The objective of this contract is to perform research leading to the development of a miniature tether-free electromechanically actuated implantable cardiac replacement system. An implantable cardiac replacement system as defined here includes biventricular support which assist the right and left ventricles which remain in situ and the total artificial heart which replaces the excised natural heart. The implantable subsystems of the replacement system include right and left heart blood pumps, and electromechanical energy converter(s), appropriate control systems, and implantable battery pack to provide short-term energy source for the system, a variable volume device and a mechanism for delivering electrical energy for outside to inside the body. The external battery pack will include electrochemical batteries, charging circuitry, and system monitor/diagnostic circuitry.

Agency
National Institute of Health (NIH)
Institute
Division of Heart And Vascular Diseases (NHLBI)
Type
Research and Development Contracts (N01)
Project #
N01HV088105-001
Application #
3662268
Study Section
Project Start
1988-01-01
Project End
1993-09-30
Budget Start
1988-09-09
Budget End
1989-09-30
Support Year
Fiscal Year
1988
Total Cost
Indirect Cost
Name
Pennsylvania State University
Department
Type
Schools of Medicine
DUNS #
129348186
City
Hershey
State
PA
Country
United States
Zip Code
17033
Hoang, Q T; Hete, B F; Gaumond, R P (1993) Comments on ""Radio-frequency coils in implantable devices: misalignment analysis and design procedure"". IEEE Trans Biomed Eng 40:715
Snyder, A J; Rosenberg, G; Weiss, W J et al. (1993) In vivo testing of a completely implanted total artificial heart system. ASAIO J 39:M177-84
Baldwin, J T; Deutsch, S; Petrie, H L et al. (1993) Determination of principal reynolds stresses in pulsatile flows after elliptical filtering of discrete velocity measurements. J Biomech Eng 115:396-403
al-Mondhiry, H; Pae, W E; Miller, C A et al. (1992) Platelet and fibrinogen survival in calves implanted with artificial heart and ventricular assist device--correlation with autopsy findings. Thromb Haemost 67:413-6
Baldwin, J T; Tarbell, J M; Deutsch, S et al. (1991) Mean velocities and Reynolds stresses within regurgitant jets produced by tilting disc valves. ASAIO Trans 37:M348-9
Pierce, W S; Rosenberg, G; Snyder, A J et al. (1990) An electric artificial heart for clinical use. Ann Surg 212:339-43;discussion 343-4
Baldwin, J T; Deutsch, S; Geselowitz, D B et al. (1990) Estimation of Reynolds stresses within the Penn State left ventricular assist device. ASAIO Trans 36:M274-8
Weiss, W J; Rosenberg, G; Snyder, A J et al. (1990) Permanent circulatory support systems at the Pennsylvania State University. IEEE Trans Biomed Eng 37:138-45
Baldwin, J T; Tarbell, J M; Deutsch, S et al. (1989) Mean flow velocity patterns within a ventricular assist device. ASAIO Trans 35:429-33