The tumor microenvironment (TME) is the chemical and biological background that affects tumor malignancy, proliferation and metastatic activity because of chaotic angiogenesis tumors growing to become less oxygenated (low pO2) and more acidic (low pH). While pO2 and pH are known to be important factors for tumor growth and treatment, interstitial Pi has been recently identified as a new signaling molecule of importance in tumorigenesis. Newly synthesized stable paramagnetic molecules, spin probes, permit simultaneous in vivo monitoring of interstitial pO2, extracellular pH (pHe) and concentration of interstitial inorganic phosphate (Pi) using Electron Paramagnetic Resonance (EPR). Because tumors are highly heterogeneous, spectral-spatial EPR imaging is required to spatially resolve the parameters of interest. Spatial resolution is defined by EPR sensitivity. The amount of the spin probe molecules within a voxel decreases as spatial resolution is cubed, and may become undetectable if too small. Sensitivity also directly translates into functional resolution, the accuracy with which pH, pO2, and Pi can be measured. The proposal by the PI and his colleagues for a Rapid Scan (RS) EPR technique has been explored at 250 MHz frequency and showed improvement in signal-to-noise ratio up to two orders of magnitude compared to the standard field-modulated continuous wave (CW) method. An additional order of magnitude signal enhancement can be achieved for trityl-based multifunctional probes by increasing EPR frequency to 700 -800 MHz (optimal for small animal RS EPR studies) and scan frequency to 50-100 kHz (the current mathematical algorithm limits the upper scan frequency to about 10 kHz). RS EPR sensitivity enhancement will require both hardware (SA1) and software (SA2) developments. In addition, novel 4D spectral- spatial algorithm will be further developed to enable multi-functional multi-line EPR imaging, since the standard filtered backprojection (FBP) reconstruction fails to work with multi-functional spin probes that have a comparatively broad multi-line EPR spectra. A newly developed multi-functional EPR imager will first be tested in vitro on standard samples with known geometry, pO2, pH, and Pi patterns, followed by in vivo proof-of-concept imaging. A colony of PyMT transgenic mice will be used that spontaneously-develop breast cancer to perform the rapid scan multifunctional imaging and construct spatially-resolved pO2, pH, and Pi profiles of TME and normal mammary gland. We anticipate to achieve physiologically significant voxel-specific functional sensitivities of about 1-2 mmHg of pO2, 0.05 pH units and 0.1 mM of inorganic phosphate. Estimated spatial resolution will be smaller than 200 ?m. In summary, the success of this project may have a significant impact on the future of in vivo functional imaging to study TME and beyond.

Public Health Relevance

This project will develop new imaging modality which enables multifunctional mapping of physiologically-critical parameters, such as pH, oxygen, and interstitial inorganic phosphate (Pi). These are important markers for studying tumorigenesis and treatment efficacy. A multifunctional imager will be developed and tested on PyMT transgenic mice, which will spontaneously-develop breast cancer.

Agency
National Institute of Health (NIH)
Institute
National Institute of Biomedical Imaging and Bioengineering (NIBIB)
Type
Exploratory/Developmental Grants (R21)
Project #
5R21EB022775-02
Application #
9281733
Study Section
Biomedical Imaging Technology Study Section (BMIT)
Program Officer
Atanasijevic, Tatjana
Project Start
2016-06-01
Project End
2019-05-31
Budget Start
2017-06-01
Budget End
2019-05-31
Support Year
2
Fiscal Year
2017
Total Cost
Indirect Cost
Name
West Virginia University
Department
Biochemistry
Type
Schools of Medicine
DUNS #
191510239
City
Morgantown
State
WV
Country
United States
Zip Code
26506
Tseytlin, Mark; Stolin, Alexander V; Guggilapu, Priyaankadevi et al. (2018) A combined positron emission tomography (PET)-electron paramagnetic resonance imaging (EPRI) system: initial evaluation of a prototype scanner. Phys Med Biol 63:105010
Sanzhaeva, Urikhan; Xu, Xuan; Guggilapu, Priyaankadevi et al. (2018) Imaging of Enzyme Activity by Electron Paramagnetic Resonance: Concept and Experiment Using a Paramagnetic Substrate of Alkaline Phosphatase. Angew Chem Int Ed Engl 57:11701-11705
Epel, Boris; Sundramoorthy, Subramanian V; Krzykawska-Serda, Martyna et al. (2017) Imaging thiol redox status in murine tumors in vivo with rapid-scan electron paramagnetic resonance. J Magn Reson 276:31-36
Tseytlin, Mark (2017) Full cycle rapid scan EPR deconvolution algorithm. J Magn Reson 281:272-278
Möser, J; Lips, K; Tseytlin, M et al. (2017) Using rapid-scan EPR to improve the detection limit of quantitative EPR by more than one order of magnitude. J Magn Reson 281:17-25
Tseytlin, Mark (2017) Concept of Phase Cycling in Pulsed Magnetic Resonance Using Sinusoidal Magnetic Field Modulation. Z Phys Chem (N F) 231:689-703
Khramtsov, Valery V; Bobko, Andrey A; Tseytlin, Mark et al. (2017) Exchange Phenomena in the Electron Paramagnetic Resonance Spectra of the Nitroxyl and Trityl Radicals: Multifunctional Spectroscopy and Imaging of Local Chemical Microenvironment. Anal Chem 89:4758-4771
Biller, Joshua R; Mitchell, Deborah G; Tseytlin, Mark et al. (2016) Rapid Scan Electron Paramagnetic Resonance Opens New Avenues for Imaging Physiologically Important Parameters In Vivo. J Vis Exp :