Currently available continuous glucose sensors are inaccurate and prone to failure, making the goal of an artificial pancreas elusive. Furthermore, their designs are not patient-friendly and they require frequent user input (e.g. calibration). The largest hurdle in developing implantable glucose sensors is the foreign body response (FBR). In this Phase I SBIR, we propose a syringe-injectable, tissue-integrating, glucose sensor to mitigate the foreign body response and enable accurate glucose monitoring for a minimum of 3 weeks in the body. PROFUSA's long- term goal is to develop a self-calibrating, implantable CGM with a minimum operational life of 3 months and a longer-term goal of 12 months that will be sufficiently accurate so as to enable an artificial pancreas. Tiny, soft and porous tissue-integrating biosensors that encourage capillaries to grow in and throughout the entire cross section of the sensor are being developed to allow reliable sensor function and thus overcome limitations of the FBR. Prototype sensors will be produced by integrating luminescent sensing nanospheres (glucose-responsive and reference nanospheres) into previously developed vascularizing hydrogel scaffolds (developed by PROFUSA and collaborators through currently active grants). The near infrared sensor signals are read through the skin with a miniaturized Continuous Optical INterrogation (COIN) patch reader that utilizes novel micro-optics to significantly decrease background noise. The goal of this Phase I SBIR is to demonstrate in vivo sensor functionality with the sensor and reader prototypes. Advancements towards a thin-film patch reader that will continuously and discretely monitor blood glucose will improve patient compliance. Clinical translation of this technology will motivate and enable diabetic patients to more tightly control their glucose levels without fear of hypoglycemia, and will reduce the diabetes disease burden on the healthcare system.

Public Health Relevance

Diabetes is a devastating and costly chronic disease affecting nearly 25 million people in the US alone and amounting to $200B in annual healthcare expenditures. Upon successful proof-of- concept demonstration of our novel sensing approach in this SBIR Phase I, PROFUSA is poised to develop and commercialize a self-calibrating, implantable continuous glucose monitor (CGM) that will be embraced by patients and will enable an artificial pancreas. Adoption of the PROFUSA CGM will motivate and enable diabetic patients to more tightly control their glucose levels without fear of severe glucose lows, and will reduce the diabetes disease burden on the healthcare system.

Agency
National Institute of Health (NIH)
Institute
National Institute of Diabetes and Digestive and Kidney Diseases (NIDDK)
Type
Small Business Innovation Research Grants (SBIR) - Phase I (R43)
Project #
1R43DK093139-01
Application #
8196001
Study Section
Special Emphasis Panel (ZDK1-GRB-G (M3))
Program Officer
Arreaza-Rubin, Guillermo
Project Start
2011-09-15
Project End
2013-08-31
Budget Start
2011-09-15
Budget End
2012-08-31
Support Year
1
Fiscal Year
2011
Total Cost
$499,861
Indirect Cost
Name
Profusa, Inc.
Department
Type
DUNS #
830219338
City
San Francisco
State
CA
Country
United States
Zip Code
94107
Wisniewski, Natalie A; Nichols, Scott P; Gamsey, Soya J et al. (2017) Tissue-Integrating Oxygen Sensors: Continuous Tracking of Tissue Hypoxia. Adv Exp Med Biol 977:377-383
Ritter, Dustin W; Newton, Jared M; Roberts, Jason R et al. (2016) Albuminated Glycoenzymes: Enzyme Stabilization through Orthogonal Attachment of a Single-Layered Protein Shell around a Central Glycoenzyme Core. Bioconjug Chem 27:1285-92
Montero-Baker, Miguel F; Au-Yeung, Kit Yee; Wisniewski, Natalie A et al. (2015) The First-in-Man ""Si Se Puede"" Study for the use of micro-oxygen sensors (MOXYs) to determine dynamic relative oxygen indices in the feet of patients with limb-threatening ischemia during endovascular therapy. J Vasc Surg 61:1501-9.e1
Unruh, Rachel M; Roberts, Jason R; Nichols, Scott P et al. (2015) Preclinical Evaluation of Poly(HEMA-co-acrylamide) Hydrogels Encapsulating Glucose Oxidase and Palladium Benzoporphyrin as Fully Implantable Glucose Sensors. J Diabetes Sci Technol 9:985-92
Roberts, Jason R; Ritter, Dustin W; McShane, Michael J (2013) A Design Full of Holes: Functional Nanofilm-Coated Microdomains in Alginate Hydrogels. J Mater Chem B 107:3195-3201
Ritter, Dustin W; Roberts, Jason R; McShane, Michael J (2013) Glycosylation site-targeted PEGylation of glucose oxidase retains native enzymatic activity. Enzyme Microb Technol 52:279-85
Roberts, Jason R; Park, Jaebum; Helton, Kristen et al. (2012) Biofouling of polymer hydrogel materials and its effect on diffusion and enzyme-based luminescent glucose sensor functional characteristics. J Diabetes Sci Technol 6:1267-75