Current methodologies for 1) quantifying pulmonary blood flow noninvasively with ultrasound and 2) estimating pulmonary input impedance with intraluminal velocity catheters rely heavily on the assumption that the velocity profile in the main pulmonary artery is flat. However, recent studies in humans and animals indicate that the mean profile along the long axis may be skewed toward the anterior wall. This skew has been attributed to flow reversals near the posterior wall during diastole and late systole which become accentuated and extend over a larger portion of the cross sectional area in the presence of pulmonary hypertension. Though attempts to correlate the magnitude and/or duration of flow reversal with pulmonary artery pressure have been made, little is known about 1) the source of the apparent backflow, 2) the effects of elevated flow on the velocity profile, or 3) discrepancies which may occur in impedance related parameters such as characteristic impedance and frequency of the first modulus minimum as a result of intraluminal catheter position. This study will address these issues by evaluating the relationships between velocity profiles and abnormal pulmonary hemodynamics in animal models using an intraluminal 20 MHz pulsed Doppler device. Profiles will be obtained along the long and short axes to create a two-dimensional profile which will be correlated with electromagnetically measured blood flow. Studies performed on the main pulmonary artery will be duplicated on the right pulmonary artery to determine the extent of the flow reversal phenomena as well as the feasibility of using the input impedance of the right rather than the main pulmonary artery to assess pulmonary vascular impairment. Chronic pulmonary hypertension and/or elevated pulmonary blood flow will be created in dogs and lambs. Once control profiles are obtained, the effects of 100% oxygen inhalation and hydralazine will be evaluated. Efforts will be made to improve current methods of measurement by reducing intraluminal probe size and time needed to complete a profile. Findings in the animal models will be compared to patient data. The spectra in the main pulmonary artery, currently being obtained intraoperatively using electromagnetic flow probes, will be compared to the spectra obtained by measuring velocity in the main and right pulmonary artery with a hand-held extraluminal pulsed Doppler probe. Finally, efforts will be made to obtain spectra in the right pulmonary artery whenever studies of the effects of oxygen inhalation are done in the catheterization laboratory to assess vascular tone in patients with abnormal pulmonary hemodynamics.

Agency
National Institute of Health (NIH)
Institute
National Heart, Lung, and Blood Institute (NHLBI)
Type
Research Project (R01)
Project #
5R01HL035389-03
Application #
3349235
Study Section
Respiratory and Applied Physiology Study Section (RAP)
Project Start
1986-06-01
Project End
1989-05-31
Budget Start
1988-06-01
Budget End
1989-05-31
Support Year
3
Fiscal Year
1988
Total Cost
Indirect Cost
Name
University of North Carolina Chapel Hill
Department
Type
Schools of Medicine
DUNS #
078861598
City
Chapel Hill
State
NC
Country
United States
Zip Code
27599
Katayama, H; Henry, G W; Krzeski, R et al. (1996) Pulmonary blood flow profiles with reduced right ventricular function in lambs. Heart Vessels 11:57-63
Katayama, H; Henry, G W; Lucas, C et al. (1995) Blood flow velocity profiles in pulmonary branch arteries in lambs. J Biomech Eng 117:237-41
Katayama, H; Krzeski, R; Frantz, E G et al. (1993) Induction of right ventricular hypertrophy with obstructing balloon catheter. Nonsurgical ventricular preparation for the arterial switch operation in simple transposition. Circulation 88:1765-9
Katayama, H; Henry, G W; Lucas, C L et al. (1992) Three-dimensional visualization of pulmonary blood flow velocity profiles in lambs. Jpn Heart J 33:95-111
Singh, M; Lucas, C L; Henry, G W et al. (1991) Multiangle visualization of flow patterns in saccular aneurysms. Biorheology 28:333-9
Krzeski, R; Long, W; Katayama, H et al. (1991) Hemodynamic effects of endothelin-1 in the newborn piglet: influence on pulmonary and systemic vascular resistance. J Cardiovasc Pharmacol 17 Suppl 7:S322-5
Singh, M; Lucas, C L; Henry, G W et al. (1990) Multiangle visualization of flow patterns in arterial bifurcation models. Biorheology 27:963-70
Lucas, C L; Henry, G W; Ferreiro, J I et al. (1988) Pulmonary blood velocity profile variability in open-chest dogs: influence of acutely altered hemodynamic states on profiles, and influence of profiles on the accuracy of techniques for cardiac output determination. Heart Vessels 4:65-78