Mammography remains an important diagnostic tool for breast cancer screening and diagnosis and has helped save thousands of lives. However, not every woman who gets routine screening is saved by mammography and an unacceptably large number of women are subjected unnecessary testing, biopsy and treatment due to false positives. Fischer Imaging has partnered with Johns Hopkins University to develop MammoCAT CT, a device for improved mammography in a comfortable, prone configuration where the breast is held without compression and will perform full field, computed tomography (CT) imaging at the same dose as standard full field digital mammography. This device will use slot-scanning CT technology (SSCT) that permits highly flexible sparse data acquisitions for reduced scan time and reduced x-ray exposure. To aid this effort we propose using novel reconstruction algorithms based on compressed sensing theory have achieved sparse data reductions of an order of magnitude or more. This combination of innovation in both hardware and software will help MammoCAT CT improve the sensitivity and specificity of mammography by improving image resolution and contrast and removing image artifacts due to tissue superimposition, all using similar x-ray dose as that of standard mammography. An important advantage of the prone configuration in MammoCAT CT is that it will allow precision biopsy and therapy by using the same high performance image feedback as mammography in a prone, comfortable setting. We believe MammoCAT CT will usher in a new era where every woman will benefit from mammography and where tumors can be detected, diagnosed and biopsied in the same device thus improving equipment and space utilization and improving hospital workflow.

Public Health Relevance

Fischer Imaging?s proposed MammoCAT CT will improve breast cancer screening, diagnosis and biopsy by finding missed cancers, reducing unnecessary treatment, improving patient experience and the accuracy of biopsy. The device will additionally allow comprehensive patient care by allowing breast cancer screening, diagnosis and biopsy using the same device thus removing the need for multiple devices and multiple scheduling and/or transfer from one facility to another.

Agency
National Institute of Health (NIH)
Institute
National Cancer Institute (NCI)
Type
Small Business Innovation Research Grants (SBIR) - Phase I (R43)
Project #
1R43CA239777-01
Application #
9772685
Study Section
Special Emphasis Panel (ZRG1)
Program Officer
Narayanan, Deepa
Project Start
2019-04-01
Project End
2020-03-31
Budget Start
2019-04-01
Budget End
2020-03-31
Support Year
1
Fiscal Year
2019
Total Cost
Indirect Cost
Name
Fischer Imaging, Inc.
Department
Type
DUNS #
080473449
City
Wheat Ridge
State
CO
Country
United States
Zip Code
80033