This Lab to Marketplace SBIR Phase I Phase II Fast Track Application has as its long- term objective to establish ultrasound as a safe, effective, and non-invasive method for assessing fracture risk, an important component in clinical management of osteoporosis. Osteoporosis afflicts over 20 million people in the U.S., and is responsible for more than 275,000 hip fractures annually. Currently, the primary means for assessment relies on densitometric techniques. These methods subject the patient to ionizing radiation, are relatively expensive, and do not always provide good estimates of bone strength. Ultrasound offers several potential advantages. It is non- ionizing and relatively inexpensive. Moreover, since ultrasound is a mechanical wave and interacts with bone in a fundamentally different manner than electromagnetic radiation, it may ultimately be able to provide more accurate estimates of bone strength and fracture risk compared with current densitometric methods. The goal of this research is to develop a new ultrasound system for bone assessment that is not only accurate but also highly reproducible. The system will assess the heel bone (calcaneus) distal forearm employ a novel positioning device that is foot-size based. The technology is designed to achieve both high reproducibility, as well as analogous regions of interest among different individuals to be compared. This is crucial given the high degree of heterogeneity that exists in the calcaneus. This research should enable the widespread detection of osteoporosis and fracture risk, and will find application not only in the U.S. but worldwide as well.
The specific aims of this Lab to Marketplace Fast Track SBIR Application are to demonstrate the feasibility of a novel positioning device which in conjunction with CyberLogic's NTD technology to accurately and reproducibly estimate BMD at the calcaneus. This will be achieved by clinical testing in Phase I using a laboratory prototype that incorporates the patented positioning technology. This will if successful, be followed by fabrication of a clinical device in the first year of Phase II, followed by 24 months of extensive Phase II clinical testing, which will include comparison of ultrasound data in subjects with and without fragility fractures. Finally, the last year of Phase II will include submission to FDA of a 510(k) application. The ultimate goal of this research is to commercialize this novel heel ultrasound device and to bring it into worldwide use for a simple, safe and effective instrument for bone density estimation and fracture risk assessment.

Public Health Relevance

As stated by the National Osteoporosis Foundation, osteoporosis is a major public health threat for an estimated 44 million Americans, or 55 percent of the people 50 years of age and older. In the U.S., 20 million individuals are estimated to already have the disease and almost 34 million more are estimated to have low bone mass, placing them at increased risk for osteoporosis. While osteoporosis is often thought of as an older person's disease, it can strike at any age. Osteoporosis is responsible for more than 1.5 million fractures annually, including over 300,000 hip fractures and approximately 700,000 vertebral fractures and 250,000 wrist fractures. Notwithstanding these facts, osteoporosis is under-recognized and under-treated. The proposed research should enable bone testing to be done conveniently and safely in a primary care setting. This should lead to earlier detection and treatment and ultimately to reductions in the number of fractures.

Agency
National Institute of Health (NIH)
Institute
National Institute of Arthritis and Musculoskeletal and Skin Diseases (NIAMS)
Type
Small Business Innovation Research Grants (SBIR) - Phase II (R44)
Project #
5R44AR064113-04
Application #
9127088
Study Section
Special Emphasis Panel (ZRG1)
Program Officer
Wang, Xibin
Project Start
2014-09-01
Project End
2017-08-31
Budget Start
2016-09-01
Budget End
2017-08-31
Support Year
4
Fiscal Year
2016
Total Cost
Indirect Cost
Name
Cyberlogic, Inc.
Department
Type
DUNS #
861097715
City
New York
State
NY
Country
United States
Zip Code
10012
Stein, Emily M; Rosete, Fernando; Young, Polly et al. (2013) Clinical assessment of the 1/3 radius using a new desktop ultrasonic bone densitometer. Ultrasound Med Biol 39:388-95