The Department of Radiology and Radiological Sciences at Vanderbilt University Medical Center has been investigating polychromatic phase-contrast radiography (PC-R) for several years. This technique has many potential uses in medical imaging as a new contrast mechanism for soft tissue imaging. Unlike laboratories utilizing a Synchroton light source (which will not be available for routine medical facilities), our technique utilizes the concept of spatial coherence, rather than temporal coherence, to obtain images strongly influenced by phase effects. The major limitation of the technique is the low tube output of the microfocal X-ray tube needed for PC-R. This project proposes to partner the investigators in Radiology who have been developing PC-R techniques with an X-ray source available at the Free Electron Laboratory (FEL) facility located on the Vanderbilt campus through a new collaboration between physicists at the FEL laboratory and the imaging researchers in the PC-R laboratory. The newly-developed X-ray source is completely independent of the Free Electron Laser itself and has been designed to function as a """"""""table-top"""""""" source that could be generally available to medical facilities. The X-ray beam produced by this source is largely monochromatic and has an extremely high spatial coherence. In addition, it has been designed to provide a high X-ray flux. These 3arameters make it a nearly-ideal source for PC-R. The project will initially optimize the imaging parameters for monochromatic PC-R with the unique X-ray source, by investigating different geometries and energies. Once the technique has been optimized, monochromatic PC-R will be compared to absorption radiography (with both the monochromatic source and with a traditional mammography machine) on surgical breast specimens. Image quality of all images will be judged by an experienced mammographer.

Agency
National Institute of Health (NIH)
Institute
National Cancer Institute (NCI)
Type
Exploratory/Developmental Grants (R21)
Project #
5R21CA109241-02
Application #
6918690
Study Section
Diagnostic Imaging Study Section (DMG)
Program Officer
Baker, Houston
Project Start
2004-08-01
Project End
2008-07-31
Budget Start
2005-08-01
Budget End
2008-07-31
Support Year
2
Fiscal Year
2005
Total Cost
$203,850
Indirect Cost
Name
Vanderbilt University Medical Center
Department
Radiation-Diagnostic/Oncology
Type
Schools of Medicine
DUNS #
004413456
City
Nashville
State
TN
Country
United States
Zip Code
37212
Donnelly, Edwin F; Lewis, Kenneth G; Wolske, Kristy M et al. (2006) Characterization of the phase-contrast radiography edge-enhancement effect in a cabinet x-ray system. Phys Med Biol 51:21-30