? ? The Prospective Investigation of Pulmonary Embolism Diagnosis III (PIOPED III) is a multicenter prospective investigation designed to determine the diagnostic accuracy of gadolinium enhanced magnetic resonance angiography of the pulmonary arteries (Gd-MRA) in combination with magnetic resonance venography of the veins of the thighs (MRV) in patients with clinically suspected acute pulmonary embolism (PE). This is the proposal for the Massachusetts General Hospital The diagnostic accuracy of Gd-MRA alone and in combination with MRV will be expressed as sensitivity, specificity, and likelihood ratio for positive and negative tests. The study design is a prospective study of consecutive patients incorporating standardized inclusion/exclusion criteria, complete ascertainment of patient characteristics and outcomes, uniform diagnostic criteria, and unbiased paired central readings of imaging studies. Over a period of two years, 1256 patients with suspected acute PE will be recruited at 7 clinical centers. Composite reference standards will be used to diagnose VTE and exclude PE. It is expected that 314 patients will have acute VTE and they will undergo Gd-MRA/MRV. It is expected that 942 patients will be shown not to have PE. From among this group, 314 patients will be randomly selected for the index test, Gd-MRA/MRV. The strengths of this proposal are: 1) the importance of the problem of PE in terms of lives lost from underdiagnosis and major bleeding from overdiagnosis, 2) the potential aplicability of a new technology for the diagnosis ofPE, 3) a strong investigative team that has collaborated previously in successful reaearch in PE, 4) a protocol tha parallels previously proven protocols for the evaluation of a diagnostic test for PE. The Massachusetts General Hospital adds to the strength of PIOPED III by showing that Gd-MRA/MRV can be used successful!} for the diiagnosis of VTE in a tertiary care hospital. ? ?

Agency
National Institute of Health (NIH)
Institute
National Heart, Lung, and Blood Institute (NHLBI)
Type
Research Project--Cooperative Agreements (U01)
Project #
5U01HL077149-04
Application #
7499724
Study Section
Special Emphasis Panel (ZHL1-CSR-C (M3))
Program Officer
Moore, Timothy M
Project Start
2005-08-01
Project End
2010-05-31
Budget Start
2008-06-01
Budget End
2010-05-31
Support Year
4
Fiscal Year
2008
Total Cost
$399,897
Indirect Cost
Name
Massachusetts General Hospital
Department
Type
DUNS #
073130411
City
Boston
State
MA
Country
United States
Zip Code
02199
Woodard, Pamela K; Chenevert, Thomas L; Sostman, H Dirk et al. (2012) Signal quality of single dose gadobenate dimeglumine pulmonary MRA examinations exceeds quality of MRA performed with double dose gadopentetate dimeglumine. Int J Cardiovasc Imaging 28:295-301
Sostman, H Dirk; Jablonski, Kathleen A; Woodard, Pamela K et al. (2012) Factors in the technical quality of gadolinium enhanced magnetic resonance angiography for pulmonary embolism in PIOPED III. Int J Cardiovasc Imaging 28:303-12
Stein, Paul D; Chenevert, Thomas L; Fowler, Sarah E et al. (2010) Gadolinium-enhanced magnetic resonance angiography for pulmonary embolism: a multicenter prospective study (PIOPED III). Ann Intern Med 152:434-43, W142-3
Stein, Paul D; Gottschalk, Alexander; Sostman, H Dirk et al. (2008) Methods of Prospective Investigation of Pulmonary Embolism Diagnosis III (PIOPED III). Semin Nucl Med 38:462-70