Despite the development of new imaging modalities, x-ray mammography remains the main tool for screening, diagnosis and management of breast cancers. However, the limited sensitivity and superimposition of calcifications and masses on the breast parenchyma have compromised its value in these procedures. Recent development of flat panel (FP) based cone beam CT (CBCT) techniques have initiated a new approach referred to as the dedicated or pendant geometry cone beam breast CT technique which couples high contrast sensitivity with true 3-D rendition of breast anatomy and lesions. However, although the spatial resolution offered by FP based CBCT is potentially higher than those provided by the conventional CT techniques, it is still significantly lower than those of mammographic imaging techniques as required for detecting and visualizing small calcifications. In this project, we propose to develop, investigate and evaluate a new technique referred to as the dual-resolution CBCT (DRCBCT) technique to allow the spatial resolution of the 3D breast images to be improved beyond those achievable with FPCBCT. With this technique, a FP detector is used to acquire full field CBCT images which are used to select a volume-of-interest (VOI). The breast is then re-positioned to have the VOI centered to the iso-center. A collimator is added to limit the x-ray field to the VOI and a small field of view CCD detector is used to acquire high resolution projection images for the VOI at an appropriate exposure level. Limited height, full width FP images are then obtained by re- scanning or by computing the re-projections from previously obtained FPCBCT images to fill in the truncated area as required for high resolution VOI CBCT. Because high resolution image acquisition and reconstruction are limited to the VOI, both patient dose and computation time can be kept at a reasonable level, making it more practical to implement and use for clinical applications. In the R21 phase (Year 1), we propose to investigate and demonstrate the feasibility of the dual resolution CBCT technique with computer simulation and bench top imaging experiments. In the R33 phase (Years 2, 3 and 4), we propose to construct, optimize and investigate a prototype system for dual resolution CBCT. Both phantom and patient images will be obtained to demonstrate the performance improvement by the dual resolution CBCT techniques and potential applications in the diagnosis and management of breast cancers. Successful development and investigation of the dual resolution CBCT technique may provide a powerful tool for 3-D breast imaging. The addition of high resolution capability, coupled with improved contrast sensitivity and the true 3-D nature of breast CT images may allow the dual resolution CBCT technique to replace and even surpass conventional mammography for improved diagnosis and management of breast cancers, including image guided biopsy, surgical planning, and needle localization. Proposal to be submitted to the NIH-NCI as R21/R33 project Title A Dual Resolution Cone Beam CT System for 3-D Breast Imaging Project Narrative Despite the development of new imaging modalities, x-ray mammography remains the main tool for screening, diagnosis and management of breast cancers. However, the limited sensitivity and superimposition of calcifications and masses on the breast parenchyma have compromised its value in these procedures. Recent development of flat panel (FP) based cone beam CT (CBCT) techniques have intitiated a new approach referred to as the dedicated or pendant geometry cone beam breast CT technique which couples high contrast senstivity with true 3-D rendition of breast anatomy and lesions. However, although the spatial resolution offered by FP based CBCT is potentially higher than those provided by the conventional CT techniques, it is still significantly lower than those of mammographic imaging techniques as required for detecting and visualizing small calcifications. In this project, we propose to develop, investigate and evaluate a new technique referred to as the dual-resolution CBCT (DRCBCT) technique to allow the spatial resolution of the 3D breast images to be improved beyond those achievable with FPCBCT. With this technique, a FP detector is used to acquire full field CBCT images which are used to select a volume-of-interest (VOI). The breast is then re-positioned to have the VOI centered to the iso-center. A collimator is added to limit the x-ray field to the VOI and a small field of view CCD detector is used to acquire high resolution projection images for the VOI at an appropriate exposure level. Limited height, full width FP images are then obtained by re- scanning or by computing the re-projections from previously obtained FPCBCT images to fill in the truncated area as required for high resolution VOI CBCT. Because high resolution image acquisition and reconstruction are limited to the VOI, both patient dose and computation time can be kept at a reasonable level, making it more practical to implement and use for clinical applications. In the R21 phase (Year 1), we propose to investigate and demonstrate the feasibility of the dual resolution CBCT technique with computer simulation and bench top imaging experiments. In the R33 phase (Years 2, 3 and 4), we propose to construct, optimize and investigate a prototype system for dual resolution CBCT. Both phantom and patient images will be obtained to demonstrate the performance improvement by the dual resolution CBCT techniques and potential applications in the diagnosis and management of breast cancers. Successful development and investigation of the dual resolution CBCT technique may provide a powerful tool for 3-D breast imaging. The addition of high resolution capability, coupled with improved contrast sensitivity and the true 3-D nature of breast CT images may allow the dual resolution CBCT technique to replace and even surpass conventional mammography for improved diagnosis and management of breast cancers, including image guided biopsy, surgical planning, and needle localization. ? ? ?

Agency
National Institute of Health (NIH)
Institute
National Cancer Institute (NCI)
Type
Exploratory/Developmental Grants Phase II (R33)
Project #
4R33CA124585-02
Application #
7689485
Study Section
Special Emphasis Panel (ZRG1-SBIB-J (51))
Program Officer
Croft, Barbara
Project Start
2007-09-01
Project End
2011-08-31
Budget Start
2008-09-01
Budget End
2009-08-31
Support Year
2
Fiscal Year
2008
Total Cost
$450,167
Indirect Cost
Name
University of Texas MD Anderson Cancer Center
Department
Radiation-Diagnostic/Oncology
Type
Other Domestic Higher Education
DUNS #
800772139
City
Houston
State
TX
Country
United States
Zip Code
77030
Lai, Chao-Jen; Zhong, Yuncheng; Yi, Ying et al. (2015) Radiation doses in volume-of-interest breast computed tomography--A Monte Carlo simulation study. Med Phys 42:3063-75
Zhong, Yuncheng; Lai, Chao-Jen; Wang, Tianpeng et al. (2015) A dual-view digital tomosynthesis imaging technique for improved chest imaging. Med Phys 42:5238-51
Shen, Youtao; Zhong, Yuncheng; Lai, Chao-Jen et al. (2013) Cone beam breast CT with a high pitch (75 ?m), thick (500 ?m) scintillator CMOS flat panel detector: visibility of simulated microcalcifications. Med Phys 40:101915
Shen, Youtao; Yi, Ying; Zhong, Yuncheng et al. (2011) High resolution dual detector volume-of-interest cone beam breast CT--Demonstration with a bench top system. Med Phys 38:6429-42
Yi, Ying; Lai, Chao-Jen; Han, Tao et al. (2011) Radiation doses in cone-beam breast computed tomography: a Monte Carlo simulation study. Med Phys 38:589-97
Liu, Xinming; Shaw, Chris C; Lai, Chao-Jen et al. (2011) Comparison of scatter rejection and low-contrast performance of scan equalization digital radiography (SEDR), slot-scan digital radiography, and full-field digital radiography systems for chest phantom imaging. Med Phys 38:23-33
Liu, Xinming; Lai, Chao-Jen; Whitman, Gary J et al. (2011) Effects of exposure equalization on image signal-to-noise ratios in digital mammography: a simulation study with an anthropomorphic breast phantom. Med Phys 38:6489-501
Liu, Xinming; Lai, Chao-Jen; Chen, Lingyun et al. (2009) Scan equalization digital radiography (SEDR) implemented with an amorphous selenium flat-panel detector: initial experience. Phys Med Biol 54:6959-78
Lai, Chao-Jen; Chen, Lingyun; Zhang, Huojun et al. (2009) Reduction in x-ray scatter and radiation dose for volume-of-interest (VOI) cone-beam breast CT--a phantom study. Phys Med Biol 54:6691-709
Chen, Lingyun; Shen, Youtao; Lai, Chao-Jen et al. (2009) Dual resolution cone beam breast CT: a feasibility study. Med Phys 36:4007-14