The Ischemic Optic Neuropathy Decompression Trial (IONDT) is a three year study designed to assess the safety and efficacy of optic nerve sheath decompression surgery (ONDS) for non-arteritic ischemic optic neuropathy, diagnosed within one month of onset of visual symptoms. A standardized, common protocol for treatment and data collection will be used by all centers. This multicenter, randomized clinical trial is designed to compare differences in patients randomized to one of two treatment groups as follows: Treatment Group Treatment Sequences Patients 1. Test Treatment Optic Nerve Sheath 150 Decompression Surgery 2. Control Treatment Standard Medical Care 150 (No Surgery) The primary hypotheses to be addressed by this trial are: Is treatment with ONDS more effective than standard care in 1) restoring or 2) maintaining central visual acuity in patients with NAION? The primary outcome for this trial (change in visual acuity) will be measured using the New York Lighthouse chart. A gain of three or more lines of visual acuity (doubling of the visual angle) will be considered improvement. Secondary outcomes include: change in peripheral visual function (using standard Automated perimetry); and incidence of ophthalmic and systemic complications. Patients will be recruited over a two year period and followed for a minimum of one year. Study centers will include a Chairman's Center, 27 clinical centers, and centralized facilities, including a Coordinating Center, a reading center and a project office at the National Eye Institute.

Agency
National Institute of Health (NIH)
Institute
National Eye Institute (NEI)
Type
Cooperative Clinical Research--Cooperative Agreements (U10)
Project #
5U10EY009584-03
Application #
2387185
Study Section
Vision Research and Training Committee (VSN)
Project Start
1992-06-15
Project End
2000-11-30
Budget Start
1996-12-01
Budget End
1997-11-30
Support Year
3
Fiscal Year
1997
Total Cost
Indirect Cost
Name
University of Missouri-Columbia
Department
Ophthalmology
Type
Schools of Medicine
DUNS #
112205955
City
Columbia
State
MO
Country
United States
Zip Code
65211
Scherer, Roberta W; Feldon, Steven E; Levin, Lori et al. (2008) Visual fields at follow-up in the Ischemic Optic Neuropathy Decompression Trial: evaluation of change in pattern defect and severity over time. Ophthalmology 115:1809-17
Newman, Nancy J (2007) The ischemic optic neuropathy decompression trial. Arch Ophthalmol 125:1568-70
Feldon, Steven E; Levin, Lori; Scherer, Roberta W et al. (2006) Development and validation of a computerized expert system for evaluation of automated visual fields from the Ischemic Optic Neuropathy Decompression Trial. BMC Ophthalmol 6:34
Feldon, Steven E; Scherer, Roberta W; Hooper, Frank J et al. (2003) Surgical quality assurance in the Ischemic Optic Neuropathy Decompression Trial (IONDT). Control Clin Trials 24:294-305
Scherer, Roberta; Zhu, Qi; Langenberg, Patricia et al. (2003) Comparison of information obtained by operative note abstraction with that recorded on a standardized data collection form. Surgery 133:324-30
Newman, Nancy J; Scherer, Roberta; Langenberg, Patricia et al. (2002) The fellow eye in NAION: report from the ischemic optic neuropathy decompression trial follow-up study. Am J Ophthalmol 134:317-28