Physical Optics Corporation (POC) proposes to develop and fabricate a new retina-Tracking Adaptive-optic Scanning Laser Ophthalmoscope (TASLO) system based on high-resolution adaptive optics aberration correction by means of a microelectromechanical system (MEMS) deformable mirror and a Shack-Hartmann wavefront sensor, with fast retina tracking by means of optoelectronic joint Fourier transform correlation. TASLO's high-speed tracking and high-resolution imaging capability will overcome the limitations of current systems imposed by eye aberrations and eye movement. The goal of this Phase II project is to develop a complete engineering TASLO prototype ready for testing and validation in research laboratories and in a clinical environment. The novel TASLO design, based on the Phase I feasibility demonstration, will produce a robust, compact, and simple-to-use system for extremely fast, noninvasive in situ and in vivo tomographic imaging of the retina with high resolution and contrast, as well as image stabilization. The TASLO device can contribute to early diagnosis of macular degeneration and other degenerative vascular diseases of the retina and choroids, which is crucial to the prevention of blindness and for general eye health care.

Public Health Relevance

The proposed retina-Tracking Adaptive-optic Scanning Laser Ophthalmoscope (TASLO) system offers a simple optical design and is based on commercially available electro-optical components to integrate the adaptive-optic (AO) aberration correction and joint Fourier transform correlation (JFTC) retina tracking with a state-of-the-art scanning laser ophthalmoscope. Current commercial ophthalmic imaging systems have low transverse resolution and little or no axial resolution, and they do not provide stable measurements due to uncontrollable involuntary patient's eye movements during the measurements. The proposed TASLO applies adaptive optics, optical correlation, and DSP technologies to improve reliability, transverse resolution (from 10

Agency
National Institute of Health (NIH)
Institute
National Eye Institute (NEI)
Type
Small Business Innovation Research Grants (SBIR) - Phase II (R44)
Project #
5R44EY015934-03
Application #
7935207
Study Section
Special Emphasis Panel (ZRG1-ETTN-E (12))
Program Officer
Wujek, Jerome R
Project Start
2004-07-01
Project End
2012-09-29
Budget Start
2010-09-30
Budget End
2012-09-29
Support Year
3
Fiscal Year
2010
Total Cost
$365,583
Indirect Cost
Name
Physical Optics Corporation
Department
Type
DUNS #
153865951
City
Torrance
State
CA
Country
United States
Zip Code
90501