Symptomatic adult and pediatric structural heart disease affects more than 2.9% of the US population, not including cardiomyopathies and rhythm disorders. Although nonsurgical approach is the preferred route for relief of symptoms, even common procedures such as atrial septal defect closure can be difficult, protracted, or unsuccessful because of limitations not only in available catheter devices but also because of inadequate image guidance. Current 2D and limited-volume 3D intracardiac ultrasound catheters do not provide suitable full-volume en face images to depict complex cardiac structures in real time, do not depict real-time navigation of catheters, and require adjunctive X-ray guidance. Miniaturization of ultrasound probes to provide uninterrupted real-time full-volume intra-procedural 3-dimensional en-face depiction of cardiac pathology and catheter devices would represent a dramatic advance in image-guided intervention. Further, design of a 3D ICE probe from inception to operate safely during MRI as well as during conventional X-ray would dramatically advance or even revolutionize the capabilities of transcatheter therapy by enabling completely radiation-free non-surgical catheter navigation. Our proposal aims to realize such a catheter, the 3D MRICE, based on the close collaboration of two groups at NHLBI and at Georgia Tech, and the unique resources available at the NIH Clinical Center for catheter fabrication, preclinical evaluation, and clinical trials. We use CMUT-on-CMOS technology and massive parallel RF data multiplexing to implement an ultra- miniature, single chip volumetric ultrasound imaging system while reducing the transmission line count by 50x compared with current technology. Implemented as a novel actively cooled catheter of MRI-compatible materials, our approach will produce a versatile intravascular 3D ICE catheter that can operate under conventional X-ray and MRI. The 3D MRICE and custom, GPU based real-time imaging system will be evaluated systematically through in-vitro and in-vivo studies with special emphasis on MRI safety leading to a an Phase I IDE clinical trial at the end of year 3. If successful, our work will address a key unmet need and fundamentally enhance image-guided catheter treatments of complex heart disease to improve effectiveness and outcome.

Public Health Relevance

Many transcatheter procedures used for treatment of structural heart diseases are demanding and protracted. Success and complications can be improved by adequate image guidance. Our partnership of clinicians and engineers is planning to develop a new catheter based ultrasound system which can also be used under MRI to image inside the heart to reduce the duration of complex procedures, minimizing radiation exposure to the patient and improving the results.

Agency
National Institute of Health (NIH)
Institute
National Heart, Lung, and Blood Institute (NHLBI)
Type
Research Project--Cooperative Agreements (U01)
Project #
5U01HL121838-02
Application #
8803405
Study Section
Special Emphasis Panel (ZHL1-CSR-S (O1))
Program Officer
Olive, Michelle
Project Start
2014-02-07
Project End
2017-01-31
Budget Start
2015-02-01
Budget End
2016-01-31
Support Year
2
Fiscal Year
2015
Total Cost
$636,803
Indirect Cost
$216,374
Name
Georgia Institute of Technology
Department
Engineering (All Types)
Type
Schools of Engineering
DUNS #
097394084
City
Atlanta
State
GA
Country
United States
Zip Code
30332
Pirouz, Amirabbas; Degertekin, F Levent (2018) Low Temperature CMUT Fabrication Process with Dielectric Lift-off Membrane Support for Improved Reliability. J Micromech Microeng 28:
Jung, Gwangrok; Tekes, Coskun; Pirouz, Amirabbas et al. (2018) Supply-Doubled Pulse-Shaping High Voltage Pulser for CMUT Arrays. IEEE Trans Circuits Syst II Express Briefs 65:306-310
Shieh, Bernard; Sabra, Karim G; Degertekin, F Levent (2018) A Hybrid Boundary Element Model for Simulation and Optimization of Large Piezoelectric Micromachined Ultrasonic Transducer Arrays. IEEE Trans Ultrason Ferroelectr Freq Control 65:50-59
Lim, Jaemyung; Tekes, Coskun; Degertekin, F Levent et al. (2017) Towards a Reduced-Wire Interface for CMUT-Based Intravascular Ultrasound Imaging Systems. IEEE Trans Biomed Circuits Syst 11:400-410
Adams, Chris; Harput, Sevan; Cowell, David et al. (2017) An Adaptive Array Excitation Scheme for the Unidirectional Enhancement of Guided Waves. IEEE Trans Ultrason Ferroelectr Freq Control 64:441-451
Shieh, Bernard; Sabra, Karim G; Degertekin, F Levent (2016) Efficient Broadband Simulation of Fluid-Structure Coupling for Membrane-Type Acoustic Transducer Arrays Using the Multilevel Fast Multipole Algorithm. IEEE Trans Ultrason Ferroelectr Freq Control 63:1967-1979
Shieh, Bernard; Sabra, Karim; Degertekin, Levent (2016) Efficient broadband simulation of fluid-structure coupling for membrane-type acoustic transducer arrays using the multi-level fast multipole algorithm. IEEE Trans Ultrason Ferroelectr Freq Control :
Carpenter, Thomas M; Rashid, M Wasequr; Ghovanloo, Maysam et al. (2016) Direct Digital Demultiplexing of Analog TDM Signals for Cable Reduction in Ultrasound Imaging Catheters. IEEE Trans Ultrason Ferroelectr Freq Control 63:1078-85
Satir, Sarp; Degertekin, F Levent (2015) A nonlinear lumped model for ultrasound systems using CMUT arrays. IEEE Trans Ultrason Ferroelectr Freq Control 62:1865-79
Xu, Toby; Tekes, Coskun; Degertekin, F (2014) CMUTs with high-K atomic layer deposition dielectric material insulation layer. IEEE Trans Ultrason Ferroelectr Freq Control 61:2121-31