and assessments of the degree of diffusion anisotropy. These measurements will be used to infer the sizes of water compartments, the rates of exchange between them, and their intrinsic diffusion coefficients in brain tissues. Improved navigator echo methods will be implemented as well to permit high resolution diffusion images without echo planar acquisition. Measurements will also be made of the detailed nature of the transverse decay of tissue magnetization to permit the decomposition into component decay rates. Images of individual components of these so-called relaxation spectra will be produced and these should reveal correlative information on the spatial extent and exchange of different water environments. These measurements will be complemented with detailed studies of ADC in rat brain models of seizure and electroshock in which correlative electrophysiological measurements will be acquired. The threshold for observing diffusion changes following very brief stimulations will be established. We will also perform high resolution q space imaging of ex vivo preparations of excised rat optic nerve, subjected to different osmotic manipulations, to evaluate the effects of water volume shifts and other changes; and we will continue our extensive computer and theoretical modeling of water diffusion in restricted and compartmented systems to provide quantitative interpretations of these and other clinical observations. We will thereby obtain the information necessary to interpret water diffusion behavior in the brain, to guide the optimal use of MR imaging techniques in patient management and for developing models of tissue water diffusion to more fully explain the MRI changes seen in patients with stroke and other conditions.

Agency
National Institute of Health (NIH)
Institute
National Institute of Neurological Disorders and Stroke (NINDS)
Type
Research Project (R01)
Project #
5R01NS034834-04
Application #
2892037
Study Section
Diagnostic Radiology Study Section (RNM)
Program Officer
Heetderks, William J
Project Start
1996-08-15
Project End
2001-04-30
Budget Start
1999-05-01
Budget End
2001-04-30
Support Year
4
Fiscal Year
1999
Total Cost
Indirect Cost
Name
Yale University
Department
Radiation-Diagnostic/Oncology
Type
Schools of Medicine
DUNS #
082359691
City
New Haven
State
CT
Country
United States
Zip Code
06520
Shi, Zhaoyue; Wu, Ruiqi; Yang, Pai-Feng et al. (2017) High spatial correspondence at a columnar level between activation and resting state fMRI signals and local field potentials. Proc Natl Acad Sci U S A 114:5253-5258
Colvin, Daniel C; Loveless, Mary E; Does, Mark D et al. (2011) Earlier detection of tumor treatment response using magnetic resonance diffusion imaging with oscillating gradients. Magn Reson Imaging 29:315-23
Xu, Junzhong; Xie, Jingping; Jourquin, Jerome et al. (2011) Influence of cell cycle phase on apparent diffusion coefficient in synchronized cells detected using temporal diffusion spectroscopy. Magn Reson Med 65:920-6
Colvin, Daniel C; Jourquin, Jerome; Xu, Junzhong et al. (2011) Effects of intracellular organelles on the apparent diffusion coefficient of water molecules in cultured human embryonic kidney cells. Magn Reson Med 65:796-801
Xu, Junzhong; Does, Mark D; Gore, John C (2011) Dependence of temporal diffusion spectra on microstructural properties of biological tissues. Magn Reson Imaging 29:380-90
Gore, John C; Xu, Junzhong; Colvin, Daniel C et al. (2010) Characterization of tissue structure at varying length scales using temporal diffusion spectroscopy. NMR Biomed 23:745-56
Atuegwu, Nkiruka C; Gore, John C; Yankeelov, Thomas E (2010) The integration of quantitative multi-modality imaging data into mathematical models of tumors. Phys Med Biol 55:2429-49
Heemskerk, Anneriet M; Sinha, Tuhin K; Wilson, Kevin J et al. (2010) Repeatability of DTI-based skeletal muscle fiber tracking. NMR Biomed 23:294-303
Xu, Qing; Anderson, Adam W; Gore, John C et al. (2010) Efficient anisotropic filtering of diffusion tensor images. Magn Reson Imaging 28:200-11
Lee, Robert E; Welch, E Brian; Cobb, Jared G et al. (2009) Implementation of a semi-automated post-processing system for parametric MRI mapping of human breast cancer. J Digit Imaging 22:424-36

Showing the most recent 10 out of 27 publications