This proposed project is intended to develop a novel, low-cost, compact, point-of-care (POC) ultrasound system to assess myopia severity and progression in vivo. Myopia prevalence is increasing worldwide and pathologic myopia is one of the leading causes of blindness. Myopia originates from structural and mechanical changes in the sclera that precede vision-threatening ocular changes. Currently, no method exists to assess myopia progression and severity quantitatively in vivo, and this project seeks to fill this gap. The POC instrument to be developed will consist of a single-element, spherically focused transducer operating at an 80-MHz center frequency mounted in a handheld probe and connected to a computer equipped with dedicated software, hardware, and a touch screen for ease of use using a graphical user interface. The POC instrument will collect RF, A-line data at a high pulse-repetition frequency while in direct contact with the anterior sclera. The RF data will be processed using QUS methods to derive so- called QUS estimates associated with the elastic and microstructural properties of the sclera. The QUS estimates will be based on the backscatter coefficient and envelope statistics as well as on highly- innovative passive elastography. The POC instrument will be portable, low-cost, real-time, and nonionizing. It will be very similar to pachymeters currently used by ophthalmologists for biometric measurements, which will facilitate its adoption by clinicians. In Year 2, the POC instrument will be deployed at our collaborating clinical site, the Singapore Eye Research Institute, to acquire and process data from 100 patients during a prospective clinical study aimed at assessing the value of the POC instrument for evaluating high-myopia patients. Specifically, the clinical study will test the ability of the system to predict myopia severity and progression. If successful, these studies will not only advance myopia knowledge significantly, but, equally important, the proposed POC instrument will revolutionize care for myopia patients by providing a low-cost, easy-to-use, and safe means to assess disease severity and progression.

Public Health Relevance

A novel, low-cost, non-ionizing, non-invasive, ultrasound-based, point-of-care (POC) instrument is proposed to assess the severity and progression of myopia. Myopia prevalence is increasing worldwide, and high pathologic myopia is a leading cause of blindness. The POC instrument will provide real-time, A- line, radio-frequency (RF) data at a high pulse-repetition frequency from the anterior sclera. RF data will be processed in real-time using quantitative ultrasound methods to assess the elastic and microstructural properties of the anterior sclera, which are hypothesized to be altered by myopia development. The POC instrument can be used in vivo during routine ophthalmology examinations, and its clinical value for myopia assessment will be evaluated in a study of 100 patients.

Agency
National Institute of Health (NIH)
Institute
National Institute of Biomedical Imaging and Bioengineering (NIBIB)
Type
Exploratory/Developmental Grants (R21)
Project #
1R21EB028084-01A1
Application #
9903615
Study Section
Emerging Imaging Technologies and Applications Study Section (EITA)
Program Officer
King, Randy Lee
Project Start
2020-09-15
Project End
2022-08-31
Budget Start
2020-09-15
Budget End
2022-08-31
Support Year
1
Fiscal Year
2020
Total Cost
Indirect Cost
Name
Riverside Research Institute
Department
Type
DUNS #
046822615
City
New York
State
NY
Country
United States
Zip Code
10038