Patient motion is an ever-present potential cause of artifacts that can limit the accuracy of diagnostic imaging. The problem is especially significant for imaging modalities such as SPECT and PET, which require the patient to remain motionless for protracted periods of time, and multimodality imaging where patient alignment between the modalities is essential. Our hypothesis is that integrating into iterative reconstruction combined information from a visual-tracking-system (VTS) and the imaging modalities themselves will result in a robust motion-correction strategy. By VTS we mean a computational system that processes stereo-images of retro-reflective markers on the patient surface to provide a source of motion information that is independent of the clinical imaging system(s). The types of patient motion for which compensation will be investigated for cardiac perfusion SPECT imaging with this combined approach are rigid-body motion (RBM), non-rigid-body motion (non-RBM), respiratory motion (RM), cardiac upward creep (which is caused by changes in RM), and motion between sequential multi-modality imaging studies. Note we correct body-motion and RM differently, thus we differentiate between them as part of motion estimation. In this competitive renewal we propose to extend our current VTS to include application with multimodality imaging, emission data-consistency, and finite-element-modeling (FEM) based correction of non-RBM. MRI of volunteers will be employed to establish the relationship between external-marker motion and the motion of the heart within the body. MRI will also provide high-resolution anatomy of the chest at different motion states in combination with measured-marker motion to guide the creation of realistic SPECT simulations for refinement of algorithms. Initial clinical testing will make use of repeat-rest cardiac-SPECT studies in patient-volunteers where the first rest imaging study serves as the standard for judging the success of correction of the second study during which the patients intentionally move. The ultimate assessment of the success of our hypothesis will be physician-observer ROC studies comparing the detection accuracy of coronary artery disease (CAD) with and without motion compensation for patients undergoing SPECT perfusion imaging with the results of cardiac catheterization serving as the """"""""gold"""""""" standard. We believe the significance of our proposed investigations lies not only in the potential to improve diagnostic accuracy through motion-correction of both cardiac and non-cardiac SPECT, PET, and multimodality imaging but also in affording a better understanding of patient motion during imaging.

Public Health Relevance

Patients commonly move during the protracted imaging period required by SPECT and PET to collect a statistically sufficient number of events to form images for making an accurate diagnosis. Such motion can cause artifactual changes in the slices which may mislead the physician. In multi-modality imaging patients also may move between emission imaging and imaging used to form attenuation maps and provide an anatomical framework for the functional changes in emission imaging. This can cause a misregistration between the two sets of images which can significantly impact clinical interpretation. Also all images acquired while patients are breathing suffer from respiratory motion blurring of the structures being imaged. The goal of this project is to develop an accurate and robust motion-correction methodology for all forms of patient motion which minimally alters current acquisition protocols so that it can be employed in a busy clinic. The test-bed we have chosen for development of this methodology is cardiac perfusion SPECT imaging which is not only the single most frequent SPECT imaging procedure performed today, but also plays a critical role in providing perfusion and functional information needed for risk assessment and stratification regarding coronary artery disease. Once the methodology is perfected for cardiac SPECT it can be adapted for use with other SPECT and PET imaging procedures. The proposed research will also provide a better understanding of patient motion during medical imaging and treatment.

Agency
National Institute of Health (NIH)
Institute
National Institute of Biomedical Imaging and Bioengineering (NIBIB)
Type
Research Project (R01)
Project #
3R01EB001457-09S1
Application #
8685384
Study Section
Biomedical Imaging Technology Study Section (BMIT)
Program Officer
Sastre, Antonio
Project Start
2003-06-01
Project End
2014-03-31
Budget Start
2013-07-01
Budget End
2014-03-31
Support Year
9
Fiscal Year
2013
Total Cost
$90,686
Indirect Cost
$36,220
Name
University of Massachusetts Medical School Worcester
Department
Radiation-Diagnostic/Oncology
Type
Schools of Medicine
DUNS #
603847393
City
Worcester
State
MA
Country
United States
Zip Code
01655
Dasari, Paul K R; Könik, Arda; Pretorius, P Hendrik et al. (2017) Correction of hysteretic respiratory motion in SPECT myocardial perfusion imaging: Simulation and patient studies. Med Phys 44:437-450
Smyczynski, Mark S; Gifford, Howard C; Dey, Joyoni et al. (2016) LROC Investigation of Three Strategies for Reducing the Impact of Respiratory Motion on the Detection of Solitary Pulmonary Nodules in SPECT. IEEE Trans Nucl Sci 63:130-139
Smyczynski, Mark S; Gifford, Howard C; Lehovich, Andre et al. (2016) Modeling the respiratory motion of solitary pulmonary nodules and determining the impact of respiratory motion on their detection in SPECT imaging. IEEE Trans Nucl Sci 63:117-129
Pretorius, P Hendrik; Johnson, Karen L; King, Michael A (2016) Evaluation of Rigid-Body Motion Compensation in Cardiac Perfusion SPECT Employing Polar-Map Quantification. IEEE Trans Nucl Sci 63:1419-1425
Mukherjee, J M; Lindsay, C; Mukherjee, A et al. (2016) Improved frame-based estimation of head motion in PET brain imaging. Med Phys 43:2443
Dey, Joyoni; Segars, W Paul; Pretorius, P Hendrik et al. (2015) Effect of Non-Alignment/Alignment of Attenuation Map Without/With Emission Motion Correction in Cardiac SPECT/CT. IEEE Trans Nucl Sci 62:1813-1824
Dasari, Paul; Johnson, Karen; Dey, Joyoni et al. (2014) MRI Investigation of the Linkage Between Respiratory Motion of the Heart and Markers on Patient's Abdomen and Chest: Implications for Respiratory Amplitude Binning List-Mode PET and SPECT Studies. IEEE Trans Nucl Sci 61:192-201
Dasari, Paul K R; Shazeeb, Mohammed Salman; Könik, Arda et al. (2014) Adaptation of the modified Bouc-Wen model to compensate for hysteresis in respiratory motion for the list-mode binning of cardiac SPECT and PET acquisitions: testing using MRI. Med Phys 41:112508
Könik, Arda; Connolly, Caitlin M; Johnson, Karen L et al. (2014) Digital anthropomorphic phantoms of non-rigid human respiratory and voluntary body motion for investigating motion correction in emission imaging. Phys Med Biol 59:3669-82
King, Michael A; Dey, Joyoni; Johnson, Karen et al. (2013) Use of MRI to assess the prediction of heart motion with gross body motion in myocardial perfusion imaging by stereotracking of markers on the body surface. Med Phys 40:112504

Showing the most recent 10 out of 27 publications