This work aims to develop and evaluate new tools for non-invasive analysis of white matter fiber bundles in the brain. Diffusion weighted magnetic resonance imaging (MRI) provides information on fiber orientation because the diffusion of tissue water is faster parallel than perpendicular to axons. In addition, the diffusion measurement is sensitive to cellular properties such as cell type, size, and volume fraction. Diffusion tensor imaging (DTI) has been widely used to assess white matter development and pathology, as well as to reconstruct fiber paths in the brain. However, it has become clear that the technique has two major limitations. First, image noise produces both noise and bias in the estimated diffusion tensor. This complicates comparisons of DTI parameters between subjects, and leads to errors in estimated fiber paths. Second, conventional DTI is based on the assumption that a single tensor describes the diffusion in each image voxel. The single-tensor model is inappropriate in regions of the brain with complicated fiber structure (e.g., crossing or splaying fibers). An alternative method, 'q-space' imaging, can be used to quantify diffusion using very few assumptions, but requires impractically long scans for most clinical or pediatric studies. Extended q-space experiments show that the single-tensor model is generally inappropriate, but at present there are no established alternatives suitable for routine clinical use. The studies in this proposal aim to evaluate and mitigate the effects of noise and partial volume averaging in DTI. Specifically, we propose the following: (1) to test theoretical predictions of the effects of noise on the diffusion tensor and estimated fiber paths, and to quantify the performance of a tensor denoising algorithm. (2) To develop high spatial resolution DTI using navigated, multiple shot echo planar imaging. (3) To develop a time-efficient approach to DTI that uses a multiple-tensor model of diffusion in each voxel, and test its reliability in phantom and human studies. (4) To develop approaches to fiber tracking and segmentation using the new multiple-tensor information, and test these in phantom and human subjects. We expect that the resulting methods will significantly improve the sensitivity of DTI studies. Overall this work will help to define the capabilities and limitations of fiber characterization using MRI, which represents a powerful new approach for studying the structure of neural tissue.

Agency
National Institute of Health (NIH)
Institute
National Institute of Biomedical Imaging and Bioengineering (NIBIB)
Type
Research Project (R01)
Project #
5R01EB002777-03
Application #
6929720
Study Section
Special Emphasis Panel (ZRG1-SRB (51))
Program Officer
Mclaughlin, Alan Charles
Project Start
2003-09-01
Project End
2008-07-31
Budget Start
2005-08-01
Budget End
2006-07-31
Support Year
3
Fiscal Year
2005
Total Cost
$237,825
Indirect Cost
Name
Vanderbilt University Medical Center
Department
Radiation-Diagnostic/Oncology
Type
Schools of Medicine
DUNS #
004413456
City
Nashville
State
TN
Country
United States
Zip Code
37212
Choe, A S; Stepniewska, I; Colvin, D C et al. (2012) Validation of diffusion tensor MRI in the central nervous system using light microscopy: quantitative comparison of fiber properties. NMR Biomed 25:900-8
Choe, Ann S; Gao, Yurui; Li, Xia et al. (2011) Accuracy of image registration between MRI and light microscopy in the ex vivo brain. Magn Reson Imaging 29:683-92
Arlinghaus, Lori R; Thornton-Wells, Tricia A; Dykens, Elisabeth M et al. (2011) Alterations in diffusion properties of white matter in Williams syndrome. Magn Reson Imaging 29:1165-74
Xu, Qing; Anderson, Adam W; Gore, John C et al. (2010) Efficient anisotropic filtering of diffusion tensor images. Magn Reson Imaging 28:200-11
Wu, Xi; Xu, Qing; Xu, Lei et al. (2009) Genetic white matter fiber tractography with global optimization. J Neurosci Methods 184:375-9
Hong, Xin; Arlinghaus, Lori R; Anderson, Adam W (2009) Spatial normalization of the fiber orientation distribution based on high angular resolution diffusion imaging data. Magn Reson Med 61:1520-7
Jeong, Ha-Kyu; Anderson, Adam W (2008) Characterizing fiber directional uncertainty in diffusion tensor MRI. Magn Reson Med 60:1408-21
Mishra, Arabinda; Lu, Yonggang; Choe, Ann S et al. (2007) An image-processing toolset for diffusion tensor tractography. Magn Reson Imaging 25:365-76
Anderson, Adam W; Choe, Ann S; Stepniewska, Iwona et al. (2006) Comparison of brain white matter fiber orientation measurements based on diffusion tensor imaging and light microscopy. Conf Proc IEEE Eng Med Biol Soc 1:2249-51
Lu, Yonggang; Aldroubi, Akram; Gore, John C et al. (2006) Improved fiber tractography with Bayesian tensor regularization. Neuroimage 31:1061-74

Showing the most recent 10 out of 13 publications