Obesity has reached epidemic levels in the U.S., with 66% of adults overweight and 32% of adults obese. The research uses the new technique of three-dimensional (3 D) photonic scanning to create and validate an instrument that rapidly assesses obesity in clinical and field settings.
The first aim i s to develop a portable computer vision system of body imaging for 3 D surface imaging of the human body. The hardware system is designed from off-the- shelf components such as digital cameras, projectors, and personal computer. Algorithms for the 3D data are being developed and refined for calculation and system calibration for a small instrument.
The second aim i s to develop algorithms for surface reconstruction from 3D data in order to define a proper surface representation and to reconstruct a 3D model of the human body from incomplete and noisy data.
The third aim begins the human measurement testing in 120 adults.
Aim 3 is to estimate the size and shape of the reconstructed human body by a portable body imager and compare to current methods that assess obesity. Anthropometric parameters will be computed by a 3 second body scan via imaging and then compared to other methods of obesity assessment including BMI, waist circumference, sagittal abdominal diameter, bioimpedence, hydrodensitometry, dual energy X-ray absorptiometry, and air displacement plethysmography.
The final aim i s to validate body imaging as an indicator of central obesity (fat in the abdominal region, as opposed to subcutaneous depots) in a subset of 60 subjects because it is the abdominal fat that is most associated with health risks such as diabetes. Abdominal fat tissue as detected by magnetic resonance imaging scans will be compared to that calculated from 3 D body imaging. In sum, the non-contact, noninvasive nature of this new portable body scanner will produce a quick, inexpensive and objective measure of body size and type of obesity.

Agency
National Institute of Health (NIH)
Institute
National Institute of Diabetes and Digestive and Kidney Diseases (NIDDK)
Type
Exploratory/Developmental Grants (R21)
Project #
5R21DK081206-03
Application #
7677970
Study Section
Special Emphasis Panel (ZHL1-CSR-J (S1))
Program Officer
Horlick, Mary
Project Start
2007-09-15
Project End
2011-08-31
Budget Start
2009-09-01
Budget End
2011-08-31
Support Year
3
Fiscal Year
2009
Total Cost
$204,454
Indirect Cost
Name
University of Texas Austin
Department
Social Sciences
Type
Schools of Arts and Sciences
DUNS #
170230239
City
Austin
State
TX
Country
United States
Zip Code
78712
Sun, Jingjing; Xu, Bugao; Freeland-Graves, Jeanne (2016) Automated quantification of abdominal adiposity by magnetic resonance imaging. Am J Hum Biol 28:757-766
Lee, Jane J; Freeland-Graves, Jeanne H; Pepper, M Reese et al. (2015) Efficacy of thigh volume ratios assessed via stereovision body imaging as a predictor of visceral adipose tissue measured by magnetic resonance imaging. Am J Hum Biol 27:445-57
Lee, Jane J; Freeland-Graves, Jeanne H; Pepper, M Reese et al. (2015) Prediction of Android and Gynoid Body Adiposity via a Three-dimensional Stereovision Body Imaging System and Dual-Energy X-ray Absorptiometry. J Am Coll Nutr 34:367-77
Lee, Jane J; Freeland-Graves, Jeanne H; Pepper, M Reese et al. (2014) Predictive equations for central obesity via anthropometrics, stereovision imaging and MRI in adults. Obesity (Silver Spring) 22:852-62
Pepper, M Reese; Freeland-Graves, Jeanne H; Yu, Wurong et al. (2010) Validation of a 3-dimensional laser body scanner for assessment of waist and hip circumference. J Am Coll Nutr 29:179-88
Yu, Wurong; Xu, Bugao (2010) A Portable Stereo Vision System for Whole Body Surface Imaging. Image Vis Comput 28:605-613
Pepper, M Reese; Freeland-Graves, Jeanne H; Yu, Wurong et al. (2010) Evaluation of a rotary laser body scanner for body volume and fat assessment. J Test Eval 39:1-6
Xu, Bugao; Yu, Wurong; Yao, Ming et al. (2009) Three-dimensional surface imaging system for assessing human obesity. Opt Eng 48:nihpa156427