The ideal biological imaging system would provide non-invasive, high-resolution, high-sensitivity, three-dimensional (3D) functional and anatomic images of living systems. Positron Emission Tomography (PET) offers high sensitivity to a range of biological processes through the use of targeted radiolabeled probes. Unfortunately, precise signal localization can be extremely difficult due to low spatial resolution and the lack of anatomical information in PET. Magnetic Resonance Imaging (MRI) can provide high spatial resolution and excellent soft tissue contrast, but suffers from poor signal strength leading to low sensitivity. The overall goal of the proposed effort is to combine the best features of PET and MR modalities for small animal studies into a single imaging instrument that will record data in both imaging modalities simultaneously. The most immediate benefit of the integrated system will be to provide high-resolution anatomical context for PET studies. This will lead to better overall understanding of the origin of the PET signals. The 'in-register' MR images may be used to compute scatter and attenuation in the PET images and also to estimate partial volume errors in the lower-resolution PET scans, thus aiding quantification of the PET signal. The integrated system will open up a number of opportunities not possible with current independent PET and MRI scanners. ? ? ?

Agency
National Institute of Health (NIH)
Institute
National Institute of Neurological Disorders and Stroke (NINDS)
Type
Small Business Innovation Research Grants (SBIR) - Phase II (R44)
Project #
2R44NS055377-02
Application #
7326385
Study Section
Special Emphasis Panel (ZRG1-SBIB-Q (50))
Program Officer
Chen, Daofen
Project Start
2006-07-03
Project End
2009-07-31
Budget Start
2007-08-01
Budget End
2008-07-31
Support Year
2
Fiscal Year
2007
Total Cost
$522,226
Indirect Cost
Name
Radiation Monitoring Devices, Inc.
Department
Type
DUNS #
073804411
City
Watertown
State
MA
Country
United States
Zip Code
02472
St James, Sara; Yang, Yongfeng; Bowen, Spencer L et al. (2010) Simulation study of spatial resolution and sensitivity for the tapered depth of interaction PET detectors for small animal imaging. Phys Med Biol 55:N63-74
Wu, Yibao; Ng, Thomas S C; Yang, Yongfeng et al. (2009) A study of the timing properties of position-sensitive avalanche photodiodes. Phys Med Biol 54:5155-72
Wu, Yibao; Catana, Ciprian; Farrell, Richard et al. (2009) PET Performance Evaluation of an MR-Compatible PET Insert. IEEE Trans Nucl Sci 56:574-580
James, Sara St; Yang, Yongfeng; Wu, Yibao et al. (2009) Experimental characterization and system simulations of depth of interaction PET detectors using 0.5 mm and 0.7 mm LSO arrays. Phys Med Biol 54:4605-19