The goal of the proposed research is to develop a platform technology for simultaneous detection of multiple analytes with better efficiency and lower cost. Currently, immunoassays are extensively used in biomedical research, clinical diagnostics, food/water safety testing, and biological warfare defense. Although they can be performed in a microplate (e.g. 96 wells) to increase sample throughput, the immunoassay in each well is generally limited to one analyte per test. Such a format is inefficient and not cost-effective for the requirement to detect multiple analytes in a sample. For instance, a spectrum of toxic agents should be simultaneously monitored in foods and drinking water. Similarly, a set of biomarkers, rather than an individual biomarker, should be detected for a particular disease to enhance the accuracy. Therefore, a platform to detect multiple analytes simultaneously is desirable for better efficiency and lower cost.
The specific aims of the proposed research are to (1) design and optimize an array of microfluidic valves that are required for containing reagents, directing and regulating flows;(2) demonstrate the microfluidics-enabled multiplexed immunoassay array in the format of sandwich assays and study the effects of surface modification, flow rate, reagent concentration on the assay;and (3) validate the immunoassay array by detecting multiple analytes including toxins and biomarkers. The significance of the research lies in the following aspects. First, the proposed research will lead to a platform for simultaneous detection of multiple analytes. Such a capability will lead to efficient and cost- effective methods. Secondly, the microfluidic-enabled immunoassay array will have shorter analysis time and a reduction in the consumption of required sample and reagents. These advantages could have a significant impact since immunoassays are widely used in chemical, biological and clinical laboratories. Thirdly, the proposed research will result in a manufacturable process that allows mass production of low-cost, disposable devices. The ability to be disposable after a single use could have a tremendous impact to applications where cross-contamination of sequential samples is of concern.

Public Health Relevance

(provided by applicant): A platform technology capable of simultaneous detection of multiple analytes in one test can be used for simultaneously detecting of a wide range of toxic agents;such a capability is essential when US is facing with the potential threats of terrorism. It can also be exploited for screening a number of biomarkers associated with a disease;such a capability will lead to efficient and cost-effective medical diagnostics.

Agency
National Institute of Health (NIH)
Institute
National Center for Research Resources (NCRR)
Type
Exploratory/Developmental Grants (R21)
Project #
1R21RR026215-01A1
Application #
8164759
Study Section
Special Emphasis Panel (ZRR1-BT-7 (01))
Program Officer
Friedman, Fred K
Project Start
2011-08-20
Project End
2014-05-31
Budget Start
2011-08-20
Budget End
2012-05-31
Support Year
1
Fiscal Year
2011
Total Cost
$172,977
Indirect Cost
Name
University of Florida
Department
Engineering (All Types)
Type
Schools of Engineering
DUNS #
969663814
City
Gainesville
State
FL
Country
United States
Zip Code
32611
Xu, Xin; Liu, Ke; Fan, Z Hugh (2012) Microscale 2D separation systems for proteomic analysis. Expert Rev Proteomics 9:135-47
Liu, Ke; Gu, Pan; Hamaker, Kiri et al. (2012) Characterization of bonding between poly(dimethylsiloxane) and cyclic olefin copolymer using corona discharge induced grafting polymerization. J Colloid Interface Sci 365:289-95