The mission of TibaRay, Inc. is to develop and clinically translate next-generation radiation therapy technologies for the treatment of cancer, the single leading cause of death worldwide and increasing epidemically. A major advance in radiation therapy (RT) that has increased its curative potential and decreased side effects is the ability to sculpt radiation doses exquisitely in 3D to conform to tumors and spare surrounding healthy organs. This is achieved by delivering radiation beams to the tumor from multiple directions, each of which has an optimized spatial intensity distribution. However, the fastest treatment times are still minutes long, limited by both beam intensities in electron linacs and the mechanical systems that are used to direct and shape the beams. Recently, ultra-fast (<1s) high dose rate (300X) FLASH-RT has proven in pre-clinical studies to have high therapeutic index. But there is no existing technology to enable this therapy in the clinical, photon-based setting. To address these major shortcomings of current state-of-the-art radiation delivery systems, TibaRay has proposed a radical new design for RT systems, Pluridirectional High-energy Agile Scanning Electronic Radiotherapy (PHASER). It is based on patented, novel technologies to produce intensity-modulated therapeutic energy x-ray beams from multiple directions using no mechanical systems to direct (i.e. no rotating gantry) or shape the treatment beams (i.e. no mulit-leaf collimator). This is achieved by using an array of novel electron linacs each of which uses a magnetic electron beam scanning scheme paired with an extended bremsstrahlung target and multi-channel collimator array system referred to as Scanning Pencil-array-collimated High Speed Intensity-modulated X-ray source (SPHINX). Each of the novel linacs used in PHASER are far more efficient and will generate more beam than conventional medical linacs. In the full PHASER design, it is estimated that the treatment time can be reduced to <1s, effectively freezing physiological motion. The novel accelerator technology uses much simpler manufacturing techniques and production costs for PHASER are projected to be about the same as current state-of-the-art systems and maintenance/downtime costs should be lower. Initial proof of principle for the subsystems needed for PHASER have been demonstrated and design simulations have been performed in Phase 1. In Phase II, TibaRay, in partnership with the Stanford University Department of Radiation Oncology will optimize, build and test at first a single complete beam line with full maximum power. Then we will build and test a two-beam PHASER prototype to demonstrate the full rapid RF switching capability. These tests will be used to de-risk the primary working components of the system and will enable swift progress towards commercialization and clinical translation. Our novel technology will help fill a tremendous worldwide need for high-quality, cost-effective radiation therapy for cancer.

Public Health Relevance

The goal of the proposal is to design a two-beam version of our Pluridirectional High-energy Agile Scanning Electronic Radiotherapy (PHASER) concept to improve the accuracy, precision, speed, and cost-effectiveness of radiation therapy for cancer. PHASER will enable the generation of high-resolution intensity-modulated radiation beams for rapid and exquisite 3-D radiation dose sculpting through all-electronic beam control, replacing the current state-of-the-art beam shaping through highly complex and failure-prone mechanical devices. PHASER enables treatment delivery fast enough to freeze the motion of moving tumors and will lead to more effective radiation treatments for cancer using methods such as FLASH.

Agency
National Institute of Health (NIH)
Institute
National Cancer Institute (NCI)
Type
Small Business Innovation Research Grants (SBIR) - Phase II (R44)
Project #
5R44CA217607-04
Application #
10020908
Study Section
Special Emphasis Panel (ZRG1)
Program Officer
Canaria, Christie A
Project Start
2017-03-17
Project End
2022-08-31
Budget Start
2020-09-01
Budget End
2021-08-31
Support Year
4
Fiscal Year
2020
Total Cost
Indirect Cost
Name
Tibaray, Inc.
Department
Type
DUNS #
079645501
City
Sunnyvale
State
CA
Country
United States
Zip Code
94089