Functional Magnetic Resonance Imaging (fMRI) has revolutionized neuroscience by mapping activity throughout the brain without the use of radioactive tracers, electrical probes or other invasive procedures. The dominant method for fMRI, Blood Oxygenation Level Dependent (BOLD) imaging, is sensitive to changes in blood oxygenation that occur in response to brain activity. While BOLD imaging represents a major advance in brain mapping, this method has a number of significant limitations including poor spatial resolution, low signal levels, limited contrast and severe image artifacts. These limitations derive from the fact that BOLD contrast is slow to develop, resulting in a loss of signal and a sensitivity to image artifacts. Our group has developed a new steady-state fMRI method that has the potential to overcome these limitations by sensing changes in blood oxygenation more directly. The steady-state signal can be made intrinsically sensitive to oxygenation, allowing data to be gathered under significantly better imaging conditions. Steady-state fMRI is expected to produce artifact-free images with high spatial resolution, and provide high signal levels with excellent functional contrast. The work described in this proposal will take the first steps in transforming this nascent method into a practical tool for neuroscience experiments. Development of the imaging methodology will be accompanied by analysis of the spatial and temporal characteristics of the functional signal, as well as comparison with standard BOLD imaging. This proposal will focus on the visual system as a well-characterized testbed of widespread interest in the neuroscience community. Development will be guided by the specific goals of spatial and temporal characterization in the visual cortex.

Agency
National Institute of Health (NIH)
Institute
National Institute of Biomedical Imaging and Bioengineering (NIBIB)
Type
Exploratory/Developmental Grants (R21)
Project #
5R21EB002969-02
Application #
6798603
Study Section
Special Emphasis Panel (ZRG1-SSS-X (50))
Program Officer
Mclaughlin, Alan Charles
Project Start
2003-09-05
Project End
2006-02-28
Budget Start
2004-09-01
Budget End
2006-02-28
Support Year
2
Fiscal Year
2004
Total Cost
$240,000
Indirect Cost
Name
Stanford University
Department
Engineering (All Types)
Type
Schools of Engineering
DUNS #
009214214
City
Stanford
State
CA
Country
United States
Zip Code
94305
Stikov, Nikola; Perry, Lee M; Mezer, Aviv et al. (2011) Bound pool fractions complement diffusion measures to describe white matter micro and macrostructure. Neuroimage 54:1112-21
Lee, Jongho; Lustig, Michael; Kim, Dong-hyun et al. (2009) Improved shim method based on the minimization of the maximum off-resonance frequency for balanced steady-state free precession (bSSFP). Magn Reson Med 61:1500-6
Lee, Jongho; Shahram, Morteza; Schwartzman, Armin et al. (2007) Complex data analysis in high-resolution SSFP fMRI. Magn Reson Med 57:905-17
Lee, Jongho; Santos, Juan M; Conolly, Steven M et al. (2006) Respiration-induced B0 field fluctuation compensation in balanced SSFP: real-time approach for transition-band SSFP fMRI. Magn Reson Med 55:1197-201
Miller, Karla L; Smith, Stephen M; Jezzard, Peter et al. (2006) High-resolution FMRI at 1.5T using balanced SSFP. Magn Reson Med 55:161-70
Cunningham, Charles H; Arai, Takayasu; Yang, Phillip C et al. (2005) Positive contrast magnetic resonance imaging of cells labeled with magnetic nanoparticles. Magn Reson Med 53:999-1005