Approximately half of the two million infections acquired at hospitals in the US are associated with implanted medical devices. Bacterial colonization of implanted medical device surfaces is a major cause of device failure and usually requires device removal coupled with long term antibiotic treatment. Risks of morbidity/mortality from surgery and prolonged hospitalization make early detection critical. However, detection is challenging at early stages prior to development of systemic symptoms of infection when bacteria localized to inaccessible regions of the implant. We will develop a novel medical imaging technique, X-ray excited luminescent chemical imaging (XELCI) to non-invasively detect and monitor bacterial biofilms on modified implant surfaces. Our long term goal is to develop a sensor to detect and monitor in vivo infection. The approach is innovative because no other imaging technique provides surface-specific chemical information at high-resolution through thick tissue. XELCI is a type of scanning optical microscopy wherein a narrow X-ray beam irradiates a radioluminescent film on the implant surface creating a local luminescent spot with pH -dependent spectra. Although the luminescence scatters and blurs as it passes through the tissue in the ?far field,? the spectrum depends upon the local pH at the luminescence source, and image resolution is defined by the X-ray beam width. We will apply the technique to detect acidosis beneath biofilms in order to detect and monitor infection. Our two specific aims are to 1) Refine and validate XELCI sensors in vitro and ex vivo; 2) Use XELCI to Assess pH Changes during Healing and Infection in a Rabbit Model. The proposed research is significant because it develops a non-invasive method to detect, monitor, and study biofilms in situ with the ultimate potential for reducing morbidity, mortality and associated cost from implant infections.

Public Health Relevance

This research project develops a novel technique for non-invasive imaging of pH on surfaces of modified implanted medical devices. The proposed research is relevant to public health because half of hospital acquired infections are associated with implanted medical devices and our technique will allow non-invasive monitoring of implant surfaces in order to detect infections, develop better antimicrobial surfaces, and monitor treatments. 1

Agency
National Institute of Health (NIH)
Institute
National Institute of Arthritis and Musculoskeletal and Skin Diseases (NIAMS)
Type
Research Project (R01)
Project #
5R01AR070305-02
Application #
9313185
Study Section
Bioengineering, Technology and Surgical Sciences Study Section (BTSS)
Program Officer
Washabaugh, Charles H
Project Start
2016-07-11
Project End
2021-06-30
Budget Start
2017-07-01
Budget End
2018-06-30
Support Year
2
Fiscal Year
2017
Total Cost
Indirect Cost
Name
Clemson University
Department
Chemistry
Type
Schools of Arts and Sciences
DUNS #
042629816
City
Clemson
State
SC
Country
United States
Zip Code
29634
Benza, Donald; Uzair, Unaiza; Raval, Yash et al. (2017) X-ray excited luminescent chemical imaging (XELCI) for non-invasive imaging of implant infections. Proc SPIE Int Soc Opt Eng 10081: