Patients with end-stage kidney and liver disease as well as acute organ failure are unable to maintain the necessary clearance of toxins and require blood-purification techniques or organ transplant. Over 400,000 end-stage renal disease (ESRD) patients receive regular hemodialysis (HD) treatments in the United States. A smaller number receive artificial liver support therapy for detoxification and liver failure. These blood purification techniques place an extremely high financial burden on our medical system with sometimes questionable efficacy and relatively poor quality of life. ESRD treatment alone accounts for 7% of all Medicare spending ($31B). The membrane and adsorption technology behind these treatments has been slow to evolve over the last few decades, limiting the opportunity to make significant improvements. Graphene oxide (GO) has the potential to radically improve and change hemodialysis and liver support systems because GO bilayers are the thinnest possible molecular sieve and nanoscale-spaced GO stacks offer unparalleled adsorptive capacity. The scientific premise behind the use of GO nanoengineered laminates for the clearance of water-soluble and albumin- bound toxins is two-fold. First, prior work has demonstrated that the use of ultrathin nanoporous membranes enables the reduction of laboratory-scale dialyzers by two orders of magnitude compared to conventional polymeric membranes due to dramatically increased permeability, while maintaining size-selectivity. We hypothesize that GO nanoengineered laminate membranes will further reduce required membrane area by at least another order of magnitude based on thinness (<10nm) and increased permeability. Second, albumin-bound toxins have traditionally been removed using anion- exchange columns or porous matrices of activated carbon. Nanospaced GO laminates offer a theoretical limit on surface area within a fixed volume that is likely to exceed conventional adsorbent materials by orders of magnitude. The two aims in the proposal will test both hypotheses.
Aim 1 will investigate use of GO to clear water-soluble toxins from plasma, while Aim 2 will investigate the clearance of albumin-bound toxins via albumin dialysis and adsorption to a GO laminate stack. Success in these aims will enable novel device design and treatment flexibility that may include wearable and more efficient therapies with higher quality of life for patients with kidney and liver disease.

Public Health Relevance

One of the primary limitations in the treatment of kidney and liver failure is extracorporeal artificial blood purification. This project will test the hypothesis that a new graphene oxide nanoengineered laminate can serve as a highly efficient membrane filter and sorbent matrix to remove toxins from the blood. This new material could reduce dialyzer sizes by orders of magnitude, opening the door to miniaturized devices and new methods of treatment.

Agency
National Institute of Health (NIH)
Institute
National Institute of Biomedical Imaging and Bioengineering (NIBIB)
Type
Exploratory/Developmental Grants (R21)
Project #
1R21EB023527-01A1
Application #
9387567
Study Section
Nanotechnology Study Section (NANO)
Program Officer
Rampulla, David
Project Start
2017-07-15
Project End
2019-04-30
Budget Start
2017-07-15
Budget End
2018-04-30
Support Year
1
Fiscal Year
2017
Total Cost
Indirect Cost
Name
University of Florida
Department
Engineering (All Types)
Type
Biomed Engr/Col Engr/Engr Sta
DUNS #
969663814
City
Gainesville
State
FL
Country
United States
Zip Code
32611