Parallel en-face optical coherence microscopy with adaptive focus Guoqiang Li Abstract We propose a novel parallel nonstralational optical coherence microscopy (OCM) with adaptive focus for general high-speed high-resolution en-face biomedical imaging. Optical coherence tomography (OCT) has become an emerging imaging modality with high depth resolution. OCM is one kind of OCT imaging technique with better tranverse and depth resolution by using confocal architecture in the object arm. Typical OCT systems generate B-scan cross section images. In clinic, the users are more familiar with C-scan (en face) images. Parallel OCT imaging has been studied, but not in the OCM architecture. Furthermore, in the conventional OCT/OCM imaging, good tranverse resolution can be maintained only in the region close to the focal plane. Dynamic focusing can only be done by mechanic movement. To overcome these problems, here we propose to demonstrate, for the first time, a nontranslational parallel en-face OCM imaging instrument with adaptive focus. A programmable digital micromirror device is used for parallel confocal sampling, an electro-optic varifocal lens for rapid depth scanning, and a rapid CMOS camera with more than 7500 frames/s rate for data collection. With adaptive focusing, the transverse resolution is constant across the depth of imaging. The spatial resolution can be around 15m W 15m W 15m in three dimensions. The imaging depth is higher than that of the confocal or full-field OCT imaging alone. With the rapid speed of the digital micromirror device (microsecond), the vafifocal lens(ms), and the CMOS camera, the data acquisition speed is very high (7500 frames/s). The pixel dwell time is significantly increased. It allows lower excitation laser power, higher sensitivity, and less thermal damage. The signal-to-noise ratio would be higher than other full-field OCT imaging without confocal architecture. Since in the object arm, both longitudinal and transverse scannings are performed electro-optically without translational components, the moving effect of the sample due to mechanic vibration of the conventional imaging system can be avoided. The instrument provides a new tool to assess tissue and cell function and morphology in real time. In the proposed exploratory phase of this technology-driven project, we will perform experiments on general biologic relevant samples to demonstrate the functionality of the system. These samples include tissue phantoms based on gelatin embedded micro spheres covering a USAF 1951 target, onion skin, tadpole and ex vivo bovine eye. Images from biological samples will be compared to published OCT images and microscopy images of our corresponding thin sectioned samples.

Public Health Relevance

(provided by applicant): We have proposed a novel parallel nonstralational optical coherence microscopy (OCM) with adaptive focus for general high-speed high-resolution en-face biomedical imaging. Our research proposal currently focuses on demonstration the feasibility of this new technique. With adaptive focusing, the transverse resolution is constant across the depth of imaging. The spatial resolution can be around 15m W 15m W 15m in three dimensions. The imaging depth is higher than that of the confocal or full-field OCT imaging alone. With the rapid speed of the digital micromirror device (microsecond), the varifocal lens(ms), and the CMOS camera, the data acquisition speed is very high (7500 frames/s). The pixel dwell time is significantly increased. It allows lower excitation laser power, higher sensitivity, and less thermal damage. The signal-to-noise ratio would be higher than other full-field OCT imaging without confocal architecture. Since in the object arm, both longitudinal and transverse scannings are performed electro-optically without translational components, the moving effect of the sample due to mechanic vibration of the conventional imaging system can be avoided. The instrument provides a new tool to assess tissue and cell function and morphology in real time.

Agency
National Institute of Health (NIH)
Institute
National Center for Research Resources (NCRR)
Type
Exploratory/Developmental Grants (R21)
Project #
7R21RR026254-03
Application #
8514371
Study Section
Special Emphasis Panel (ZRR1-BT-7 (01))
Program Officer
Friedman, Fred K
Project Start
2010-08-15
Project End
2013-04-30
Budget Start
2012-01-01
Budget End
2012-04-30
Support Year
3
Fiscal Year
2011
Total Cost
$118,032
Indirect Cost
Name
Ohio State University
Department
Ophthalmology
Type
Schools of Medicine
DUNS #
832127323
City
Columbus
State
OH
Country
United States
Zip Code
43210
Lan, Gongpu; Li, Guoqiang (2017) Design of a k-space spectrometer for ultra-broad waveband spectral domain optical coherence tomography. Sci Rep 7:42353
Nayek, Prasenjit; Li, Guoqiang (2015) Superior electro-optic response in multiferroic bismuth ferrite nanoparticle doped nematic liquid crystal device. Sci Rep 5:10845
Choudhary, Amit; Li, Guoqiang (2014) Anisotropic shift of surface plasmon resonance of gold nanoparticles doped in nematic liquid crystal. Opt Express 22:24348-57
Zhao, Tingyu; Mauger, Thomas; Li, Guoqiang (2013) Optimization of wavefront-coded infinity-corrected microscope systems with extended depth of field. Biomed Opt Express 4:1464-71
Lin, Di; Xia, Kegui; Li, Ruxin et al. (2010) Radially polarized and passively Q-switched fiber laser. Opt Lett 35:3574-6
Lin, Di; Xia, Kegui; Li, Jianlang et al. (2010) Efficient, high-power, and radially polarized fiber laser. Opt Lett 35:2290-2