) The overall goal of the proposed research is the development of applicators for precise delivery of high intensity ultrasound to regions of the prostate containing cancer, with concurrent real-time thermal monitoring of the prostate and periprostatic tissues. The project represents a collaborative effort in which high-intensity applicators suitable for transurethral and interstitial use will be fabricated at University of California at San Francisco, and then tested in the in vitro and in vivo MRI studies by investigators at Stanford University. Three types of catheters suitable for transurethral use, differing in their degrees of acoustic focusing will be designed, fabricated and tested in the in vitro studies, these studies will determine the most promising design for practical prostate ablation. Evaluation criteria will include the speed of heating possible, the ability to perform conformal delivery of heating to desired regions, and ease of use. The most promising design or designs will then be tested in vive in a canine animal model with MR/ thermometry using phase-sensitive imaging. Correlative thermocouple measurements will be made during these studies, and a real-time thermometry reconstruction and display systems developed at Stanford will be adapted for thermal mapping of the prostate. Histologic studies of the in vive insonated prostatic and periprostatic tissues will be performed, and correlated to phase-sensitive, T2-weighted and contrast enhanced MR images, to determine the most effective procedure for imaging prostate tissue necrosis directly with MRI.

Agency
National Institute of Health (NIH)
Institute
National Cancer Institute (NCI)
Type
Exploratory/Developmental Grants Phase II (R33)
Project #
5R33CA088205-02
Application #
6514745
Study Section
Special Emphasis Panel (ZCA1-SRRB-Y (M1))
Program Officer
Farahani, Keyvan
Project Start
2001-06-01
Project End
2004-05-31
Budget Start
2002-06-01
Budget End
2003-05-31
Support Year
2
Fiscal Year
2002
Total Cost
$405,172
Indirect Cost
Name
Stanford University
Department
Radiation-Diagnostic/Oncology
Type
Schools of Medicine
DUNS #
800771545
City
Stanford
State
CA
Country
United States
Zip Code
94305
Rieke, Viola; Butts Pauly, Kim (2008) Echo combination to reduce proton resonance frequency (PRF) thermometry errors from fat. J Magn Reson Imaging 27:673-7
Pisani, Laura; Bammer, Roland; Glover, Gary (2007) Restricted field of view magnetic resonance imaging of a dynamic time series. Magn Reson Med 57:297-307
Kinsey, Adam M; Diederich, Chris J; Tyreus, P Daniel et al. (2006) Multisectored interstitial ultrasound applicators for dynamic angular control of thermal therapy. Med Phys 33:1352-63
Nau, William H; Diederich, Chris J; Ross, Anthony B et al. (2005) MRI-guided interstitial ultrasound thermal therapy of the prostate: a feasibility study in the canine model. Med Phys 32:733-43
Pisani, Laura J; Ross, Anthony B; Diederich, Chris J et al. (2005) Effects of spatial and temporal resolution for MR image-guided thermal ablation of prostate with transurethral ultrasound. J Magn Reson Imaging 22:109-18
Ross, Anthony B; Diederich, Chris J; Nau, William H et al. (2005) Curvilinear transurethral ultrasound applicator for selective prostate thermal therapy. Med Phys 32:1555-65
Diederich, C J; Nau, W H; Ross, A B et al. (2004) Catheter-based ultrasound applicators for selective thermal ablation: progress towards MRI-guided applications in prostate. Int J Hyperthermia 20:739-56
Ross, Anthony B; Diederich, Chris J; Nau, William H et al. (2004) Highly directional transurethral ultrasound applicators with rotational control for MRI-guided prostatic thermal therapy. Phys Med Biol 49:189-204