High-pressure liquid chromatography (HPLC) and subsequent analysis by mass spectrometry (MS) are important, gold-standard techniques in the field of proteomics. This approach has been further enhanced by the introduction of microflow HPLC coupled directly to nanospray MS inlets. Although this can greatly save on sample materials, many peaks that are resolvable with MS are below the current limit of detection for standard or micro UV HPLC detectors. The use of fluorescence detection, which has substantially greater sensitivity, allows on-line, continuous monitoring of the HPLC effluent prior to MS analysis in these micro and nanoflow systems. The coupling of fluorescence detection with MS analysis then allows for multi-dimensional analysis of the sample under investigation: with internal standards, each resolved peak can be quantified prior to MS characterization. To accomplish this advance in MS technology, a miniature in-line microfluidic laser induced fluorescence (LIF) detector was designed and constructed. The key feature of this detector is its portability, which permits easy insertion into the capillary microfluidic flow path after HPLC separation and immediately prior to MS analysis. This is enabled by the use of fiber-optics for both the excitation and emission paths of the laser induced fluorescence detector that allows bulky light sources, optical filtration elements, and photon detectors to be housed remotely from the point of detection. ? ? The small (4x4x1cm) prototype detector head consists of an embedded channel to accommodate a short length of silica capillary, with a 385-micron outside diameter and a square 100-micron diameter internal flow path. Perpendicular to the capillary is a second embedded channel to accommodate a 200-micron fused silica optical fiber that is positioned in close proximity to an observation window formed in the capillary by removal of approximately 2 mm of the polyimide coating. This fiber conducts excitation light (405 nm in this instance) to induce fluorescence of the sample analytes that are tagged with naphthalene dicarboxaldehyde (NDA). ? ? A second optical fiber, 600-micron fused silica, is also positioned at the same observation point and is perpendicular to both the capillary and the excitation fiber. The light collected by this optical fiber is passed through a thin-film filter to eliminate scattered laser light, and the remaining fluorescent signal is detected using a photomultiplier tube. The signal from the photomultiplier tube can be read by any voltage recorder, digital or analog. The complete detector head, including capillary tubing, interconnects and a light-tight housing is approximately 10 cm in length and 5 cm in cross section.? ? The observation sample volume is approximately 6 nl and a sensitivity of 50 fmol or less was achieved by LIF with NDA peptide labelling of a tryptic digest of apomyoglobin that was used as a model sample for proteomic analysis. Chromatograms show excellent resolution at flow rates of 5 microliters/min. The sensitivity and resolution achieved place this detector at the current state-of the-art, which together with its compactness and portability make it a significant advance in HPLC/MS technology. ? ? This year, we incorporated a second laser and detection channel into the detector, using a pulsed 266 nm laser for excitation of native tryptophan fluorescence in peptides, without increasing the size of the detector head. The UV laser required the use of different excitation and detection fibers, in order to avoid extremely high background fluorescence from the fiber cladding. In addition, we incorporated a high-NA Teflon clad silica fiber for detection in order to increase the detected signal. Even so, the detection limit for tryptophan was somewhat higher than that of the NDA labeled peptides, primarily because of higher background fluorescence. In addition, we worked on making a similar detector for use within DBEPS, but with lasers at 405 and 660 nm, to be used with double-labeled samples.

Agency
National Institute of Health (NIH)
Institute
Office of The Director, National Institutes of Health (OD)
Type
Intramural Research (Z01)
Project #
1Z01OD022009-02
Application #
7319257
Study Section
(BEPS)
Project Start
Project End
Budget Start
Budget End
Support Year
2
Fiscal Year
2006
Total Cost
Indirect Cost
Name
Office of the Director, NIH
Department
Type
DUNS #
City
State
Country
United States
Zip Code